Filter Results By:

Products

Applications

Manufacturers

Analyzers

examine data methodically by separating into parts and studying their interrelations.

See Also: Analyze, Analytics, Analysis


Showing results 2671 - 2685 of 3059 products found.

  • Waveguide Harmonic Mixers (smart mixer), 60 to 90 GHz

    M1970E - Keysight Technologies

    The Keysight M1970E 60 to 90 GHz waveguide harmonic mixer is an un-preselected mixer that will extend the operating frequency range of the N9030A PXA, N9020A MXA,and N9010A EXA signal analyzers up to 90 GHz. Smart features are embedded to help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.

  • Waveguide Harmonic Mixers (smart mixer), 75 to 110 GHz

    M1970W - Keysight Technologies

    The Keysight M1970W 75 to 110 GHz waveguide harmonic mixer is an un-preselected mixer that will extend the operating frequency range of N9030A PXA, N9020A MXA,and N9010A EXAsignal analyzers up to 110 GHz. Smart features are embedded to help you to greatly simplify your overall test setup and improve your DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.

  • Waveguide Harmonic Mixers (Smart Mixers), 55/60 to 90 GHz

    M1971E - Keysight Technologies

    Keysight M1971E 55/60 to 90 GHz waveguide harmonic mixers is an un-preselected mixer provides a complete solution for wideband millimeter-wave signal analysis of more than 2 GHz with X-Series signal analyzers. Smart features are embedded to help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.

  • AC Power Sources

    Compact iX Series - California Instruments

    The Compact iX Series represents a new generation AC and DC power source that addresses increasing demands on test equipment to perform additional functions at a lower cost. By combining a flexible AC/DC power source with a high performance power analyzer, the Compact iX Series is capable of handling complex applications that have traditionally required multiple systems.

  • Current Sources

    CS Series - California Instruments

    The CS Series represents an advanced AC current source that addresses increasing demands on manufacturers to test products using real-world current profiles. By combining true current transconductance amplifiers with an advanced digital controller and harmonic power analyzer, CS Series current sources are capable of performing tests that would traditionally have been difficult to accomplish.

  • Test Automation Platform Deployment System

    KS8000A - Keysight Technologies

    TAP is a modern Microsoft .NET-based application that can be used stand-alone or in combination with higher level test executive software environments. The Keysight KS8000A Test Automation Platform (TAP) Deployment System provides a lower cost, scaled down alternative to the full KS8400A TAP Developers System without the graphical user interface, results viewer and timing analyzer. Deploy your existing test software and TAP plugins into manufacturing environments using the KS8000A command line interface or your own interfaces.

  • XYZ Color Sensor

    AS7261 - ams AG

    Calibrated XYZ color sensor provides complete, integrated platform for handheld color analyzers, color calibration and mobile analysis devices. Tri-stimulus XYZ realized by silicon interference filters. UART or I²C slave digital Interface. 16-bit ADC with digital access. Programmable LED drivers. 20-pin LGA package 4.5mm x 4.7mm x 2.5mm, with built-in aperture. Compact true-color sensing. Applications; Color/CCT sensing, Fluid or reagent analysis, Color point comparison, Display calibration.

  • Harmonic Mixers

    HXI, llc

    The HHM series of broadband harmonic mixers covers full waveguide bands from 26.5to 110 GHz. The mixers utilize a low loss finline structure mated to a GaAs Schottky beam lead diode for minimum conversion loss and maximum bandwidth. The millimeter wave RF frequency is down converted (using a lower microwave LO frequency) to an intermediate frequency (IF) which can in turn interface with a spectrum analyzer, frequency counter, etc.

  • Tone Generator

    ComTekk Engineering, LLC.

    Control and test 2-way radio systems, repeaters, ANI, Paging and more. Activate 2-tone or 5/6-tone pagers. Operate or test EIA tone-remote systems. Record generated signals to a WAV file Accomplish MORE, by carrying LESS hardware in the field. Monitor inputs and outputs with our FREE built-in audio scope and spectrum analyzer. No external hardware required. Output may be fed directly into radio, twisted pair, or service monitor.*

  • Power Splitter, DC to 26.5 GHz

    11667B - Keysight Technologies

    The Keysight 11667B power splitter is recommended when making wideband ratio measurements using a Keysight 8757 scalar network analyzer. This two-resistor type power splitter provides excellent output SWR at the auxilliary arm when used for source leveling or ratio measurement applications. The tracking between output arms over a frequency range from dc to 26.5 GHz allows wideband measurements to be made with a minimum of uncertainty.

  • Power Splitter, DC to 50 GHz

    11667C - Keysight Technologies

    The Keysight 11667C power splitter is recommended when making wideband ratio measurements using a Keysight 8757 scalar network analyzer. This two-resistor type power splitter provides excellent output SWR at the auxiliary arm when used for source leveling or ratio measurement applications. The tracking between output arms over a frequency range from dc to 50 GHz allows wideband measurements to be made with a minimum of uncertainty.

  • Extrel RGA

    Extrel CMS, LLC

    The Extrel RGA is a reliable, easy-to-use residual gas analyzer that includes full range pressure measurement. It is the best performing RGA at an affordable price, which makes the system an ideal choice for background gas analysis, leak detection and vacuum chamber characterization. The Extrel RGA is available in two (2) mass ranges, 1 to 100 amu or 1 to 300 amu. The system comes standard with a Faraday detector or an optional dual Faraday/Electronic multiplier detector.

  • Driver Fatigue Analysis Alarm Device

    FIRS Technologies(Shenzhen) Co.,Ltd.

    The driver fatigue analysis alarm device, designed based on the intelligent video analysis technology, is composed of the intelligent video surveillance camera and analyzer. Camera is used for captures of the facial image, and accurate locating of the driver's eyes. This product can make automatic estimation and analysis of the state of the eyes to judge the fatigue degree according to pre-set rules. If eyes' closing time reaches the alarming value, the product then will automatically alarm to warn the driver. Meanwhile, the alarm information will be sent to the back-end monitoring center.

  • Solar Test Systems

    Princeton Applied Research

    Ametek Scientific Instruments manufactures a range of application specific XM (Xtreme Measurement) products focused on solar cell / photovoltaic research (developed in collaboration with Professor Laurie Peter of the University of Bath, UK). These products are so versatile that they can also be used for photoelectrochemical (PEC) water splitting applications; and make use of Solartron’s unique high performance XM specified potentiostats and frequency response analyzers to provide a full complement of techniques for research into energy, corrosion and analytical electrochemistry.

  • Maintenance & Service

    Teledyne Advanced Pollution Instrumentation

    Get peace of mind with preventative maintenance procedures that when performed regularly, will help to ensure your analyzer continues to operate accurately and reliably over its lifetime.Proactive maintenance at scheduled intervals is key to your equipment’s accuracy and longevity. Pre-planned, periodic maintenance provides cost control with complete trust that your equipment is achieving:Consistent, accurate resultsExtended instrument lifeEliminate premature replacement of equipment.The best performance possibleEquipment downtime is decreased and the number of major repairs are reduce