HC 4000 -
optek
Dedicated to optek turbidity sensors the HC4000 provides high precision signal processing combined with flexible configuration of the measurement setup. Several scales, like FTU or EBC can be selected to display the photometric signal in common units with product and process control.
-
Ferrites India
The tip of the unit detects the field polarity. The magnet surface is placed parallel to the unit tip. Two 1.5V AA battery operated. Power ON Switch activates the sensors and gives visual indication in form of two LEDs placed on the arm of the unit.
-
ENVIROMUX-2D -
Network Technologies Inc
The ENVIROMUX-2D supports 2 external configurable sensors, 5 digital inputs, and 1 output relay for control of external devices. It features 2 USB ports for USB modem, USB flash drive, or USB LCD screen. Linux inside.
-
Bourns
A rotary position sensor translates angular mechanical position to an electrical signal. Rotary position sensors are designed for applications that typically require frequent adjustments. Shaftless designs allow for different engagement mechanisms, such as a customized shaft, a motor control, a human interface adjustment or a mechanical arm position locator. Rotary position sensors can be used in applications where a user needs to control a variable output such as a frequency, speed or volume control. Typical applications include test and measurement equipment, consumer electronics, small engines, robotics, and medical equipment. The Bourns® Model 3382 Series uses resistive technology to sense rotary position.
-
Bourns
A rotary position sensor translates angular positions to an electrical signal. Rotary position sensors are designed for applications that typically require frequent adjustment. Shaftless designs allow for a different engagement mechanisms, such as a customized shaft, a motor control, a human interface adjustment or a mechanical arm position locator. Rotary position sensors can be used in applications where a user needs to control a variable output such as a frequency, speed or volume control. Typical applications include test and measurement equipment, consumer electronics, small engines, robotics, and medical equipment. The Bourns® Model AMS22S Series uses Hall Effect magnetic technology to sense rotary position.
-
Site Sentinel -
Teledyne Gas & Flame Detection
Each system includes a tripod, network HMI, gas detection sensor(s), and alarm warning devices. An optional Sentinel SiteWatch provides remote access to system data via Ethernet or cellular communication. Power to the sensor assembly is supplied by a rechargeable Smart Battery Pack, disposable batteries or directly from HMI. Flexible and expandable, a Site Sentinel network can include up to 32 devices and consist of any combination of wireless and/or wired sensors, one or more HMI panels and optional solar panels. Additional sensors and/or remote alarm stations on tripods can be added as needed to assure widespread alert to site personnel.
-
Inframet
Multi- sensor surveillance systems represent a fast growing group of electro-optical systems of critical importance in both defense and civilian applications. At the same time they are the most expensive groups of electro-optical systems. Most advanced but rarely met multi-sensor surveillance systems are built from a long series of sensors like thermal imager (or two thermal imagers, color VIS camera, low light VIS-NIR camera, SWIR camera, laser range finder, laser designator, laser pointer, illuminator located on a stabilized platform and such systems. Simpler systems built from two-three sensors located on smaller stabilized or non-stabilized platforms are more common.
-
Panasonic Industrial Devices Sales Company of America
Panasonic offers total automation solutions products that include PLCs, human machine interfaces, sensors, static control devices, laser markers, servo motors, temperature controllers, timers, hour-meters, counters, limit switches and other factory automation components.
-
1948 -
Peaceful Thriving Enterprise Co Ltd
*With CE & UKCA Approvals.*Detect voltage from 3V to 28V.*No ground wire or clip required.*Replaceable long-life alkaline batteries included.(Power supply: SUM5 1.5V X 2 pc)*Safe with ECMs, sensors, transducers and air bags.
-
LS Series -
Unholtz-Dickie Corporation
The LS Series Long Stroke Thruster Test Systems are highly regarded as the industry standard for long stroke transient testing. This equipment is used in the design and production test of automotive airbag sensors by leading suppliers of automotive airbags and associative control modules.
-
DIT-1020 -
Laxtronics Instruments & Controls Pvt. Ltd
Digital insulation tester Model No: DIT-1020 is designed to carry out electrical insulation measurement in delicate or sensitive electronic sensors, transducers, modules and assemblies with test voltage of 100 Volts DC, its short circuit current is less than 500uA.
-
Rockwell Automation
Our signal interface products provide signal conversion and electrical isolation between sensors and other field devices and a control circuit. Intrinsic safety modules add Zener diodes, which limit the amount of electrical energy on intrinsically safe circuits.
-
FPL1000 -
Rohde & Schwarz GmbH & Co. KG
In an RF lab, the R&S®FPL1000 family is as indispensable as an oscilloscope or multimeter. It is a single instrument for many measurement tasks. It can be used for spectrum analysis along with highly accurate power measurements for power sensors and analysis of analog and digitally modulated signals.
-
Tempsens Instrument Pvt. Ltd.
Tempsens offers calibration of Non contact temperature sensors i.e. Infrared pyrometers traeceble to both national and international standards. Infrared thermometers can be calibrated at our NABL accredited laboratory, from 0ºC to 2900ºC utilizing state-of-the-art blackbody sources.
-
ICH -
Memmert GmbH + Co.KG
Its excellent temperature and humidity homogeneity positions the climate chamber ICH in the international top league of stability test chambers. Thermal transfer to the interior whether heat or cold is guaranteed through a large-area air jacket on four sides. Thanks to its hermetically sealed interior, the climate chamber ICH does not consume any water once the setpoints have been reached, provided that the door is not opened. Two high-grade platinum temperature sensors with mutual monitoring guarantee interruption-free long-term operation even if one sensor should fail.