Showing results: 1636 - 1650 of 2443 items found.
-
HH2108 -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.8%). Jumbo LCD display 2000 count, 26mm figure height. Manual Ranging at your choice (30 Range). High Voltage test up to AC 500V and DC 500V. Higher Current test up to 20A AC/DC. Resistance test up to 20MΩ. Erequency test range from 10Hz to 1999Hz
-
Hilkar
Nonlinear loads such as power electronics based equipment and electric furnaces are sources of harmonic currents leading to harmonic distortion, which is one of the most important parameters for defining the power quality. Most of the commercial loads such as personal computers, photocopy machines, power supplies, and compact fluorescent lamps; and industrial loads such as AC and DC motor drives inject harmonic currents into the network that they are connected to.
-
LOM-510A -
IET Labs
The Micro-Ohmmeter has 4 digits, 0.02% basic accuracy and 1 resolution. The 4-terminal kelvin measurement connection minimizes lead resistance errors and 80 dB of ac noise rejection provides rock-steady readings even in noisy locations. The micro-ohmmeter comes with rugged 4-terminal test clips and a large selection of optional probes, clips and fixtures allowing attachment to any low-resistance unknown.
-
SAM-3 -
Macintyre Electronic Design Associa
The SAM-3 is a portable single channel signal conditioneer specifically tailored to provide power to and process the signals from MEDA's line of AC magnetic field sensors. The unit operates from eitherits internal batteries or the power line. It incorporates two sets of power line rejection fileters, switch selectable fro 50 to 60 Hz and the corresponding first four harmonics.
-
PeakTech Prüf- und Messtechnik GmbH
AC/DC-Adaptor in latest eco-friendly-technology. Combined with the wide range of line voltage from 100 - 240 V AC max. output current of 1500 mA and an output voltage of 3 - 12 V DC. With the included plug set of 6 pcs the adapter can be used universal. This powerful adapter is short-circuit proofed, has an automatic thermal fuse and is equipped with an overload protection.
-
FERVE s.a.
FERVE has a new range of products, pure sine wave inverters. These investors next generation transform 12V DC to AC 220-240V, and being pure sine wave can be used in devices with motor, simple, complex or sensitive electronics. Thus, from a battery making energy available to electrical installations, tools, appliances, etc. All it controlled by microprocessor and with high quality performance.
-
CSF-400 -
Power True Systems Corp.
Measuring frequency. Accuracy: +/- 0.05%. 4 Digital display: 9999 Input Max. 400Hz/600 V, 30KHz/12V. Aux. Power AC 115/230V +/-15%, 50/60Hz. Isolation Aux. Power 12Vdc, 24Vdc, 48Vdc, 110Vdc available in option. Easy-to-wire, screw type terminal. Outside dimensions is DIN standard (96mm x 48mm) High stability & low cost.
-
Series DR3P -
Teledyne Defense Electronics Relays & Coax Switch
Series DR3P solid-state relays provide three-phase output, offering both AC and DC control with a zero-cross turn-ON thyristor output. The DR3P provides an integrated heat sink, output transient suppression (MOV and snubber circuit) and LEDs that serve as status indicators for diagnostics. The relays are designed for DIN-rail or panel mounting.Available options include:DR3P48A50 22A, 24-520Vrms Load; 90-240Vac/Vdc
-
NI
PXI Chassis are compatible with PXI, PXI Express, and PXI hybrid modules and meet the cooling requirements of the most power-demanding PXI modules. You can also choose chassis options that minimize the overall system acoustic emissions. Chassis can provide up to 18 slots, with a mixture of both PXI and PXI Express module compatibility, and you can choose between AC and DC power options.
-
Absopulse Electronics Ltd.
At ABSOPULSE Electronics, we specialize in the design and manufacture of heavy-duty custom and semi-custom AC-DC switching power supplies, rectifiers and battery chargers.We can meet any AC to DC input/output configuration requirement, with output power ranging from a few watts to several kilowatts.ABSOPULSE's rugged power supplies are typically designed and built for an operational life of 20 to 30 years in harsh environments.
-
AP1 -
NG Systems Ltd
An add-on board that provides an autopan function to any AC, fixed speed pan and tilt head fitted with limit switches. It functions by monitoring the current flow to the CCTV panning motor and selecting the alternate motor whenever the current ceases (i.e. limit switch is activated). This facilitates simpler wiring to the panning head without the need for additional switches or other components to be fitted to the head.
-
HH2205F -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.5%). 3-3/4 Jumbo LCD display 4000 count with symbolic signs. Auto Ranging High Voltage test up to 1000V DC and 750V TRMS AC. Higher Current test up to 20A AC/DC. Diode and Continuity check. Measure Resistance up to 40MΩ. Measure Temperature up to 760oC or 1400oF
-
ER-Q Series -
Panasonic Industrial Devices Sales Company of America
With Panasonic’s high-frequency AC method and “Sirocco Fan”, the ER-Q Compact Fan Type Ionizer can remove electrostatic charge even at slow fan speeds.ER-Q Ionizers are extremely compact and well suited for removing localized electrostatic charge on manufacturing equipment for electronics or in Semiconductor processes. The ER-Q Ionizers require no compressed air which eliminates air lines and reduces additional maintenance.
-
RX-21b -
Reply S.p.A.
The RX-21 Teslameter is a portable, hall-effect magnetic field meter that measures both the DC component and the AC component of the field. The latter quantity is measured in the frequency range 20 Hz - 25 kHz as the effective value of the magnetic field (so-called true RMS), regardless of changes in the field as a function of time. The meter's operating range is 0 - 3000 mT , switched manually or automatically.
-
RX-21b -
Resonance Technology
The RX-21 Teslameter is a portable, hall-effect magnetic field meter that measures both the DC component and the AC component of the field. The latter quantity is measured in the frequency range 20 Hz - 25 kHz as the effective value of the magnetic field (so-called true RMS), regardless of changes in the field as a function of time. The meter's operating range is 0 - 3000 mT , switched manually or automatically.