Showing results: 331 - 345 of 768 items found.
-
APCI-3120-16-8 -
TEAM SOLUTIONS, INC.
*Optical isolation 500 V*16 SE or 8 diff. inputs*Data transfer rate: 100 kHz*16-bit resolution*8 analog output channels*Data transfer rate:30 kHz*14-bit resolution
-
Thermotron Industries
The AVI (Analog Voltage Input) instrument has the functionality to operate as a multi-channel high-speed voltage monitor/logger. It is an intelligent instrument which uses its own onboard processor to monitor voltages and compare them to high and low limits.
-
78396-01 -
NI
4 AI (16-Bit, 800 kS/s/ch), 8 DIO, PXI Multifunction I/O Module - The PXI‑6120 is a simultaneous-sampling, multifunction data acquisition device. It offers analog input, digital I/O, two 24‑bit counters, and digital triggering. It is ideal for a variety of applications, such as stimulus/response applications for whih synchronization among analog input, analog output, and digital I/O is required; 42 V automotive applications; radar; sonar; and ultrasound. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
DAT4540R -
Datexel
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
104-AIO12-8 -
Acces I/O Products, Inc.
*Eight true differential inputs, or eight single-ended inputs optional*Programmable input ranges of: 0-5V, 0-10V, ±5V, ±10V*100KHz sampling rate*On-board pacer clock and counter timers*Four double-buffered analog outputs*Jumper selectable output ranges of: 0-5V, 0-10V, ±5V, ±10V*24 digital I/O lines, type 82C55 with change of state detect on port C, buffers on ports A & B*Flexible configurations to suit your needs
-
MX 256 -
Teledyne Gas & Flame Detection
The MX 256 is a digital control unit intended for the detection and measurement of gases present in the atmosphere and more generally for the processing of any digital signal from digital sensors (OLCT 10N types), relay module, analog output module, logic input module. Thanks to its new option, an industrial controller module or remote HMI, it is possible to add analog input modules for sensor-transmitter connection (4-20 mA) and / or relay modules, this allows to not only extend the capacities but also to have event recordings (Location, Alarms,.....) and to have access to the data via the embedded web page.
-
RogaDAQ16 -
ROGA-Instruments
With the introduction of the RogaDAQ16 USB 2.0 data acquisition system, a new age of measurement technology begins.*USB 2.0 / 480MBIT (USB1.1/12MBIT COMPATIBLE)*16 analog input channels (16bit/500kHz max.)*ICP ® ( IEPE ) sensor supply (24V/4mA)*0.125V to 10V input range*Individual preamplifiers*4 analog output channels (16bit/100kHz)*Powerful DSP (255MIPS) for filtering, control etc.*24 digital I/Os*Optional 24bit counter, timer, PWM, incremental encoder*Free drivers for major application software*including DASYLab; LabView & DiaDem drivers & RogaRec Software
-
DP-OBC-1122 -
Data Patterns Pvt. Ltd.
DP-OBC-1122 is a standard 3U cPCI Multi-Functional IO module. This board operates on 32bit, 33MHz PCI bus. The key function of the module is to provide analog IO interface, in addition to the various communication interfaces such as ARINC429, RS422 and Rs232.It has an ADC, operating with ±10V analog input catering for 8 single ended / 4 differential ended channels and a DAC which provides 4 channels of analog signals with a maximum output voltage of ±10V .The module also features standard communication channels and general purpose IOs.
-
GE-1400 -
Ono Sokki
Handheld type digital engine tachometer to be designed for dedicated r/min measurement of 4-cycle diesel engines. R/min direct reading measurement is available only by clamping a CP-044 Diesel Engine Rotation Sensor (sold separately) to a fuel injection pipe.Both analog (switchable between analog and monitor output) and pulse outputs are provided; enabling to use analog output for data recording (monitor output for sensor waveform checking or analysis input signal of FFT analyzer), and to use pulse output for tracking analysis signal of FFT analyzer.
-
ifm efector, inc.
*Inputs for analog, digital, diagnostic and pulse signals*Digital, PWM or current-controlled outputs*Programmable to IEC 61131-3 with CODESYS*High-performance CAN interface for various communication tasks*E1 type approval (German Federal Motor Transport Authority)
-
DP-100 -
PINTEK Electronics
*This is the first detachable design (patent for 15 years)*High frequency, big power using. Max. Measuring is 7000Vp-p.I*t is capable for any brand of digital and analog oscilloscopes.*Additional AC Adaptor.*16MΩ high input impedance.
-
PAV DIA01 -
Ponovo Power Co., Ltd.
PAV DIA01 is the optional accessory unit and Aurora digital interface for PONOVO’s power amplifiers which could convert the analog input signal into digital signal, supporting communication between power amplifier and simulators via AURORA protocol.
-
CR300-Series -
Campbell Scientific, Inc.
CR300 dataloggers are small, low-cost, high-value dataloggers with many of the features of other Campbell Scientific dataloggers. In addition, the CR300 dataloggers offer faster communications, low power requirements, built-in USB, and excellent analog input accuracy and resolution.
-
ADQ7WB -
Teledyne SP Devices
ADQ7WB is an RF digitizer with an analog input bandwidth of 6.5 GHz. It supports highly linear wideband data capture, and utilize Teledyne SP Devices' proprietary ADX technology in order to ensure industry-leading spurious-free dynamic range (SFDR).
-
780284-01 -
NI