Filter Results By:

Products

Applications

Manufacturers

Analysis

examine and interpret that sensed.

See Also: Analyze, Analyzers, Analytics, Data


Showing results: 766 - 780 of 3756 items found.

  • Application Specific LC Systems

    Nexera Amino Acid Analysis System - Shimadzu Corp.

    Amino acid analysis occupies an important role in diverse fields such as food science and pharmaceutical manufacturing. Nexera Amino Acid Analysis System uses detection by post-column fluorescence derivatization, with o-phthalaldehyde (OPA)/N-acetylcysteine as the reaction reagents, to selectively and with high sensitivity quantitate the amino acids contained in samples with high levels of contaminants.

  • Application Specific LC Systems

    Co-Sense for BA (Bio-sample Analysis) - Shimadzu Corp.

    Automate sample pretreatment for higher productivity.Innovative, efficient analysis of bio-samples.

  • Software

    Interface Trap Density Analysis Option - Materials Development Corporation

    MDC offers interface trap density analysis using both the Conductance-Frequency and Quasi-statictechniques. The Conductance-Frequency method is recommended for fine-tuning of processes where the highest resolution is needed. The Quasi-static technique is recommended where moderate to high levels of interface traps are monitored, such as in radiation damage studies. Requires quasi-static option or variable frequency option.

  • EDX-FTIR Contaminant Finder/Material Inspector

    EDXIR-Analysis Contaminant Finder/Material Inspector - Shimadzu Corp.

    EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues identification results and the degree of matching. it can also be used to perform EDX or FTIR data analysis on its own. The library used for data analysis (containing 485 data as standard) is original to Shimadzu, and was created through cooperation with water supply agencies and food manufacturers. Additional data can be registered to the library, as can image files and document files in PDF format.  It is also effective for the linked storage of various types of data as electronic files.

  • Application Specific LC Systems

    Nexera Organic Acid Analysis System - Shimadzu Corp.

    The Nexera Organic Acid Analysis System has been well-received in the fields of food and environment as a highly selective high-sensitivity system. It uses separation by ion exclusion chromatography and Shimadzu’s unique detection technique (pH-buffered electric conductivity detection). Recently, this system is being utilized by even more users in a wide variety of fields, and its usage in the fields of pharmaceuticals and life science is increasing.

  • Energy Dispersive X-ray Fluorescence Spectrometer

    Pharmaceutical Elemental Impurities Analysis System - Shimadzu Corp.

    Control of Elemental Impurities in Pharmaceuticals In the pharmaceutical industry, the analysis of elemental impurities is necessary to ensure the safety of pharmaceuticals. In December 2014, the "Guideline for Elemental Impurities" (Q3D) was issued by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH), consisting of representatives from Europe, the U.S. and Japan. In Japan, the "Guideline for Elemental Impurities in Drug Products" (PFSB/ELD Notification 0930 #4 from the Ministry of Health, Labour and Welfare) was issued, and will be applied to new drug products submitted for approval after April 1 2017. For 24 elements categorized in Class 1 to Class 3, residual quantities in pharmaceutical drug products must be controlled within permissible limits. Although ICP-AES and ICP-MS are used for precise analysis of elemental impurities, X-ray fluorescence spectrometers can be used as an alternative analysis method. This is because they can quantitatively and qualitatively analyze a variety of elements nondestructively, and without chemical pretreatment, unlike ICP-AES and ICP-MS systems. The X-ray fluorescence spectrometry has been adopted as a general method of analysis in the U.S Pharmacopeia and the European Pharmacopoeia. (USP<735>, Ph.Eur.2.2.37)

  • Software

    Interface Analysis - Akrometrix, llc

    Surface-mount components warp during the reflow process, and the area where they attach also changes shape during assembly. This interface between components is where solder, paste, and gaps created due to thermal expansion combine to create 100% good products, or defects such as Head-in-Pillow, Shorts, and Opens. Fully understanding that critical interface between surfaces is more important than ever.

  • Real Time Monitor Interface

    ANALYSIS 4N - ZOGLAB Microsystem Co., Ltd.

    It supports a management on the on-site equipment, such as to add subnets, to add subnet equipment, or to config equipment parameters, etc. Subnet fulfills the following applications: parallel communication, interaction with equipment, batch logging, downloading, configuration, ending, timing synchronization and system status viewing.

  • Winding Component EST Tester

    TH9520 - Changzhou Tonghui Electronic Co., Ltd.

    ■ Six-in-one comprehensive analysis: High-power AC withstand voltage analysis DC voltage analysis Insulation resistance analysis Turn-to-turn insulation analysis DC low resistance analysis Inductance test analysis ■ High-resolution: 7-inch 800 × 480 dots, TFT-LCD display

  • Winding Component EST Tester

    TH9520A - Changzhou Tonghui Electronic Co., Ltd.

    ■ Six-in-one comprehensive analysis: High-power AC withstand voltage analysis DC voltage analysis Insulation resistance analysis Turn-to-turn insulation analysis DC low resistance analysis Inductance test analysis (option) ■ High-resolution: 7-inch 800 × 480 dots, TFT-LCD display

  • Software

    Junction Measurement and Analysis - Materials Development Corporation

    A comprehensive set of analyses for junction diode or Schottky barriers begins with C-V data gathering that adjusts the voltage step to the slope of the C-V characteristics. This assures an optimum set of C-Vdata whether the voltage range is small or large. Doping profile and resistivity profile are both available at the touch of a key. Plots of 1/C2 - V or Log(C) - Log (V+ phi) show doping uniformity and doping slope factor. Exclusive recalculation options allow adjustment of stray capacitance and area to facilitate calibration using a standard reference wafer of known doping or resistivity.

  • Hardware Versatility

    Live Fatigue Analysis - Vibration Research Corporation

    With Fatigue Damage Spectrum, calculate the amount of fatigue your product will experience in a lifetime. Then, monitor your test as it is running to determine how long it will take for the product to arrive at the lifetime of accumulated fatigue. The hardware provides the length of time to reach fatigue in each axis.

  • Thermal Testing

    Pacific Testing Laboratories

    A view of multiple testing stations for use in conducting Thermal Analysis on various materials. This is one of several areas assigned to various thermal tests. Differential Scanning Calorimetry (DSC), Thermogravimetric Analysis (TGA), Thermomechanical Analysis (TMA), and Dynamic Mechanical Analysis (DMA)

  • Noise and Vibration Tester

    SKF Condition Monitoring Center

    High tech analysis and measurement such as frequency analysis (FFT) and further advanced analysis pinpoints faults. Spectral masks help to optimize the bearing performance in the particular customer application.

  • Testing Services

    Polymer Solutions

    Plastics testing, polymer analysis and metal testing solutions - if you have a problem and need physical analysis, material testing services, or chemical analysis, we want to solve it.

Get Help