Showing results: 1801 - 1815 of 3911 items found.
-
MEXA-730λ -
HORIBA, Ltd.
Previously MEXA-700λII used know-how and ingenuity gathered from HORIBA air-to-fuel ratio measurement technologies used worldwide, to provide the highest level of performance.The MEXA-730λ adopts this performance and adds original design for enhanced visibility and operation.A new sensor coefficient data memory function makes it possible to restore back-up data, providing faster start-up times and saving valuable operation time.This enhanced device will meet your multiple testing requirements covering applications from, lab analysis of air-to-fuel ratio, excess air ratio and oxygen concentration, to on-board real time measurement.
-
KM 2100 / KM 2200 -
Kusam Electrical Industries Limited
• Volts / Amps. / Hertz, Dips & Swell, Power / Energy, Unbalance, Monitor, Scope, Harmonic, Logger & Interruption functions. (KM 2200)• Inter Harmonics, Transient Voltage, Inrush Current, Flicker function not available in KM 2200.• Frequency upto 400Hz (KM 2100); 50 / 60Hz (KM 2200)• Single-phase 2W / Single-phase 3W / 3-phase 3W / 3-phase 4W.• Flash memory 128MB• TF Card 8G Memory Card for long-term measuring data storage. • Support USB port to connect to PC and analyze the data / screen shots copied by U-disk.• Support LAN port to make the remote control available, transfer the measuring data.
-
CAEN S.p.A.
Dual independent 16k Digital MCA available in desktop and NIM from factors Dedicated to high resolution gamma ray spectroscopy.
-
780 MCA Family -
CAEN S.p.A.
The 780 MCA family integrates advanced firmware algorithms operating Digital Pulse Processing for Pulse Height Analysis (PHA). The processing algorithms can be easily adapted to different detectors and application ensuring effective data analysis even at high count rates. It provides advanced tools for configuring baseline restoration, pile-up rejection. Thanks to the two input simultaneous acquisition, the modules are able to manage coincidence and anti-coincidence logic between detectors, allowing the user, for example, to easily take advantage of background rejection or anti-Compton techniques. These MCAs may provide at the same time energy, time stamp and the digitized pulse in a configurable time window (e.g. including the rising edge region) in order to perform further online analysis. Acquisition settings and basic mathematical analysis are performed through the CoMPASS and MC2Analyzer software, providing energy spectra with up to 16k channels, which can be exported and imported in ASCII or N42.42 compliant files. CAEN further provides drivers for the supported communication interfaces; configuration software tools, C and LabVIEW libraries (CAENComm, CAENDigitzer, CAENDPP), demo applications and utilities.
-
DT5770 -
CAEN S.p.A.
The DT5770 is a compact portable 16k Digital MCA for Gamma Spectroscopy, integrating analog front-end with programmable gain and possible AC coupling. It is ideally suited for high energy resolution semiconductor detectors, like HPGe and Silicon, connected to a Charge Sensitive Preamplifier (CSP). The unit can also properly operate directly connected to a PMT with inorganic scintillators (e.g. Nal or Csl scintillators), provided exponential pulse shape and decay time above 200 ns.
-
Rapidox 2112 -
Cambridge Sensotec Ltd
The Rapidox 2112 Multiplex is housed in a 19″ rack mount unit and allows a programmed sequence of gas samples to be fed to a single gas analyser, thus saving money and space requirements.
-
LOG Storm -
Byte Paradigm
Logic analyzers are key tools for that process – they offer visibility over what happens in your digital electronic system.
-
DigiView™ DV509 -
TechTools
- Physical Channels: 9- Sample rate: 4ch@1 Gsps or 9ch@500Msps (4 ch. are sampled every 1ns or 9 ch. are sampled every 2ns)- Typical capture: 100M transitions (> 1B samples)- Hardware based triggers with 8 universal match circuits, and partitionable 16 stage sequencer- Adjustable Threshold (± 4V)- Real-time, Hardware-based, Adaptive Compression- Channels protected to ± 20V- Ground leads protected to ± 12V- High-quality test leads: 66 strand soft copper wires, flexible insulation, and gold plated connectors. Fit .025 square posts as well as the included clips.- Extra ESD protection- Streaming storage with auto fall-back to Store & Forward mode ensures large storage and reliability.- USB 3.0 (SS) or USB 2.0 (High Speed)- USB powered- Each DigiVIew includes all avialable Protocol Analyzer plugins (including: I2C, SPI, CAN, Async, Sync, 1-wire, I2S, TDM)- Free Plugin Developers' Kit- Requires Windows 7 or greater OS (32bit or 64bit)- Free Lifetime sofware updates.- 1 year warranty
-
DigiView™ DV518 -
TechTools
- Physical Channels: 18- Sample rate: 4ch@1 Gsps or 9ch@500Msps or 18ch@1Gsps (4 ch. are sampled every 1ns or 9 ch. are sampled every 2ns or 18 ch. are sammpled every 4ns)- Typical capture: 100M transitions (> 1B samples)- Hardware based triggers with 8 universal match circuits, and partitionable 16 stage sequencer- Adjustable Threshold (± 4V)- Real-time, Hardware-based, Adaptive Compression- Channels protected to ± 20V- Ground leads protected to ± 12V- High-quality test leads: 66 strand soft copper wires, flexible insulation, and gold plated connectors. Fit .025 square posts as well as the included clips.- Extra ESD protection- Streaming storage with auto fall-back to Store & Forward mode ensures large storage and reliability.- USB 3.0 (SS) or USB 2.0 (High Speed)- USB powered- Each DigiVIew includes all avialable Protocol Analyzer plugins (including: I2C, SPI, CAN, Async, Sync, 1-wire, I2S, TDM)- Free Plugin Developers' Kit- Requires Windows 7 or greater OS (32bit or 64bit)- Free Lifetime sofware updates.- 1 year warranty
-
780935-01 -
NI
The PCIe‑GPIB+ combines an IEEE 488 controller and an analyzer on one device for computers with PCIe slots. You can use this device to integrate an instrument into your system using GPIB as well as to troubleshoot and solve GPIB hardware and software problems. The PCIe‑GPIB+ achieves maximum IEEE 488.2 transfer rates. With an onboard bus master DMA controller, there is no microprocessor interruption in data transfers. The device includes a license for the NI‑488.2 driver software, providing maximum reliability for connecting to third-party instruments with GPIB.
-
787251-01 -
NI
PXIe, 9 GHz PXI Vector Network Analyzer - The PXIe-S5090 is a 2-port Vector Network Analyzer (VNA) that helps you measure amplitude, phase, and impedance. You also can use the PXIe-S5090 to perform time-domain analysis and to calculate the S-parameters of 2-port RF devices. It features a 300 kHz to 9 GHz frequency range, a wide dynamic range, and high sweep speeds for automated design validation and production test. Additionally, the PXIe-S5090 supports automatic precision calibration, full vector analysis, and reference plane extensions.
-
Virtins Technology
Audio Analyzers, Acoustic Analyzers, and Electro-Acoustic Test Accessories
-
SR785 -
Stanford Research Systems, Inc.
The SR785 Two-Channel Dynamic Signal Analyzer is a precision, full-featured signal analyzer that offers state-of-the-art performance at a price that's less than half that of competitive analyzers
-
N9936B -
Keysight Technologies
A lightweight, durable, microwave spectrum analyzer, interference analyzer, distance-tracking generator, preamplifier, power meter, and more
-
COA-3030 -
Shimadzu Corp.