2720 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.
-
1820 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
4120 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.
-
Hilkar
Test Laboratory Reactors are designed for high voltage and high power test laboratories. They are designed to withstand the most extreme electrical service conditions during test periods. Design techniques are implemented in accordance with the most demanding service conditions. These reactors are used for various purposes in test laboratories such as current limiting and synthetic testing of circuit breakers, capacitor testing, artificial line simulation etc.
-
Hilkar
Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.
-
IPMDS100 -
Technology Research Corp.
- Intelligent Power Management System- 3 - 20 Amp Single Phase Outlets- 3 - 40 Amp Three Phase Outlets- 2 - 60 Amp Three Phase Outlets- Automatic Load Shedding- 100 Amp Mil Spec Input and Output Connector- Easy Access Circuit Breakers- Phase Over Current Protection- Low Voltage Warning- Built In Press to Test
-
Kharkovenergopribor Ltd.
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
8020 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Frequency : 820Hz.● 0Ω adjustment.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.● Simplified measurement probe is also provided for two-wire measuring method.
-
1105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
4105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
2105 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● In addition to facilitating for precision measurement, test leads for simplified two-wire measuring system also are supplied as standard accessories.● Battery operated.● Battery life indicator. ● Calibration performed with supplied test leads.
-
1805 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
2120 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● 0Ω adjustment.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
2705 ER -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
Hilkar
For low and medium voltage switchgear including :*Circuit breakers*Contactors*Disconnect switches*Fuses*Miniature circuit breakersApplied tests for low and medium voltage switchgear :*Dielectric withstand test*Impulse withstand test*Breaking capacity test*Mechanical life testElectrical life test*Over load performance test*Short circuit breaking capacity test**Short time short circuit impulse current test*Temperature rise test*Operation performance testTests for low & medium voltage panels :*Short time short circuit impulse current test*Dielectric test*Impulse withstand voltage test*Temperature rise test