Filter Results By:

Products

Applications

Manufacturers

Bridges

span gaps.

See Also: Noise Bridges


Showing results: 331 - 345 of 425 items found.

  • Motion Based Waves

    Aanderaa Data Instruments AS

    Accurate Motion Based wave measurements are critical in applications such as offshore wind farm development, navigation, cable laying, breakwater building, and bridge construction.Waves also result in continuous loads on marine structures, including docks, moorings, and offshore platforms.Motion Based Waves are challenging to measure. Variables to consider when collecting wave data include the depth of the measuring device, proximity to shore, wave types, and available infrastructure from which to measure.Several methods for measuring motion based waves are available, and careful selection of the best approach is needed to get the optimal result.

  • Fully Automatic Transformer Winding Resistance Tester

    Neutronics Manufacturing Co.

    Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.

  • CompactPCI Instruments

    Frequency Devices Inc.

    Is a computer bus interconnect for industrial computers,combining a Eurocard-type connector and PCI signaling and protocols. Boards are standardized to 3U or 6U sizes, and are typically interconnected via a passive backplane. The connector pin assignments are standardized by the PICMG US and PICMG Europe organizations. The connectors and the electrical rules allow for eight boards in a PCI segment. Multiple bus segments are allowed with bridges.

  • PXIe-8360, x1, MXI-Express Interface, PXI Remote Control Module

    779700-01 - NI

    PXIe, x1, MXI-Express Interface, PXI Remote Control Module—The PXIe‑8360 allows you to control PXI and CompactPCI systems from your PC using a fully transparent MXI‑Express link. It is installed in a PXI chassis and uses a PCI Express‑to‑PCI bridge to interface with an installed PCI‑8360 through a copper, x1 MXI‑Express cable.

  • PXIe-8381, x8, MXI-Express Interface, PXI Remote Control Module

    782362-01 - NI

    PXIe, x8, MXI-Express Interface, PXI Remote Control Module—The PXIe‑8381 allows you to control PXI and CompactPCI systems from your PC using a fully transparent MXI‑Express link. It is installed in a PXI chassis and uses a PCI Express‑to‑PCI bridge to interface with an installed PCIe‑8381 through a copper, x1 MXI‑Express cable.

  • Load Cell DIN Rail Signal Amplifier

    LCD20 - Mantracourt Electronics Ltd

    Our intelligent strain gauge bridge amplifier is a compact, stackable microprocessor based unit specifically designed to control and monitor process applications. Flexible connection to most load cells, pressure or strain gauges over a wide range of sensitivities. The unit provides isolated current 4-20mA and voltage 0-10V analogue outputs and two digital inputs. Two set point relays can be configured to set thresholds such as net, gross, peak and valley. Powered from a wide ranging DC supply, the DIN rail amplifier is supplied with 2 part screw connectors for ease of installation.

  • Micro - Ohmmeter / Milli - Ohmmeter

    Meco Instruments Pvt. Ltd.,

    Basic Accuracy 0.25%Max. Test Current : 5A (120mV) for 7002Max. Test Current : 10A (60mV) for 7272Manual or Auto RangeFour Terminal Kelvin Measurement6 Ranges with 1mV Best ResolutionMeasurement of Resistive and Inductive MaterialsSetting for HI, LO & PASS ReadingsMemory of 3000 Measurements DataProgrammable HI-LO Alarm with memory of 20 DataLarge LCD with Backlight & HOLD FunctionLow Power ConsumptionBattery Operated with AC AdaptorLow Battery (Voltage) AlarmLED indication for Invalid Resistance MeasurementCable Length Measurement in feet & metersUser Interface Software for PC Communication via RS232C(to USB Bridge) cableBuilt-inBatery Chaging Circuit & Calender Clock

  • Precision Thermometer

    F252 - ASL

    ASL's F252 provides high accuracy, dual channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F252 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F252's memory, so that thermometer resistance can be accurately converted to temperature in C, F or K. This can be password protected to prohibit unauthorised or accidental data entry.

  • IceMap™

    Real Time Ice Thickness Measurement - Sensors and Software Inc.

    The IceMap real-time display shows the automatically detected bottom of the ice (blue line) in real time. Users can set a minimum thickness warning threshold (gold line). Winter ice roads and bridges are a common transportation link in the northern regions of Canada, Alaska, Europe and Russia. The Sensors & Software IceMap system is designed to measure the ice thickness on these temporary, yet vital, links and ensure the safety of all travelers. The GPR sensor is towed across the ice surface behind a truck or snowmobile and the ice thickness data, displayed in real-time as a cross-sectional image, are sent wirelessly to the operator’s computer.

  • Load Monitoring Units (LMUs)

    Magtrol Inc.

    Magtrol's Load Monitoring Units are used for measuring load, force and weight from signals generated by strain gauge transducers. Specifically designed for use with Magtrol's Load Measuring Pins and Load-Force-Weight Sensors, the LMU Series provides excitation voltage while conditioning the bridge output signal. Each unit contains DIP-switches and jumpers for greater flexibility and complete adaptability

  • MirrorLink Test System

    Catena 2210 - MCCI

    The Catena 2210 is a test tool with two USB Network Control Model ("NCM") devices. These devices create a bridge between two USB hosts. Validation testing is made possible by connecting a test control computer to the USB host being tested. Ethernet traffic from the test host is transferred through the Catena 2210 device to the control host, and vice versa.

  • LVDT Sensor Amplifiers

    Analog Devices Inc.

    Analog Devices signal conditioning ICs, together with linear variable differential transformers (LVDTs), can be used to convert mechanical position to a dc voltage. The IC provides both the excitation for the LVDT and the output conversion to dc level with a user selectable gain. ADI LVDT signal conditioners are available to interface with a wide range of LVDTs, including half bridge and standard 4- and 5-wire.

  • Thermal Conductivity Gas Analyzer

    CI2000-RQD - Shanghai ChangAi Electronic Science & Technology Co.,Ltd

    Determining gas concentrations by measuring the thermal conductivity of the gas, CI2000-RQD analyzer uses advanced thermal conductivity sensor with single chip technology. It adopts platinum thread as sense organ to make up Imbalance Bridge, which output signal has a relationship with tested gas volume. And the single chip will magnify, sieve wavelength, modify linearly and criteria the signal by electric procedure.

  • CompactPCI Chassis

    Kontron

    CompactPCI is a standard in computer bus technology for industrial computing that utilizes a Eurocard type connector combined with PCI signaling and protocols. cPCI boards come in 3U and 6U variants and are typically interconnected through a passive backplane. The connector pin assignments are standardized by PICMG , allowing for eight boards in a PCI segment with multiple bus segments being allowed with the use of active bridges.

  • Free Serial-TCP (More Than Just A Device Server)

    CommFront Communications

    In the past two decades, legacy serial communication protocols such as Modbus have merged rapidly with modern TCP/IP communication, yielding benefits including widely available infrastructures and greater distance, reliability, and speed. The Serial-TCP program (more than just a Device Server) bridges your existing Serial COM port and TCP/IP without the need for changing existing protocol. It works seamlessly and transparently, just like passive RS232 / RS485 / RS422 converters, repeaters, and hubs, while the difference is that one requires installation of cables and converters with limited distance; and the other simply makes use of the existing computers and networks with an unlimited transmission distance

Get Help