Filter Results By:

Products

Applications

Manufacturers

Analyzers

examine data methodically by separating into parts and studying their interrelations. AKA: Analysers

See Also: Analyze, Analytics, Analysis


Showing results: 1666 - 1680 of 3973 items found.

  • Circuit Breaker Analyzers & Timers

    CAT Handheld Series - IBEKO Power AB

    When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.

  • PC-Based Time Interval Analyzer

    GT658PCI - Guide Technology, Inc.

    GuideTech’s GT658PCI is an ultra-fast, high resolution, DC – 400 MHz Time Interval Analyzer (TIA), ideal for most PC-based lab bench (timing) test applications. What makes the GT 658 superior to traditional counters is analogous to the difference between volt meters & digital scopes. While both measure voltage, the scope provides much more information about the dynamics of the signal. This is because our patented TIA substantially increases measurement speed, and the measurements are displayed as afunction of time. All of these features, along with the benefit of ‘continuous time correlation to a common reference between all measurement time stamps,’ enable our TIAs to make measurements that weren’t previously possible with traditional counters.

  • PXIe Network Analyzer Direct Access Receiver

    M9377A - Keysight Technologies

    The M9377A is one port PXIe Vector Network Analyzer direct access receiver which is used in the M9485A PXIe Multiport Vector Network Analyzer

  • CAPS Trace-Level NO2 Analyzer

    Model T500U - Teledyne Advanced Pollution Instrumentation

    The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.

  • Single & Two-Channel Power Analyzers

    280x Series - Xitron Technologies Inc.

    With an extended measurement range from micro-amps to hundreds of amps and millivolts to kilovolts, the 2801 & 2802 are the ideal analyzers for standby power or Energy Star testing. In addition to numerical results, the 2801 & 2802 captures waveforms with true 512-point precision. Results and waveforms can be displayed, read via communication ports or sent directly at full resolution to a USB printer. Power and amplitude measurements with an accuracy of <0.1% are automatically synchronized to the fundamental frequency. Peak, RMS, rectified and DC measurements of voltage, current and power are provided including continuous, inrush, startup and history modes, plus an integration mode for W-Hr, A-Hr, VA-Hr as well as integrated average power. (Channels can be operated synchronously or independently on the 2802). The 2801 and 2802 also provide waveform peak and glitch capture modes.

  • Real-time Web Log Analyzer

    GoAccess - GoAccess

    GoAccess is an open source real-time web log analyzer and interactive viewer that runs in a terminal in *nix systems or through your browser. It provides fast and valuable HTTP statistics for system administrators that require a visual server report on the fly. The main idea behind GoAccess is being able to quickly analyze and view web server statistics in real time without needing to generate an HTML report (great if you want to do a quick analysis of your access log via SSH). Although it is possible to generate an HTML, JSON, CSV report, by default it outputs to a terminal. You can see it more of a monitor command tool than anything else. Or if you are simply concerned about third party analytics tools using JS trackers.

  • PXIe Vector Network Analyzer RF Distributor

    M9340A - Keysight Technologies

    The M9340A PXIe vector network analyzer RF distributor is used in the M9485A PXIe multiport vector network analyzer. The module distributes the source and local signals from the source modules to the receivers.

  • Total Sulfur Process Analyzer

    NEX XT - Applied Rigaku Technologies, Inc

    Featuring third-generation X-ray transmission technology, the NEX XT represents the next evolution of process gauge for sulfur measurement (0.02% to 6% S) of crude, bunker fuel, fuel oils, and other highly viscous hydrocarbons, including residuums.The Rigaku NEX XT system is faster, more sensitive and far more compact than competitive systems, and provides continuous, reliable detection of sulfur at pressures up to 1480 psig. Rigaku NEX XT can operate as a stand-alone analyzer or provide real-time closed-loop control when tied into a blending or plant-wide automation system. Among its other key features are a simplified user interface, reduced standards requirement, automatic density compensation, password protection, and standard platform for communicating sulfur and density to a plant-wide DCS. Due to its unique design and robust construction, sample conditioning and recovery systems are typically not required.

  • Circuit Breaker Analyzers & Timers

    CAT Standard Series - IBEKO Power AB

    Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.

  • DDR Detective Logic Analyzer

    DDR4 - FuturePlus Systems

    Provides logic analyzer like deep transaction Listing and Waveform captureCan store up to 1G of captured StatesContinuous, real time analysis, not post-processingEye Detector guarantees valid data acquisitionExtensive Triggering and Storage Qualification allows precise insightProtocol Violation Detector provides hundreds of simultaneous, real time tests to JEDEC specificationsMargin analysis shows where command timing fails and where it can be improvedThousands of counters for DDR4 analyze performance metrics real time, all the time, for all commands, total Clocks, by Rank also power management informationInteractions among up to 8 ranks, over two slots are analyzed.Mode register and SPD capture are providedSupports Auto-Clock rate detect and clock stoppageConnects to the target under test with DIMM, SO-DIMM, and BGA interposers or a midbus probeIntegrated Microsoft Charts gives quick insight into large trace capturesTrigger In & Out allows the Detective to integrate with other test tools

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • Chemiluminesce​nce NOX-NO2-NO Analyzer

    Model N200 - Teledyne Advanced Pollution Instrumentation

    The Model N200 uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases.

  • CO2 Laser Spectrum Analyzer

    Macken Instruments, Inc

    The spectrum analysis screen has a response time of 1/4 seconds and permits the instrument to resolve all the CO2 rotational lines. The Model 16-A is light, portable and can easily be introduced into laboratory setups.

  • Code Execution Time Analyzer

    TimingProfiler - AbsInt Angewandte Informatik GmbH

    Constantly monitor timing behavior during software development, even at the earliest stages. Identify bottlenecks when you haven't even settled for a particular processor derivate yet, and measurements on physical hardware are plain impossible. This makes TimingProfiler ideally suited for constantly monitoring timing behavior during software development and in model-based development environments

  • Compressed Air Moisture Analyzer

    DewPatrol - PhyMetrix

    -110C to +20C dewpoint Sensor Fast, Accurate and Repeatable Built-in temperature compensation State-of-the-art electronics & software Advanced User-friendly Interface Small & Lightweight Graphical display Programmable data logging

Get Help