Showing results: 811 - 825 of 1315 items found.
-
Model FRI -
Laurel Electronics, Inc
Configured to time periodic events which produce start and stop pulses from 1 s to 199.99 s over a programmed gate time up to 199.99 s. Timing resolution to 0.2 s. Optional data I/O and relays for alarm or control. Six 0.56" (14.2 mm) high digits, 1/8 DIN case.
-
PS501-HRP -
Axiomtek Co., Ltd.
*Input Range: 100~ 240VAC Full Range*Output Voltage:**+5V, 25A**+3.3V, 25A**+12V, 41A**-12V, 0.8A**-5Vsb, 3.5A*MTBF(hours): AT 25°C 100,000h*Safety: CB, CCC, UL, TUV, CE, FCC*Dimensions: 185 x 150 x 86 mm*Compatible with Axiomtek products: AX6156LE/AX61220
-
PCIe-DIO-96C3 -
Acces I/O Products, Inc.
This is a x1 lane PCIe, 96 line digital input/output card with counter/timer capabilities designed for use in high I/O density application requirements. I/O connections are made via four 50-pin header connectors. The card is 12.25 inches long (312 mm) and may be installed in any full-length slot that has x1 lane PCIe.
-
310130102 -
Virginia Panel Corporation
The i2 Micro iCon receiver is a one piece connector capable of holding up to 168 QuadraPaddle contacts. QuadraPaddle modules are molded on .100” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. This i2 receiver is made for crimp contacts. Accessories such as keying pin kits, protective covers, and strain relief are available.
-
RF9 Miniature Rosette -
HBM, Inc
Thanks to its three stacked measuring grids, the miniature SG rosette RF9 is only 5 mm in size. Its small diameter enables it to determine a biaxial stress state with unknown principal stress direction in the most confined space. The SG rosette is therefore particularly suitable for measurements on electric circuit boards or especially small components.
-
EM-1 Econo™ -
Bio-Rad Laboratories
The Model EM-1 Econo UV monitor is a single-wavelength detector for flowthrough monitoring of effluents from chromatographic columns, centrifugation gradients, and other devices. The monitor consists of a control unit and an optics module that includes both 254 and 280 nm filters and a 2 mm pathlength flow cell. Connection is via Luer-Lok fittings for quick, easy changes.
-
2830 ZT -
Malvern Panalytical Ltd
The 2830 ZT wavelength dispersive X-ray fluorescence (WDXRF) wafer analyzer offers the ultimate capability for measuring film thickness and composition. Designed specifically for the semiconductor and data storage industry, the 2830 ZT Wafer Analyzer enables the determination of layer composition, thickness, dopant levels and surface uniformity for a wide range of wafers up to 300 mm.
-
FISCHERSCOPE XDL -
Helmut Fischer AG
Robust instrument suited for coating thickness measurements, even at large measuring distances (DCM, stroke 0-80 mm)Features a fixed aperture and a fixed filterSuitable for structure sizes starting at about 1 mmLarge and spacious measurement chamber with a cutout(C-slot)A programmable stage for automated measurements is availableStandard X-ray tube, proportional counter tube
-
CoolX1800 Series -
Advanced Energy
Access incredible power via a compact supply. The modular Excelsys CoolX®1800 offers 1800 W in a 267 x 127 x 41 mm package (approximately 50% more power than the industry standard). Outputs can be parallel connected for higher currents and series connected for higher voltages (up to 348 VDC).
-
YAV90Q04 -
6TL Engineering
The interface YAV90Q04 permits to connect two YAV90096 boards to one 192-Signal contacts Quadrapaddle module. As the Mini-D 50 connectors let 2 free pins (1 and 26), these pins are interconnected to a test point, with the possibility of be grounded. Cable P/N J6200540: Mini-D-50 to Mini-D-50 IDC connectors with 400 mm flat cable.
-
Shimadzu Corp.
These 50 kN (11,000 lbf) capstan grips are designed specifically for testing the tensile properties of rope with a diameter between 8 and 28 mm (0.31 and 1.1 in). The upper and lower grips incorporate an easy-to-load split drum and the upper grip has a counterweight attached to maintain alignment of the grips with the axis of the universal tester during testing.
-
National Technical Systems
Comparative tracking index (CTI) is used to assess the relative resistance of insulating materials to tracking. The CTI expressed as that voltage which causes tracking after 50 drops of 0.1 percent ammonium chloride solution have fallen on the material. The results of testing the nominal 3 mm thickness are considered representative of the material’s performance in any thickness.
-
innco systems GmbH
Antenna Masts are an integral part of EMC and RF measurement systems. Innco system masts are renowned worldwide as the standard benchmark. Available in manual or automatic, using either pneumatic and or electric driven, the antenna mast design has the capacity to carry antennas of 6kg (MM) and 10kgs (MA) as standard. Higher loads are available upon request.
-
Loma Systems
Designed with packed convenience food, ready meals and small packaged goods in mind, the X5C is LOMA's smallest X-ray system available, with a machine length of 1000 mm and offers excellent Critical Control Point (CCP) protection in the smallest footprint possible - and manufactured under LOMA's Designed to Survive philosophy to provide one of the toughest systems on the market.
-
PGT® -
Wolfgang Warmbier GmbH & Co. KG
Test station for PGT®120 or PGT®120.COMStand with magnetic document holder made of IDP-STAT®-PVC in size A3Dimensions: 1700 x 590 x 730 mm (H x W x D)Power coated steel frameColour: light grey RAL 7035 / yellow RAL 1003