40-630A-022-32/2 -
Pickering Interfaces Ltd.
The 40-630A-022-32/2 is a single 32-channel, 2-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
40-632A-021-48/1 -
Pickering Interfaces Ltd.
The 40-632A-021-48/1 is a single 48-channel, 1-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
ATE Systems
ATE has developed a revolutionary calibration and error correction methodology that can completely eliminate the need for operator intervention. This technology: Eliminates the need to attached calibration artifacts to the instruments. Allows the system to be automatically calibrated at any time without operator intervention. Permits calibration with or without the DUT connected.
-
QT 200 NXG -
Qmax Test Technologies Pvt. Ltd.
QT 200 Nxg a Highly sophisticated ATE, is now available as a desktop unit with the cost, flexibility, and performance demanded by a large number of users in research, design, manufacturing, and repair & maintenance industry. It is a combinational-mixed signal board tester for PCBAs designed to cater the needs of PCB test and repair depots, keeping in mind the changing PCB technology and challenges in testing them offline with the combination of all such complex test methodologies in a single test hardware platform with simple to use graphical user interface software.
-
60-555-027 -
Pickering Interfaces Ltd.
High density double pole matrix capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
40-610A-009 -
Pickering Interfaces Ltd.
The 40-610A-009 is a 8-bank, 8-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
-
ATEC Matrix Corp.
ATEC Matrix Corporation can be your one-stop provider of complete turn-key ATE Systems. With over 15 years in ATE Design, Development and implementation we have the expertise and experience to work with you efficiently to provide whatever level of solution your program requires.
-
60-555-023 -
Pickering Interfaces Ltd.
High density double pole matrix capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
Tabor Electronics Ltd.
The Rack Mount platform of the Lucid signal generator is designed to offer maximum channel density at minimum cost of space. Offering up to 4 phase coherent channels in a 19” 1U box, the rack mount platform is by far the best in its class for signal density. Featuring fast switching speed, superior signal integrity and purity, removable memory card for maximum security, all the necessary modulated signals for analog communication systems, built in LAN and USB interfaces, this platform meets today’s most demanding specifications, needed for ATE and production lines.
-
-
Harwin Plc
ATE Probes, Pogo pins and Contact Pads. Gold-plated, spring-loaded, capable of thousands of cycles. Probes for Automated Test Equipment (ATE). Various height SMT contact pins. Flat SMT contact pads. Spring loaded contacts consist of a plunger (or head), barrel (or body), and a fully encapsulated fine spring, to provide the spring force required to maintain positive contact. All have a high durability, exceeding 10,000 mating cycles.
-
PXI-7901 -
ADLINK Technology Inc.
ADLINK PXI-7901 is a general-purpose (GP) switch module implementing 16-CH independent single-pole double-throw (SPDT) relays (1 Form C). PXI-7901 can connect one input to one output and be used as signal switching and routing for measurement system or ATE. Thanks to its high switching capacity, PXI-7901 can also be used to turn on or turn off devices such as motors, fans, heaters, and lights. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7901, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
N7954A -
Keysight Technologies
The N7954A is designed for automated test equipment (ATE) applications where high-speed dynamic sourcing and measurement is needed.
-
Data Patterns Pvt. Ltd.
Data Patterns' core business for over 20 years has been the development of Automated Test Equipment for critical aerospace requirements. Data Patterns developed a Multi Programmer with associated test automation software in 1994. Christened the DP-800 this product was adopted for the implementation of test rigs for Navigation Platform Test Benches, Engine Test Bed Automation, Cable Harness Test Systems, etc. This product was effectively utilized in the development of test benches required by Indian Space Research Organisation (ISRO) for the Polar Satellite Launch Vechicle (PSLV) and Geo Stationary Launch Vehicle (GSLV). Based on this foundation, the next generation test benches were developed in the cPCI architecture. Presently, Data Patterns develops cPCI based test systems for Laboratory applications as well as VME based test systems for challenging environmental conditions. Examples of test solutions built by Data Patterns are indicated below.