  • 2000 A AC/DC Utility Clamp Meter

    FLIR CM94 - Teledyne FLIR

    The FLIR CM94 tackles high-current measurements on demanding utility and industrial job sites. This rugged meter securely clamps larger conductors with an oversized jaw so you can take readings up to 2000 A AC & DC. With a CAT IV-1000 V safety rating, the CM94 is ready to work on overhead, underground and utility service equipment. Plus, it offers VFD mode to tackle noisy signal environments. The full-featured FLIR CM94 utility clamp meter delivers results for utility and industrial electricians.

  • Non-contact Voltage Tester

    Eclipse Tools

    Built-in white LED illumination light provides convenient work in dark areasDetects AC voltage from 90 to 1000 VAC without metallic contactCompact size with pocket clip easily fits into pockets or tool pouchesRed LED and audible alarm if voltage is presentEntire outer surface is non-conductive for safety, helps avoid high voltage shockPowered by two 1.5V AAA batteries (not included)CAT IV 1000V Safety rating.Applications: Electricians, maintenance staff, service and safety personnel, and even homeowners

  • PXI 8 x DPDT Power Relay Module, 5A

    40-157-001 - Pickering Interfaces Ltd.

    40-150/151 modules have 8xDPST or 12xDPST power relays, suitable for switching inductive/capacitive loads up to 5A at 250VAC. 40-155/156 modules have 8xSPDT or 16xSPDT power relays and 40-157 is configured as 8xDPDT. Power relay modules are intended for switching heavy AC or DC loads or for slave switching large external relays, contactors and solenoids. The 40-150 series of power relay module are suitable for applications requiring switching of either mains voltage or DC current.

  • TMR Current Sensors

    MultiDimension Technology Co.,Ltd.

    An open-close current transducer, high sensitivity and signal-to-noise ratio TMR chips are used in the design, which based on Tunneling magneto resistance effect. The transducer has a built-in temperature compensation and nonlinear compensation circuit, which can accurately measure DC, AC and pulse current. The transducer has many benefits ,such as high precision, wide bandwidth, low power consumption, excellent isolation performance and so on. Besides, the design of open-close structure makes it easier to install and unload.

  • 8x4 Power Matrix, 2-Pole, 2xGMCT

    40-550-902 - Pickering Interfaces Ltd.

    This version of the 8x4 power matrix is for heavy current/low duty cycle power switching. Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current.

  • Dielectric Loss Tangent Testing Instruments

    Soken Electric Co. Ltd

    Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.

  • CO2, Humidity and Temperature Datalogger

    Extech SD800 - Extech Instruments Corporation

    SD800 monitors air quality in schools, office buildings, greenhouses, hospitals and anywhere that high levels of carbon dioxide are generated. Selectable data sampling rate of 5, 10, 30, 60, 120, 300, 600 seconds or automatic. Maintenance free dual wavelength NDIR (non-dispersive infrared) CO2 sensor. Triple LCD simultaneously displays CO2, Temperature and Relative Humidity. Complete with six AAA batteries, 2G SD memory card, universal AC adaptor, and mounting bracket.

  • Power Meters

    Chroma Systems Solutions, Inc.

    Chroma’s Digital Power Meters are designed for both single-phase and multiple phase measurements of AC power signals and related parameters common to most electronic products. Instead of traditional analog measurement circuits the 66200 Digital Power Meter uses state-of-the-art DSP digitizing technology. The internal 16 bits analog/digital converters with sampling rates of up to 200KHz provide both high speed and high accuracy measurements which is unprecedented within the industry for this class of power meters current on the market.

  • 3-Phase Power Analyzer/Datalogger - up to 30,000 Sets of Measurements

    Extech PQ3450 - Extech Instruments Corporation

    The PQ3450 is a 3-phase power analyzer/data logger capable of logging up to 30,000 sets of measurements in Excel format on a removable SD memory card. The product is easy-to-hold with a rugged over molded housing and features a built-in clock and calendar, 35 parameters and a CAT III 600V safety rating. Complete with a year warranty, 4 voltage leads with alligator clips, 8 AA batteries, SD card, 100-240 Volt AC adaptor and case. Clamp probes sold separately.

  • External Input Module

    EIM-01 - Compact Power Company

    The EIM-01 external input module is used to safely isolate and input an external drive signal into the MAC-01, -02 or -03 AC Power Sources/Frequency Converters. The unit can accept various waveforms from laboratory or programmable oscillators or from a Titan MOS-01, -01A, -01B when used as a slave unit in multi-KVA systems. BNC input is completely isolated and floating with 1,500VAC breakdown and excellent common mode rejection. A recessed 8% gain adjustment control is also provided. The EIM-01 must be factory installed.

  • Electrical Tester For Voltage

    PDT35 - Pyle Audio Inc.

    Automatically Selects VAC, VDC, or Continuity TestComplies with EN 61010-1 For Use in CATIII 600 V Environments1999 Count LCD DisplayAuto Power On/OffHigh Input Impedance -- 400 kVoltage AC: Max Range 600 V, Accuracy +/- 1.5%Voltage DC: Max Range 600 V, Accuracy +/- 3.0%Continuity TestAccessories Included: Test Leads, 2 'AA' BatteriesDimensions: 8.46' H x 2.83' W x 1.44' DWeight: 8.29 oz.Sold as : Unit

  • Earth/Ground Resistance Tester

    DE-5030 - DER EE Electrical Instrument

    Earth resistance range0~12 / 0~120 / 0~1200 Normal operation conditionsBattery voltagein range of "BATT.GOOD" Earth voltage measurementmax. AC 30V Output current3mA Response timewithin 1 sec. Insulation resistancemin. 100M / DC1000V between input terminals and case Withstand voltageAC3700V (50 / 60Hz) for 1 min. between input terminals and case Battery Check Battery1.5V x 4 Safety standardIEC 61010-1 CAT.III 300V IEC 61557, IEC61010-031

  • F Series Panel Meter

    ST-120 - Standard Electric Works Co., Ltd

    ● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.

  • F Series Panel Meter

    ST-70U (Four studs mounting) - Standard Electric Works Co., Ltd

    ● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.

  • F Series Panel Meter

    ST-123U - Standard Electric Works Co., Ltd

    ● Hz Meter : Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz Rated Voltage : 110V, 220V Accuracy : Class 2.0 Consumption : Max. 15mA Test Voltage : 2kV. 50-60 Hz● Case and Composition: Polycarbonate front and Polybutylene Terephthalate(PBT). Three studs mounting.● Accuracy : AC class 2.5 DC class 2.0 Rectifier class 2.0● Color:Black case and white scale plate.● Pointer:Sword type color in black.