Showing results: 331 - 345 of 2296 items found.
-
Hangzhou Xun Anda Electrical Co., Ltd.
1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery.3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish.9. Intergrated thermal printer to print test reports.10. Thermal printer paper roll is 58mm width and 7.5m long.
-
Hangzhou Xun Anda Electrical Co., Ltd.
1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery.3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish.9. Intergrated thermal printer to print test reports.10. Thermal printer paper roll is 58mm width and 7.5m long.
-
BT175 -
Schumacher Electric Corporation
DIGITAL TESTER FOR 12V BATTERIES/STARTER SYSTEMS/CHARGING SYSTEMSHand-held tester checks the battery, starting and charging systems with digital accuracyDigital display guides you through the testing process and shows voltage and CCALEDs indicate OK, OK & Recharge, Recharge & Retest, Weak, Bad Battery and Error For 12V SLI and VRLA/AGM/GEL batteriesAccepts rating types CCA, CA, EN, IEC, DIN and SAEOperating range: 100-1200 CCA (SAE)Testing voltage: 7-15VContents: (1) Schumacher BT175 Digital Battery Tester (1) owner's manual
-
-
41-750-001 -
Pickering Interfaces Ltd.
The 41-750 is a battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals than can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
Buckleys Ltd.
Battery boxes can be tested for faults by placing the box on a metal plate. By applying a test voltage to an electrode inside the box, the moulding can be checked thoroughly - particularly at the injection points - and any faults found. Defects will be identified by a spark passing from the electrode, through the defect itself, to earth (the conductive material placed outside the battery box.
-
BTAS-16 -
JFM Engineering
The task of testing an aircraft’s Nickel-Cadmium batteries is complicated and involved because of the high number of cell voltage readings that need to be taken during testing. Taking voltage readings from all 20 cells in the typical nickle-cadmium aviation battery multiple times is laborious and error prone, but must be done to properly estimate the condition of the battery under test.
-
C19 -
Fuzhou Fuguang Electronics Co., Ltd.
C19 series is a portable tester which can quickly inspect battery pack of two-wheel vehicles. It can realize quick inspection and selection of SOH data of battery pack and discharge-charge maintenance. Data can be transferred to the mobile phone APP through Bluetooth forming a statistics report and faulty cell warnings so that further maintenance solutions can be developed in time.
-
41-751-001 -
Pickering Interfaces Ltd.
The 41-751 is a low power battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals than can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
Megaron Ltd.
From the beginning of 2006 the verification of measurements of the analyzer of lead-acid chemical sources developed by Company "Megaron" is spent in Test laboratory "Neva-Reglament". The analyzer is intended for the express-estimation of a condition of lead-acid batteries: before the first use of new battery (an estimation of the electric characteristics declared by the manufacturer); during the battery operation (an estimation of a condition and working capacity at real application).
-
KV Hipot Power Test Equipment Co.,Ltd
Battery Regeneration is a portable and compact tester which is used on discharging, charging and activating for disabling individual cell batteries.
-
-
IBEKO Power AB
Performing capacity/discharge test on a high-capacity battery may be challenging since high requirements are set on the discharge system. In cases when discharge test times need to be reduced, high load capacities are required from the discharge system. The battery extra load unit BXL is an additional load unit designed especially for this purpose.It is primarily used with BLU battery testers. However, the unit is a universal add-on device. This means it can be used as an additional load with any other discharge/capacity tester in the market.When discharge current exceeds the capacity of a single BLU device, extra load unit increases discharge capacity. A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way in accordance to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.
-
FST-7000 -
Foresight Electronics Co., Ltd.
Battery Conductance Tester is a portable digital measurement device for testing lead acid stationary batteries health and aging condition precisely within seconds. With the help of this device either single cells / blocks or large, multi group battery banks can be measured within a short time and the precisely measured data are processed and reported by given analyzer software automatically.
-
PRODIGIT Electronics Co, Ltd.
*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery.