Showing results: 181 - 195 of 425 items found.
-
Shirla -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR shirla. Shirla the fault location system is used for cable and cable sheath testing as well as for pre-location and pinpointing of cable faults. The pre-location based on the measuring bridge principle according to Murray and Glaser that is designed especially for power cables, also enables pre-location for control and lighting cables. Null balance and evaluation take place automatically.* Cable and cable sheath testing up to 10 kVC* Resistance measurement* Cable and cable sheath fault pre-location with precision measuring bridge* Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation
-
MultiDimension Technology Co.,Ltd.
Magnetic grate sensors integrate two push-pull Wheatstone bridges, each of which contains four high-sensitivity anisotropic magnetoresistance (AMR) sensing elements. Such a design effectively compensates temperature drift to ensure high accuracy under wide temperature range.
-
ZET 7110 -
ZETLAB Company
The ZET 7110 module is intended for measuring the relative deformation using primary transducers based on tension gauges. These may be either assembled tension gauges (force gauges, torque gauges), or detachable tension gauges connected using half-bridge or bridge mode.
-
106 -
Elcometer Limited
Applications for the Elcometer 106 Adhesion Test include paint or plasma spray on bridge decking, coatings on steel, aluminium, concrete etc.Supplied in a carry case - ideal for site testsHand operated - no need for a power supplyIncludes a cutter for EN13144 and ISO 4624 tests
-
cBP-3213PR -
ADLINK Technology Inc.
*PICMG 2.0 CompactPCI Specification Rev. 3.0 *compliantOne system slot and twelve peripheral slots via cBP-*R3213 bridge boar10-layer PCB for accurate impedance control and electronic noise immunity*Two ATX sockets with DC screw terminals
-
Eurotech Inc
*CompactPCI (cPCI) boards are 3U or 6U boards connected via a passive PCI (Peripheral Component Interconnect). Up to 8 boards can be connected together in a segment. Segments can be connected through bridges. *They are grouped into four categories: CPU, Communication, Input/Output, PMC carrier.
-
ECAT STGMM 6 -
CSM Products, Inc.
Precise and synchronous acquisition of mechanical strain directly at the strain gauge points of application: This is what the EtherCAT®-based measurement module ECAT STGMM 6 with six time-synchronous strain gauge inputs for quarter-, half- and full bridges has been designed for
-
Guildline Instruments Ltd
DC Resistance and Current Measurement System including: 6622A Series Bridge, 6634A Temperature Stabilized Resistance Standards, 6664C Scanner(s), world’s most precise and stable 6623A Precision Current Source/Range Extender, Wired Equipment Rack, and Bridgeworks Software.
-
Guildline Instruments Ltd
QUANTUM HALL SYSTEM has been developed to meet the needs of Standards Laboratories around the world for an improved level of accuracy in the calibration and maintenance of primary resistance standards. Includes QHR Sample(s), Magnet, Cryogenics and Room Temperature 6622A-QHR Resistance Bridge.
-
HeavyDuty encoders -
Baumer Holdings AG
For decades Baumer HeavyDuty encoders have offered unmatched reliability under the toughest application conditions. Whether in container crane systems, lifting bridges, steel mills or wind turbines - the HeavyDuty encoders are extremely robust, very durable, absolutely reliable and and fail-safe.
-
ZET 7111 -
ZETLAB Company
The ZET 7111 module is intended for measuring the relative deformation using primary transducers based on tension gauges. These may be either assembled tension gauges (force gauges, torque gauges), or separate external tension gauges connected using half-bridge or bridge scheme.
-
PCIBPMC -
Dynamic Engineering
1/2 Length Bridge Based PCI Adapter Carrier Card with PMC Mounting Slot. The PCIBPMC ( PCI Bridge PMC ) adapter / carrier converter card provides the ability to install a PMC card into a standard PCI slot. The PCIBPMC has a PMC card slot mounted to a universal 1/2 length PCI card. Suitable for 32 bit or 64 bit bus operation. The PMC user IO connector Pn4 is brought out to one of two connectors for access (DIN IDC or SCSI II). The signals corresponding to the PrPMC standard Ethernet and Serial lines can optionally be connected to the Ehternet and Serial port connectors at the top edge of the board.
-
6332 -
Technobox, Inc.
Our Dual-Site Single-Slot 6U Compact PCI (cPCI) PMC Adapter/Carrier 32-Bit/66 MHz (6332) adapts two single-wide PMCs to a cPCI slot. At the heart of the carrier is a 6150 PCI-to-PCI bridge that connects the carrier's internal PCI bus to the cPCI backplane.
-
6567 -
Technobox, Inc.
Our Five-Site Dual-Slot 6U Compact PCI (cPCI) PMC Adapter/Carrier 32-Bit/66 MHz (6567) adapts five single-wide PMCs to a cPCI slot. At the heart of the carrier is a 6150 PCI-to-PCI bridge that connects the carrier's internal PCI bus to the cPCI backplane.
-
U2C-12 -
Dimax