Showing results: 2566 - 2580 of 5247 items found.
-
Metrix
Metrix* proximity vibration transmitters are compatible with Bently Nevada** Series 3300, 7200, and 3000 probes and cables as well as our own probes and cables. The flexible Metrix MX2034 Transmitter can be reconfigured to handle any of these probe / cable combinations.
-
Qbox -
Whirlwind Music Distributors, Inc.
The Qbox is the all-in-one audio line tester ideal for applications such as live sound, maintenance, installation work - anywhere audio runs down a cable. The Qbox can quick-check dynamic microphones and cables without firing up the entire system. It provides a handy mic or line-level tone for activating a signal path or identifying a specific cable in a pile of cable ends.
-
Tracy -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR tracy. The BAUR tracy partial discharge inductor induces a signal at the apparent fault location in the cable from outside. In combination with any PD measurement system, e.g., PHG TD/PD, the induced signal can be located and compared with the result of the partial discharge pre-location. The partial discharge location can thus be determined precisely.* Portable, battery-operated signal coupling device* Suitable for cables and cable accessories* Inductive signal coupling* Aviods costly, unnecessary replacements of PD-free cable accessories
-
PGK 25 -
BAUR Prüf- und Messtechnik GmbH
Cable testing with the BAUR PGK 25. Cables must be tested in compliance with the national and international standards. This applies before the commissioning of new cable networks. The portable BAUR PGK 25 cable test device is used for DC voltage testing in low- and medium-voltage cables. It is characterised by its low weight of only 16.5 kg, by the easy operation and solid construction for onsite use.* Compact device for DC voltage testing with negative polarity* Continuously adjustable output voltage* Perfect for mobile use
-
60-984-001 -
Pickering Interfaces Ltd.
The 60-894 provides a simple an effective method of joining two LXI WTB bus cables together to extend the length of available cables. It is an ideal solution for cable extension where users need to experiment with different cabling solutions without having to totally replace the cables in the system. The 60-894 provides mating connectors for the WTB on each end connected together by a set of accurate differential transmission lines to avoid additional reflections on the cable. The 60-894 is entirely passive and is compatible with the LXI specification.
-
Shanghai Fibretool Technology Co.,Ltd.
1. This stripper is suitable for stripping duplex and multi-core Fiber Cables: 4 cores ×1.2mm cables and 2 cores ×1.8mm and other optical cables.2. 2~4 core cable can be stripped by one operation3. Cable stripping length is adjustable from 5 mm-42 mm4. All cutting surface are precision formed, hardened, tempered and anti-rust 5. The comfort anti-fatigue design handle ensures long-term workmanship 6. Length: 161 mm, weight: 145.50g
-
TR300 Series -
Shenzhen Sharingtek Communication Co., LTD
●Determine fiber optic cable or fiber optic s failure point connection point breakpoint position ●Describe fiber optic cable or fiber s loss distribution curve measure cable fiber s length and the loss attenuation coefficient between two points●Measure fiber optic cable optical fiber connector s insertion loss●Measure fiber optic cable optical fiber s reflection loss●Light with smaller Size handheld●VFL function is optional
-
Dynamic Load Monitoring Ltd.
The Jamming Grapnel can be used as part of a longer grapnel train for clearing the route prior to laying a cable or recovering a subsea cable.
-
-
IRG 4000 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR IRG 4000. The IRG 4000 time domain reflectometer is integrated in BAUR cable fault location systems and is used in combination with the system software for locating cable faults in single and three-phase cable systems. Thanks to the novel operational concept, cable faults can be located more rapidly and easily with IRG 4000. The high-performance industrial PC and improved measurement parameters allow for a precise cable fault location in all cable types. The well-proven and continuously enhanced methods are available for the cable fault location as well as the newly developed Conditioning SIM/MIM** method which makes it even more effective and quick to locate wet cable faults that are difficult to detect. The SIM/MIM technology with 20 reflection measurements per HV pulse allows for selecting the best reflection image for a very precise determination of the fault distance.* Easy operation thanks to intuitive operational concept*Maximum precision with high resolution and sampling rate*Precise fault location methods for every type of fault
-
Platinum Tools
Offers a complete solution to test and speed certify the data-carrying capabilities of Ethernet network cables up to 1 Gb/s by testing for noise in the network, detecting faults in the cable wiring, and ensuring that cables are able to support the speed capabilities of active equipment.
-
C104DFR-2SB-1A -
Pickering Interfaces Ltd.
This 104-pin female D-type connector allows users to create their own cable assemblies. Cable connection is via solder buckets - supplied with rear cable entry backshell. This connector is suitable for use with Pickering modules that use the 104-pin D-type connector.
-
A994 -
AGM Elettronica
The A994 is an open circuit locator for electric and telephone cables wind on the reel; it gives the position of the fault from the inside or outside end of the cable, in percentage to the total cable length. The instrument measures the ratio of the capacitances of the two sections of failed conductor using two high precision i/v converters. The advantage of this method is due to the fact that the measurement error depends almost exclusively on the dimensional inhomogeneity of the cable. The A994 has the unique feature to permit the location of fault in cables with all broken wires. This instrument locates breaks in cables with a total capacity between 2 nF and 5 uF. The distance to fault is displayed on a large LCD display.
-
SLT 1 -
Maschinenbau Haldenwang GmbH & Co. KG.
Mobile handheld device with illuminated display and keypad for K-value determination and speed limiter function testConnector for multi-function plug (incl.)Adapter cable for VDO Kienzle tachograph TCO 1314Adapter cable for VDO Kienzle tachograph KTCO 1318, TVI 8400Adapter cable for VDO Kienzle tachograph FTCO 1319 TVI 2400Adapter cable for VDO Kienzle Tachograph MTCO 1324Adapter cable for Motometer tachograph EGK 100Earth terminal cable with clampPower supply 230 V / 50 Hz with 12 V DC charging voltageBoard power adapter 12/24 V DC 12 V DC charging voltagePlastic case
-
TM530 -
T&M Tools Limited Co
TM530 Audio Frequency Generator is provided with Pinpoint Fault Locator for pinpointing the low resistance fault and detecting cable route. When detecting, TM530 will inject a signal current of 1kHz audio frequency into the cable, and accordingly a magnetic wave of the corresponding frequency will be generated on the cable. Pinpoint Fault Locator will collect this magnetic signal, thus obtains the information of the cable fault and the route.