  • Arc Ingintion Tester

    SCR ELEKTRONIKS

    The product is designed to carry out Arc Ignition Test as per IS/IEC 60947-1 Clause 8.2.1.1.2 (material used for electrical products). The adjustable current source is 230V AC @ 33A. The load is adjusted to get 32.5A at 0.5 power factor. Included on control unit are Digital Voltmeter, Digital Ammeter, Digital Power Factor Meter and Micro Controller based programmable Sequence Timer with LCD display for display & setting. The arrangement is made to mount the test piece with electrodes as per the specification given in the standard.

  • PXI Solid State Matrix Module, 6x2, 30 A

    40-554B-011 - Pickering Interfaces Ltd.

    The 40-554B-011 is a high current 6x2 matrix occupying two PXI chassis slots. Each matrix crosspoint uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each matrix switching path can support 30A of continuous current and switch up to 40V signals. The switches can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid-State Matrix Module, 6x2, 10 A

    40-553A-011 - Pickering Interfaces Ltd.

    The 40-553A-011 is a high current 6x2 matrix occupying two slots of PXI chassis. Each matrix crosspoint uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each matrix switching path can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • Digital (1kV below) Insulation Tester

    2151 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● 68 × 34mm(2.677” × 1.338”) large LCD display.● 3½ digital LCD(2000 counts) a LCD indicated instrument for insulation.(MΩ), continuity(Ω) and AC voltage.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA DC load.● >200mA short circuit testing current for a resistance tests.● Auto ranging.● REL function.● Auto power OFF.● Fuse protection.● Auto data hold.● BS 16 edition.

  • Lightning Surge Generator

    SKS-0506IB - Shanghai Sanki Electronic Industries Co., Ltd.

    The lightning surge generator SKS-0506IB1 fully complies with the new standards of IEC61000-4-5, EN61000-4-5 and GB/T17626.5; provides a pulse test voltage of up to 6kV; both AC and DC samples can be tested , subject to The rated voltage of the test equipment can reach 400V, and the rated current of the three-phase equipment is higher than 32A; 7-inch color LCD touch screen, friendly human-computer interaction interface, more intelligent and more user- friendly operation; the software is built in the IEC standard Level mode can be directly called.

  • 4U 5-Slot CompactPCI® Chassis with 400 W Power Supply

    cPCIS-6400X Series - ADLINK Technology Inc.

    The cPCIS-6400U/6400X Series subsystems are designed for 6U cPCI boards with 80mm RTMs. The chassis is 4U in height and standard 19" rack mount width. The cPCIS-6400U provides 2+1 hot swappable 500W+250W redundant power supplies with universal AC input, while the cPCIS-6400X has a built-in 400W AC-input ATX power supply with cooling fan. Both series have PICMG 2.1 Hot Swap compliant 32/64-bit 5-slot CompactPCI backplanes and a PICMG 2.5 H.110 CT Bus.

  • Variable Power Supply

    VS-10a - Allied Edison LLC

    The VS-10a power supply is a light weight, portable, non-isolated “variable source” from 0 volts to 150 Vac or 0 volts to 150 Vdc and rated for up to 10 amps, thus the name VS-10a. It is comprised of an illuminated voltmeter that reads to the first significant digit, AC variable system output voltage, DC variable system output voltage, logic output voltage and one sense (continuity) contact monitoring points. Banana jacks for connection of test leads are spaced at intervals that allow the use of dual banana test plugs if desired. The VS-10a is protected by two levels of overcurrent protection; AC input, and ground fault protection by a GFCI. All circuitry is housed inside a custom designed case made from 16 gauge steel. An Internal fan dissipates heat buildup and exhaust through louvered side vents built into the case. The carrying handle is designed with a “spring return to rest” position and is padded for comfort. The case has been sized for optimum portability and is balanced from the handle during transportation. The case has a powder coated finish that is scratch, chemical and weather resistant. Rubber padded feet support the case when in the upright position and a convenience receptacle is located on the side of the case.

  • Triple Alarm CAT IV Non-Contact Voltage Detector with Flashlight

    FLIR VP50-2 - Teledyne FLIR

    The FLIR VP50-2 is a durable, CAT IV-rated non-contact voltage detector featuring light, vibration, and beeper feedback alarms and a powerful LED flashlight. Use the VP50-2 to reliably check if an AC circuit is live before beginning work; detect voltage on exposed conducting parts or through insulation; identify live wires within electrical panels, switches, and outlets; or trace live wires and map circuits. With an ergonomic and drop-tested design, the FLIR VP50-2 is the right choice for professionals performing field troubleshooting and verification of electrical installations within residential, commercial, and industrial buildings.

  • Time-Resolved Electrochemical Quartz Crystal Microbalance

    400C Series - CH Instruments, Inc.

    The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).

  • Winding Resistance Meters

    Neutronics Manufacturing Co.

    The NMC 'TDR' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. 'TDR' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. 'TDR' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.

  • Single 8x2 1-Pole 16 Amp PXI Power Matrix

    40-552-002 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Single 4x4 1-Pole 16 Amp PXI Power Matrix With Loop-Thru

    40-552-011 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • Single 8x2 1-Pole 16 Amp PXI Power Matrix With Loop-Thru

    40-552-012 - Pickering Interfaces Ltd.

    The 40-552 range of 16 Amp PXI power matrix modules is available in four configurations with matrix sizes of 8x2 and 4x4 and the ability to expand the matrix size with the Y-Axis loop-thru connections: e.g. 8x4, 12x4, 16x4, etc. (with 4x4 matrices) or 16x2, 24x2, 32x2, etc. (with 8x2 matrices). This range is capable of switching up to 16 Amps and up to 300VDC/250VAC hot switching and 400VDC/250VAC cold switching. These PXI power matrix modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors, and solenoids.

  • PXI 8x4 1-Pole 10A Matrix With Loop-Thru

    40-551-101 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, this module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. This version of the 40-551 may be expanded to larger matrix sizes using cabling to daisy-chain the X and Y signals Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • PXI Single 6-Channel 30A Solid State MUX

    40-667-012 - Pickering Interfaces Ltd.

    The 40-667 is a high current multiplexer available in dual 3-channel or single 6-channel configurations occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 30A of continuous current and switch up to 40V signals. The switches can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.