Filter Results By:
Products
Applications
Manufacturers
Dissipation Factor
test's dielectric loss to determine quality of insulator.
See Also: Tan Delta Bridges, Tan Delta, Transformers
-
product
Decade Capacitance Box
1412-BC
The wide capacitance range and high resolution of the GenRad 1412-BC decade capacitance box make it exceptionally useful in both laboratory and test shop. Owing to its fine adjustment of capacitance, it is a convenient variable capacitor to use with an Impedance Comparator. The polystyrene dielectric used in the decade steps is necessary for applications requiring low dielectric absorption and constancy of both capacitance and dissipation factor with frequency.
-
product
Decade Capacitor
1419 Series
GenRad 1419-A and GenRad 1419-B (Polystyrene) Owing to its very low dielectric absorption, the GenRad 1419A 3 Decade 1000 pF/step & 1419B 4 Decade 100 pF/step Polystyrene Decade Capacitors are particularly useful in research and development work on computer and integrator circuits and on low-level amplifiers. Its constancy of capacitance and dissipation factor as a function of frequency also makes it extremely useful in measuring circuits and as a component in filters and tuned circuits. High insulation resistance and low dielectric absorption make it the 1419 Decade Capacitor a nearly ideal capacitor for dc work.
-
product
Electrolytic Capacitor Analyzer
13100
Analyzer is a general measurement instrument designed for analyzing the features of electrolytic capacitor s. It has multiple func tions that can be programmed based on the capacitor features by altering the settings to test metal oxidization thin-film withstand voltage, capacitor leakage current, capacitance, dissipation factor, impedance and equivalent serial resistance, etc.
-
product
LCR Meter
The LCR_Meter mini-app macro included with Daqarta allows measurement of inductance (L), capacitance (C), and resistance (R), including Equivalent Series Resistance (ESR) of capacitors. Optionally, it can also show capacitor Dissipation Factor DF or inductor Q.
-
product
Series Standard HV Capacitors
PMT10000
Power Measurement Technologies Inc.
High voltage, low dissipation factor, gas-filled Standard Capacitors for indoor use in a laboratory or production environment. A three terminal design configuration allows accurate measurements of capacitance and dissipation factor (tangent delta) with little or no effect from test lead or stray capacitance.
-
product
Standard Capacitor
1409 Series
The elements used in 1409 Standard Capacitors are selected for low dissipation factor and are stabilized by heat cycling. They are housed in cast aluminum cases, along with silica gel which provides continuous desiccation. These cases are sealed with high-temperature wax. A well is provided in the wall of the case for insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case, and removable banana plugs on the bottom, for convenient parallel connection without error
-
product
Tan Delta And Capacitance Test Set
TDX 5000
TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines.
-
product
Tan Delta Measurement
TD Series
While partial discharge measurement is suitable for detecting electrical trees, tangent delta measurement – also referred to as dissipation factor measurement – detects water trees which have formed in the insulation of the device under test.
-
product
Tan Delta Test Set
TD 5000
The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range.
-
product
12 kV Insulation Fluid Test Cell
CP TC12
The CP TC12 oil test cell is for determining the relative permittivity, the dissipation factor and the power factor of insulating liquids such as transformer oil.
-
product
Capacitance Bridge
TCB-108
Model TCB-108 - Capacitance Bridge is a general purpose bridge for measurement of capacitors, capacitance of transformers and dielectric material. It comprises a transformer-type bridge operating from an internal 108 Hz generator(for accurate measurement at 60Hz) with digital readout of capactiance from 1 pF to 99.999 pF over four ranges and digital readout of D (dissipation factor) in percentage from 0-50%.
-
product
Dielectric Constant (DC) and Dissipation Factor (DF)
Dielectric Constant is used to determine the ability of an insulator to store electrical energy. The dielectric constant is the ratio of the capacitance induced by two metallic plates with an insulator between them to the capacitance of the same plates with air or a vacuum between them. Dissipation factor is defined as the reciprocal of the ratio between the insulating materials capacitive reactance to its resistance at a specified frequency. It measures the inefficiency of an insulating material. If a material were to be used for strictly insulating purposes, it would be better to have a lower dielectric constant.
-
product
Digibridge
1659
The GenRad 1659 Digibridge RLC Tester is an easily programmable, microprocessor-based high performance passive component tester. It automatically identifies the type of component under test and measures in the proper range. The result is simple, precise, unambiguous RLC component testing. The GenRad 1659 RLC Digibridge is an instrument for measuring primary parameters of inductance (L), capacitance (C) and resistance (R) and secondary parameters of dissipation factor (D) and quality factor (Q). GenRad designed this single compact unit with maximum flexibility and operator convenience in mind. The simple front panel design of the Digibridge requires less effort to operate. Digital display and user friendly control allows test parameters and limits to be set easily.
-
product
Beam Lead Capacitors
Beam lead capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which allow for use in military and aerospace designs. Their robust performance and small form factor provide repeatable performance.
-
product
300 V Battery Analyzer
BA6011
The BA6010 Series battery analyzers measure voltage and resistance of modern battery technologies with high accuracy, resolution, and speed. Additionally, these instruments provide auxiliary measurement parameters inductance, capacitance, dissipation factor, impedance, quality factor, reactance, and phase angle in degrees and radians.
-
product
Capacitors - High Q MNOS Series
Macom Technology Solutions Holdings Inc.
MACOM’s MMI-9000 and 9100 Series Chip Capacitors feature high stand-off voltage and low dielectric loss due to our use of nitride/oxide dielectric layers. Gold bonding surfaces, top and bottom provide ease of bonding and minimum contact resistance. MACOMs high Q MNOS series of capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which are features that produce devices with excellent long term stability.
-
product
Capacitors - Beam Lead
Macom Technology Solutions Holdings Inc.
MACOM’s MMI-9000 and 9100 Series Chip Capacitors feature high stand-off voltage and low dielectric loss leveraging nitride/oxide dielectric layers. Gold bonding surfaces, top and bottom provide ease of bonding and minimum contact resistance. MACOMs beam lead capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which are features that produce devices with excellent long-term stability.
-
product
Industrial 4-20mA Driver
Analog Devices portfolio of leading industrial d/a converters and drivers addresses the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
product
Capacitance & Tan Δ Power Factor Meter 12kV
CAPO-12
The CAPO 12 is a fully automatic Capacitance, Insulation Power Factor / tan δ measuring instrument developed by Raytech Engineers. The self-contained instrument performs measurements of Insulation Power Factor (cos ᵠ), Dissipation Factor (tan δ), Capacitance, Inductance, Excitation, Quality Factor and Power Loss (watts). Measurements can be made up to 12kVAC at variable frequency (from 10Hz to 400Hz).
-
product
VLF Diagnostics System
PHG 80 TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 80 TD. The combination of the PHG 80 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
product
Portable PD Diagnostics System
PD-TaD 60
BAUR Prüf- und Messtechnik GmbH
The PD TaD 60 portable PD Diagnostics system is used in combination with a BAUR VLF generator frida for carrying out partial discharge measurement and location.* Comprehensive 360° cable analysis – with parallel partial discharge and dissipation factor measurement* Time-optimised and safe cable condition evaluation* The lightest and most compact PD measuring device up to 60 kVpeak* Developed for portable use on site
-
product
VLF Testing and Diagnostics Unit
Viola TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR viola TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations:viola: Used for cable and cable sheath testing of electrical equipment and medium-voltage cables up to 35 kV. Another function is insulation testing on electrical equipment. viola TD: Expands the functional scope of viola with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissiation factor diagnostics in one device* High performance and compact* Easy and quick test setup* Automatic testing and diagnostic sequences
-
product
VLF Testing and Diagnostics Unit
Frida TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR frida TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations: frida: Used for cable and cable sheath testing of medium-voltage cables and electrical equipment up to 20 kV. Another function is insulation testing on electrical equipment.frida TD: Expands the functional scope of frida with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissipation factor diagnostics in one device* Easy and quick test setup* Automatic testing and diagnostic sequences* Compact dimensions and lightweight
-
product
VLF Diagnostics System
PHG 70 TD
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
product
Capacitance & Tan-Delta Test System
TD-1
By measuring the electrical properties such as capacitance and Tan-Delta regularly on periodical basis, it is possible to ensure the operational unexpected breakdown. Dissipation factor (Tan Delta) is one of the most powerful off-line nondestructive diagnostic tool to monitor the condition of solid insulation of various high voltage equipment.
-
product
Battery Analyzers
BA6010 Series
The BA6010 Series battery analyzers measure voltage and resistance of modern battery technologies with high accuracy, resolution, and speed. Additionally, these instruments provide auxiliary measurement parameters inductance, capacitance, dissipation factor, impedance, quality factor, reactance, and phase angle in degrees and radians. The BA6010 Series is suitable for characterizing battery chemistries that are responsive to a 1 kHz AC stimulus signal including lead acid, lithium and alkaline type batteries used in consumer products, electric vehicles, power backup, security, and fire alarm systems.
-
product
Automatic Coil Test System
LM Series
Koyo Electronics Industries co., ltd
Models in LM-2100 series equipped with LCR meter are designed to measure inductance and dissipation factor of the coil to which DC current is superimposed. Special circuit is built in to protect the LCR meter from surge voltage. Applied current can be step by step in the remote mode. Voltage application is impossible with the safety cover open.
-
product
6U CPCI Switch Board
CP68302
LinkedHope Intelligent Technologies Co.,Ltd.
CP68302 is compliant with PICMG CompactPCI specification. The switch board is largely applicable to high speed data switching and routing among boards and payloads at the internal of CPCI and ATR chassis. With standard 6U CPCI form factor, the Switch is compatible with ATR mechanical designs. CP68302 is designed with two heat-dissipating solutions: traditional air-cooling and ruggedized conduction- cooling with reliable anti-shock and anti-vibration performance, and excellent heat dissipation capability.
-
product
6U Switch Board
VP68801
LinkedHope Intelligent Technologies Co.,Ltd.
VP68801 is a China local design VPX Switch, compliant with VITA46.0, VITA48, and VITA65 specifications. The Profile of VP68801 is SLT6-SWH-16U20F-10.4.2, which uses Gb Ethernet as control plane and SRIO as data plane. It is mainly applicable to high-speed data exchange and routing among different types of payload boards in a VPX chassis. The switching board is designed as 6U VPX form factor, supporting both traditional air-cooled version and conduction-cooled version. With reliable anti-shock and vibration capability, excellent heat dissipation performance and unique environment protection design, the whole board can be stably operated in the wide temperature environment of -40°C to +85°C.
-
product
6U VPX Ethernet + SRIO Switch Board
VP68803
LinkedHope Intelligent Technologies Co.,Ltd.
VP68803 is 6U VPX Ethernet + SRIO switch board compliant with VITA46 and VITA65 specifications, and is mainly applied for high-speed data exchange and routing between different boards in a VPX chassis. Designed with 6U VPX form factor, VP68803 has excellent performance in thermal dissipation and environment protection.Integrated with Ethernet, SRIO switching and routing, VP68803 has 20 1000Base-BX Ethernet interfaces for control plane, and has 19 x4 SRIO 2.1 ports for data exchange. Therefore, VP68803 realizes internal and external data transmission with comprehensive integration. Besides, VP68803 can be installed in Single-Star Topology and Dual-Star Topology backplanes. These characteristics guarantee the stability and applicability of VP68803.