Showing results: 196 - 210 of 5247 items found.
-
Shanghai Beha Electronics Co., Ltd.
*Cable length measurement by pulse reflection measurement, only required one cable end (with two wires)*Resistance measurement*Acoustic continuity test
-
CLM1 -
NG Systems Ltd
The Cable Length Meter CLM1 will allow the accurate measurement of severed or open/short-circuit CCTV coaxial cable. For use with RG59 (75Ω) and RG58 (50Ω) or equivalent coaxial cable, this meter provides a direct readout in metres of the length of an unterminated run of coaxial cable with a resolution of 2-3 metres. A single range of 2.5 to 400 metres on a 4 digit LCD display is provided with automatic indication of open circuit and short circuit conductors. By this means, the location of a short circuit or open circuit in cable runs of up to 800 metres may be found.
-
Hubbell Power Systems Inc
The purpose of the Energized Cable Sensor is to allow the lineman to readily determine whether a URD cable is energized. The sensor consists of an amplifier which is designed to give a meter reading when the small AC voltage between the semi-conductive sheath and the concentric neutral of the energized URD cable is applied to the test probe. The amplifier is housed in a rugged phenolic case. Sensor may be used to check for energized condition on concentric-neutral cable below an elbow without test points. At cable mid-span (left), hose clamps bridge all strands of concentric neutral at the test location. Sensor’s neutral lead clips to one of the hose clamps. Tip on probe lead contacts only semi-conductive cable sheath to test for voltage presence.
-
Fluke Networks
The MicroScannerTM Cable Verifier series simplifies the testing of voice, data, and video cable. It starts by taking results from what was four different test modes and displaying them all at once – graphical wiremap, pair lengths, distance to fault, cable ID, and far end device.
-
-
-
-
-
787168-01 -
NI
48DINM-48DINF Digital Cable
-
-
AMETEK Sensors, Test & Calibration
Cable Reels can be used as a linear position sensor in any industrial application to monitor a linear or reciprocating machine motion. The system consists of a heavy duty spring motor assembly attached to a precision machined cable drum. As the cable is pulled off of the drum, the drum rotates a rotary position sensor.
-
NCT-100-S -
ShinewayTech
*NCT-100-S Multi-Function Cable Tester Kit can help you quickly find network cables with OOK audio during network construction and maintenance. *Use TDR diagnostic technology to quickly and accurately locate fault points and accurately measure wiring diagrams and lines. Cable identification, etc.
-
Analog Devices Inc.
Analog Devices high speed, differential receivers and CAT-5 cable equalizers compensate for the transmission losses of UTP and coaxial cables up to 300 meters in length. Our design techniques for products such as the AD8123 optimize performance for low noise, short-to-medium range applications, while also providing the high gain bandwidth required for long cable equalizations. Various gain stages are summed together to best approximate the inverse frequency response of the cable. Logic circuitry controls the gain functions of the individual stages so that the lowest noise can be achieved at short-to-medium cable lengths.
-
T040-001-DP -
Tripp Lite
DisplayPort Cable Tester: An Essential Tool for A/V Cable InstallersAvoid the problems and costly troubleshooting caused by a bad DisplayPort cable. This DisplayPort tester allows you to quickly and accurately verify DisplayPort and Mini DisplayPort cables before installing them behind walls and in other tough-to-reach places. It’s recommended for installers of digital signage applications and home theater systems who need to verify straight or crossed connections and open or short circuits.
-
PCB Piezotronics, Inc.
Cables are a critical part of any sensor measurement system and damaged cables cause frequent delays during test setup. PCB has developed a relatively simple device to test cables on a channel by channel basis for BNC, 10-32, and 5-44 coaxial connectors. Simply connect both ends of the cable and faults will be indicated for shield failure, conductor failure, or short circuit shield to conductor. Power is provided by a single, replaceable 9 volt battery.