Filter Results By:

Products

Applications

Manufacturers

AC

Current Alternates direction of flow cyclically.

See Also: Alternating Current


Showing results: 1831 - 1845 of 2483 items found.

  • Audio Multimeter

    AMM-1 - D'Amore Engineering llc

    The purpose of this tool is to enable the user to: Measure True Amplifier Power output into any load reactive or resistive Measure Common DC voltages Measure DC voltage drops during quick transients on cable runs or battery / charging systems Measure Impedance of speakers at any power or frequency from 20Hz - 1kHz (box rise) Measure Phase Difference between Voltage and Current into reactive loads (Power Factor) Find Tuning Frequency of subwoofer enclosures Tune subwoofer enclosures for maximum power transfer Measure AC Volts (amplifier output) Measure AC Amps (amplifier output)

  • FC(Fuel Cell) Impedance Measurement System

    KFM2150 System - Kikusui Electronics Corp.

    The KFM2150 system is a fuel cell impedance measurement system configured with an FC impedance meter KFM2150 and an electronic load PLZ-4W series. Combination of KFM2150 and PLZ-4WA series (0V input type) supports impedance measurement for single cell of fuel cell.In addition to impedance measurement with AC impedance method, KFM2150 system provides IR measurement with current interrupt method.Application software enables test for each characteristic of fuel cell such as I-V characteristics, Constant Current characteristics, Current Interrupt method and Cole-Cole plot by the AC impedance method. Moreover, each test can be performed in a specified order.

  • High-Voltage Power Supply / Amplifier / Controller

    Model 610E - TREK, INC.

    The Trek Model 610E is a high-voltage power supply / amplifier / controller that is used in many applications including closed-loop charge control, electrophotographic research, insulation testing, dielectric material evaluation, and as an amplifier for AC or DC calibrators and power supplies.

  • Digital Signal Generator

    MCH Instruments Co.,Ltd.

    Digital Signal Generator*signal frequency:0.1Hz~2MHz, continuously variableave from: square, sine*output attenuator: 0dB,, 20dB, 40dB, 60dB*output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*rising and falling edge of square not more than 35ns,*sine distortion less than 1%, amplitude –frequency characteristic : ±0.5dB within 100KHz, ±1dB above 1MHz*frequency meter: 10Hz~30MHz*power supply : AC 220V(110V optional)

  • Digital to Synchro and Digital to Resolver Converters

    Computer Conversions Corporation

    1.2VA, 1.5VA, 4.5VA and 5VA Models60 or 400, & 60 and 400 Hz. Models to 22 KHz.Trouble Free Isolated Reference Inputs & Signal OutputsUltra High Efficiency, Low DistortionSelf Powered off the AC Reference Input (DSP Series)Internal Cool AC-Pulsating Supplies (DSP Series)Very Low Loss & Heat DissipationFULLY INTEGRATED, NO EXTERNAL COMPONENTS REQUIREDVery High Resistance to Shock and VibrationHigh Reliability Throughout ImplementationIsolated, Transient, Therrnally & Short Circuit Protected Outputs

  • Electrical Standards

    Fluke Calibration

    To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.

  • Hand-hold Field Intensity Meter

    LM870-H - Sichuan Jiuzhou Electronic Technology Co.,Ltd

    * Trunk-line AC voltage, V/A, C/N and TILT measurable* Automatic over-voltage shut-off protection* AC/DC optional (Ni-H/Li storage battery inside)* Full-digital key-board operation, direct freq. & channel input* Automatic scanning, Automatic channel-filtering, Automatic error-operation amending* All standard channels and subjoin channels pre-set inside* New channel-table setting according to user's special requirement* Character LCD displaying* English/Chinese operation interface* Audio output (speaker set-in)

  • Portable AC/DC Power Supply

    UPS S3 - Manta Test Systems

    The Vanguard UPS S3 is an AC/DC adjustable output power supply designed to operate substation circuit breakers. The UPS S3’s AC and DC voltage sources can supply up to 10 Amperes during the circuit breaker coil energization and circuit breaker charging motor operation. Powered by a single phase 90-120 Vac voltage source, the UPS S3 provides an isolated adjustable AC/DC voltage source. Output voltages are variable via the front panel control knob.

  • Portable Multimeter

    Nanjing ELIKE Meter Co, Ltd.

    Basic functions:DC current: 200μA/20/200mA/10A AC, voltage: 200/600V DC, voltage: 200mV/2/20/200/600VResistor: Rx200/Rx2/Rx20/Rx200K/Rx2MSpecial functions:Diode transistor testContinuity buzzer low battery displayNegative polarity displaySelf-recovery protectionSampling frequency: 3 times/sMaximum display: 1999General characteristics:Product colors: iron-gray and orangeProduct net weight: approximately 115gLCD size: 53x33mmProduct size: 133x70x30mmPower: 1x9VPacking contents:Packing cartonHandheld bag English manualTesting lead batteryStandard individual packing carton size: 153x101x34mmCarton size: 560x325x340mm

  • Power RC Snubbers

    HK Film Capacitor Ltd

    Single phase and Three phase availableSuitable for AC and DC voltage applicationResistance and rate power of Resistor : 1 - 50W ( can be customized to 100W or above )Voltage: 63Vac, 125Vac, 280Vac, 480Vac, 500Vac, 600VacOperating temperature : -25~+85C / -40~+105CTesting Voltage : : 1.5 x Un 10sec ( can be customized )Varistor and Diode options available. Different applications can have very different electrical and mechanical profile requirements.Please feel free to send your application details for a suggestion and quotation.

  • PPS Clamp Transformer

    Techimp HQ S.r.L

    PPS2 provides power supply to the PD detectors installed on HV cable when low voltage AC power is not available. The PPS2 takes the required power directly from the High Voltage power line under monitoring by means of units clamped on the HV power cable(s).PPS2 is designed to withstand High Voltage line failure events such as temporary overload and short circuit conditions. An internal detection and self limiting circuitry guarantees that PPS2 and the connected equipment survives in case of such events.

  • Ultra Low Noise Preamp

    J2180A - PICOTEST Corp.

    The J2180A low noise preamplifier provides a fixed, AC coupled 20dB gain while converting a 1 MOhm input impedance to a 50 Ohm output impedance. With a 3dB bandwidth of 0.1Hz to 100MHz, the preamplifier improves the sensitivity of oscilloscopes, network analyzers and spectrum analyzers while reducing the effective noise floor and spurious response. The preamplifier can also serve as a low frequency DC blocker for a spectrum analyzer or you can use it to connect a high input impedance oscilloscope probe to 50 Ohm equipment.

  • 3 3/4 Digits AC/DC Current Digital-Clamp Multimeter

    KT7193 - Ketai instrument (kunshan) Ltd.

    ● 3 3/4 digits 3999 count● Extra high DC/AC current measurement● Data hold to capture measurements● Backlit display is easy to read under any light condition● AC current measurement up to 1500A● DC current measurement up to 1500A● DC/AC voltage, resistance, capacitance, frequency and temperature measurement● Diode and continuity test● Accessories included: 9V battery, carrying case, test leads, K typetemperature probe, English manual, gift box

  • Fan Type Ionizer

    ER-F - Panasonic Industrial Devices Sales Company of America

    With a compact size of 150 x 166 x 62mm and a fan of 120mm in diameter, the ER-F Fan Type Ionizer belongs to the leading class of compact Fan Type Ionizers. The system employs a high-frequency AC method and boasts a +/-2kV discharge output voltage that discharges electrostatic contaminated objects quickly and safely. Louvers for long distance and wide area applications are shipped with the Ionizers. Standard fan types for faster charge removal times and low-volume types for discharging small parts or film are available.

  • Battery DC Resistance Analyzer

    KT-2004 - KILTER ELECTRONIC CO.,LTD

    ●DC pulse measure mode like battery real working state ●Special benefit to test online UPS battery with fluctuation charger●Effective eliminate the AC power supply with stable and accurate reading●Test range:200mΩ/2Ω/20Ω/200Ω●Max resolution:0.1mΩ●4 wire measurement●Voltage range:0.01V~19.99V●For Lead -acid,Lithium,Li-ion,Ni-HM and other types of batteries used ●Special benefit to online UPS battery with fluctuation charger

Get Help