Showing results: 691 - 705 of 957 items found.
-
40-190B-501 -
Pickering Interfaces Ltd.
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-201 -
Pickering Interfaces Ltd.
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-202 -
Pickering Interfaces Ltd.
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-101 -
Pickering Interfaces Ltd.
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-401 -
Pickering Interfaces Ltd.
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-001 -
Pickering Interfaces Ltd.
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-102 -
Pickering Interfaces Ltd.
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
40-190B-301 -
Pickering Interfaces Ltd.
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
QT-8000 Series -
PowerTECH Co,Ltd.
Tester is applicable to regularDC/AC parameter testing and IC device performance testing. Main application: Power Management; Digital Consumer Products; Communication& Interface; Automotive; Energy Conservation electronics; Standard Linear Circuit; Memory; CPU Chips; Special Customized IC and Wafer Test.
-
41-740-001 -
Pickering Interfaces Ltd.
This PXI dual programmable power supply module is designed specifically for test applications that demand precision output voltage/current and tightly coupled measurement capabilities. Its versatile design makes it ideal for a broad range of testing applications in markets as diverse as communications, aerospace, and automotive manufacturing.
-
LXinstruments GmbH
The application encompasses functional tests of very large quantities of automotive antenna amplifiers, plus parallelization of tests by implementing several test stations in a rotary indexing table. The DUTs are inserted manually and after final assembly, they are loaded into the rotary table; this requires manual triggering by the operator.
-
Premier Electrosystems
Premier Electrosystems offers more than 100 power supply products, which are suitable for the requirements of Electronic Assembly Testing, Education, Component Testing, Wireless Product Testing, Electric Vehicle Charging, Burn-in, Battery-Power Product Testing, Automotive and Aerospace industries and so on. Most models include a wider operating range with constant power, higher current ranges, precision readback of output current and voltage, output trigger signals, as well as the ability to create complex DC transients waveforms to test device behavior with voltage deviations. Our programmable DC power supplies are commonly used in DC-DC converter, PV inverter, telecom, battery charger, EV / automotive, burn-in, and plating/electrolysis testing.
-
LT-01 -
Jinan Leading Instruments Co., Ltd.
LT-01 Leak Tester is applicable in leak testing of pouches, bottles, pipes, cans and boxes of foodstuff, pharmaceutical, medical, daily chemistry, automotive, electronic components, stationary and other industries. It's also applicable in the leak testing of the specimens after falling tests and pressure resistance tests.
-
S.E.A. Datentechnik GmbH
The increasing use of electric drive systems both in the automotive industry and in transportation requires the development of new high-performance energy storage systems. In order to support you in the development and production of these systems, S.E.A. develops individually configurable test systems which are scalable and can be used flexibly for the respective requirements.
-
EH118 -
MVG EMC
EH118, a dual-ridge horn antenna that will operate from 1 to 18 GHz. This antenna has a balanced, smooth antenna factor curve that extends all the way to 18 GHz, a reduction of higher order modes on the aperture, and low return loss (SVSWR). The EH118 is applicable for commercial, military and automotive test standards and will include applicable calibrations. The EMC dual-ridge horn antenna offers these key features: single linear polarization, smooth/balanced gain with frequency, low return loss /VSWR, and ultrawide bandwidth (18:1).