  • Earth Contact Resistance Tester

    SCR ELEKTRONIKS

    SCR ELEKTRONIKS have developed an equipment namely Earth Contact Resistance Tester to test the appliance. To ensure the safety of operator it is essential that the Earth path (connection) should offer minimum impedance to by pass short circuit Current to Earth. This is ensured by measuring Resistance of the Earth path by passing heavy Current say 25 A. The Earth Contact Resistance Tester essentially comprises of a Variable Current source with digital Ammeter to measure the Current supplied. The Voltage drop across the Earth path is measured with a digital Voltmeter. Optionally for a particular Current (25 A) the meter can be calibrated in terms of Resistance. A timer is provided to switch off the Current after the Set Time.

  • Active Switching Power Supply Using Mosfet, 125 KW, P/N 5940C2

    Carl E. Holmes Company

    - Active Switching Power Supply Using MOSFET, 125 KW, P/N 5940C2- Input: 480 VAC, 150 Amps, 3 PH, 60 Hz- Output: 0 to 50 VDC, 2500 Amps max- Ten modules in parallel, each module is rated for 0 to 50 VDC, 300 Amps- PLC Control provides Positive Polarity, Negative Polarity and Shuts OFF- Start / Stop capability and EPO- Output voltage and current are displayed on the voltmeter and ammeter- PLC supplied by the customer. We provide a PLC interface only- Indoor enclosure dimensions: 65″W x 50″H x 36″D or (TBD)- Estimated weight: 2000 lbs. or (TBD)

  • 12V Automatic Battery and 12/24V Electrical System Analyzer

    6044 - Associated Equipment Corp.

    • Easy-to-read LED voltmeter and ammeter• 500 amp safety clamps with “Flexi-Spring” and patented side terminal adapters• Separate 6 ft. high impedance test leads with alligator clips for tight spots• Cart / Printer can be purchased separately – Cart Model 6038C, Printer Model 6041• Automated testing of Batteries, Alternators, & Starters• Max/Min of Current and Voltage• Microprocessor based control board protected from reverse connections• Testing of 12V and 24V electrical systems• Test all types of batteries • Ideal for testing remotely mounted batteries accurately• Automated 500A variable load tester• INCLUDES: Model 6043 1000 Amp AC/DC Inductive Amp Clamp for checking starter draw or parasitic drain test, also can be used with conventional multi-meters• Made in USA of US and Global Components

  • 12 Pulse SCR Controlled High Voltage Power Supply

    Carl E. Holmes Company

    - 12 Pulse SCR Controlled Power Supply, P/N 19435PS- Input: 480 VAC, 300 Amps, 3 PH, 60 Hz- Output: 0 to 3000 VDC ± 10%, 80 Amps max adjustable with potentiometers, and 4/20 mA input signals from the PLC- Output voltage and current are provided as 4/20 mA signals to PLC- Contactor and overload relay are installed for protection- Power ON Light- Start / Stop capability- EPO capability- Manual voltage control and current limit- PLC interface- Output voltage and current are displayed on the voltmeter and ammeter.- A selector switch is used to select between manual Control or PLC Control- The customer is responsible for the PLC controller and PLC programming- Power enclosure, 68″H x 65″W x 44″D- Control enclosure: 20″H x 16″W x 9″D- Weight: 5000 lbs. approximately- All input/output connections are inside the enclosure

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.