Filter Results By:

Products

Applications

Manufacturers

Acoustic

the study of sound.

See Also: Sound, Ultrasound, Audio, Infrasound, Reverberation, Acoustical, Bioacoustic, Audio Test Systems


Showing results: 376 - 390 of 416 items found.

  • Decibel Meters

    PCE Instruments

    A decibel meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the device and acoustic measurement values are displayed. Here at PCE Instruments, we offer two types or classes assigned to decibel meters: type 1 / class 1 or type 2 / class 2. For assessing noise in basic industrial, commercial, educational, recreational or residential applications, a type 2 / class 2 decibel meter usually will suffice. For precision-grade assessments often made in a laboratory, a type 1 / class 1 sound level meter primarily is used.

  • Hydrophone

    TC4047 - Teledyne Marine RESON B.V.

    The TC4047 miniature hydrophone offers a useable frequency range from 1kHz to 170kHz. The hydrophone incorporates a high quality 20dB low-noise pre-amplifi er which provides optimal conditions for signal transmission. The high sensitivity provides excellent signal to noise ratio and immunity against induced cable noise. The hydrophone is omnidirectional up-to 100kHz and has uniform receiving characteristic from 1kHz to 100kHz. An insert calibration circuit enables remote testing of the hydrophone condition. The hydrophone comes with a SEACON connector. The sensor element is permanently encapsulated in Special formulated NBR to ensure long term reliability. The rubber has been specially compounded to ensure acoustic impedance close to that of water. The strainrelief and outer jacket of the cable is made of high density polyurethane. TC4047 can be used in sea or fresh water.

  • Dynamic Signal Analyser

    ADLINK Technology Inc.

    Dynamic signal analyzers provide highly accurate measurement and analysis, and are widely used in audio testing, acoustic measurement, environmental noise testing, vibration analysis, NVH measurement, machine condition monitoring, and rotating machinery evaluation. ADLINK's dynamic signal analyzer series features 24-bit analog-to-digital converters (ADCs) with sampling rates up to 432 kS/s for PXI, PCI, and USB platforms for flexible yet accurate measurement supporting high performance and cost-effectiveness in a wide variety of testing applications.

  • Mobil Cable Test and Fault Location System

    SWG-12 (SWG-32) - Kharkovenergopribor Ltd.

    • testing cable insulation with DC (rectified) voltage up to 32 kV;• conditioning faults by burning faulty cable insulation with current up to 100 mA;• pre-locating cable faults with the reflectometer RIF-9 based on the pulse reflection method (TDR), voltage wave oscillation method (DECAY), impulse current envelope (ICE) method and arc reflection method (ARC / ARC multi-shot);• pinpointing cable faults with the acoustic method with up to 2000 J surge wave generator and a suitable signal receiver.

  • Surge Voltage Generator

    SSG 2100 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 2100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit

  • Surge Voltage Generator

    SSG 1100 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 1100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit

  • Surge Voltage Generator

    SSG 1500 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 1500. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit

  • Electret Measurement Microphone

    EMM-6 - Dayton Audio

    The EMM-6 is a precision electret condenser microphone designed for measurement and critical recording applications. The extremely flat frequency response and true omni-directional polar pattern make it perfect for use with room acoustic analyzers and audio measurement systems. The EMM-6 microphone is individually hand calibrated using a laboratory standard Brüel & Kjær microphone in conjunction with a DAAS computer measuring system. Each microphone includes stand mount, foam windscreen, transport case, and its own unique calibration response graph.

  • Surge Voltage Generator

    SSG 3000 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 3000. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* high surge energy in each voltage range

  • Network Tester

    PeakTech Prüf- und Messtechnik GmbH

    Compact 3½-digit multimeter, developed according to the CAT III 600 V standard with integrated LAN network tester. In addition to the extensive measurement functions for voltage, current and resistance, this model has a fast-reacting continuity test with an acoustic signal and the possibility of performing diode tests. This combination measuring device is a very practical test device that easily shows the correct pin assignment of network cables by comparing a transmitter with the corresponding cable receiver using an LED. Trouble-free checking of cable passage, open, short and cross connect is possible.

  • Stand-Alone Doppler Current Sensor

    DCPS - Aanderaa Data Instruments AS

    The Doppler Current Profiler Sensor (DCPS) is a medium-range, 600kHz current profiler smart sensor. It offers high-quality ocean current measurements and is ideally suited for cabling directly to various systems or dataloggers via serial or AiCap bus. With its integrated compensation for tilting and movement, the sensor is commonly used to measure current from buoys and other moving platforms.The 5400/5400R version of the current sensor is 300m depth rated, the 5402/5402R version is 4500m depth rated, and the 5403/5403R version is 6000m depth rated and intended for commercial as well as research use. It comes with an integrated temperature sensor that can be calibrated on request.As an extension to the DCPS, we now offer the current profiler with an integrated pressure unit called the 5400P. This version enables acoustic wave measurements in addition to profiling currents. Ideal for small observatories, the DCPS sensor is the market's lowest-cost current and wave sensor.

  • Time-Resolved Electrochemical Quartz Crystal Microbalance

    400C Series - CH Instruments, Inc.

    The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).

  • Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT

    PDMonitor - Power Monitoring and Diagnostic Technology Ltd.

    The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.

  • Hydrophone

    RESON TC 4032 - Teledyne Marine RESON B.V.

    The TC4032 general purpose hydrophone offers a high sensitivity, low noise and a flat frequency response over a wide frequency range. The high sensitivity and acoustic characteristics makes TC4032 capable of producing absolute sound measurements and detecting even very weak signals at levels below “Sea State 0”. The TC4032 incorporates an electrostatically shielded highly sensitive piezoelectric element connected to an integral low-noise 10dB preamplifier. The TC4032 preamplifier is capable of driving long cables of more than 1.000 meters, and the preamplifier features an insert calibration facility.

  • Industrial Vibration Sensor

    IVS-500 - Polytec GmbH

    The new IVS-500 Industrial Vibration Sensor is the key to fast acoustic quality inspection, structure-borne noise analysis and reliable pass-fail decisions. This Laser sensor measures reliably, in demanding industrial environments, without contact and therefore without wear and on virtually all surfaces. Costs and yields are therefore optimized by reducing false rejects in the production and assembly process. The simple setup and ruggedized sensor design of the IVS-500 enable a smooth integration into production test systems. Complemented with the software tool QuickCheck, Polytec offers a comprehensive solution for reliable pass/fail analysis.

Get Help