Showing results: 616 - 630 of 1906 items found.
-
Extech RF40 -
Extech Instruments Corporation
This portable battery coolant/glycol Refractometer is easy to operate refract meters provide accurate and repeatable measurements on easy to read scales. The RF40 measures the freezing point of automotive coolants (propylene glycol and ethylene glycol) and indicates the specific gravity of battery acid and provides a quick reference of battery charge condition. Complete with one year warranty, case, calibration screwdriver, plastic pipette and calibration solution.
-
Extech RF15 -
Extech Instruments Corporation
The Extech RF15 measures the concentration of sugar in fruit juice and industrial fluids from 0 to 32 percent Brix, with a maximum resolution of 0.2 percent Brix and automatic temperature compensation. It only requires two or three drops of solution, and the prism and lens with focus adjustment provides simple, repeatable measurements. The RF15 comes complete with case, calibration screwdriver, plastic pipette and calibration solution.
-
U9391G -
Keysight Technologies
The Keysight Technologies, Inc. U9391G comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
U9391C -
Keysight Technologies
The Keysight Technologies, Inc. U9391C comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
U9391F -
Keysight Technologies
The Keysight Technologies, Inc. U9391F comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
Extech Instruments Corporation
Multifunction Process Calibrator sources and measures Thermocouples (J, K, and T), mA, mV, and V devices. The 24V Loop Supply drives current loads up to 1000 ohms. Memory for 5 user settable output values of each type for fast calibrations. Single/continuous step function for Voltage and Current. Comes complete with six AA batteries and calibration cable with spade lug terminals.
-
MicroSafe 500 & 600 Series -
Teledyne Gas & Flame Detection
MicroSafe 500 and 600 Series gas detectors feature a non-intrusive operator interface. Calibration and programming instructions appear in simple intuitive and sequential script on a 16-character backlit display. The transmitter design incorporates extensive fault diagnostics with each condition conveniently identified on the transmitter display.The 500 Series comes standard with a linear 4-20 mA output, one-man remote calibration, self-adjusting zero and span, and LED indicators for fault and calibration status.The 600 Series includes the same features as the 500 with the addition of 3 alarm relays and an RS-485 serial communications port.Electrical Classification - Explosion proofClass I, Div 1, Groups B, C, D
-
Edgetech Instruments
Edgetech Instruments'' portable calibration system offers the highest accuracy available for both relative humidity and temperature. Using chill mirror technology and precision PRT's, Edgetech''s calibrators offer best repeatability, stability and reliability when measuring RH and temperature. The calibrators are used mainly by calibration labs as a reference standard.The Edgetech Instruments dew point generator, DewGen, another calibration lab favorite, can be used as a stand alone or with a NIST traceable chill mirror dew point system creating very accurate dew points or frost points. Depending on the dry gas source this generator can create dew points from +15C to -80C.
-
pH 6+ -
Thermo Scientific
Multi-Point Calibration (up to 3 points) with Auto-Buffer Recognition - choice of USA, NIST or pure water buffer standards with ±0.01 pH accuracy
-
pH 5+ -
Thermo Scientific
Multi-Point Calibration (up to 5 points) with Auto-Buffer Recognition - choice of USA, NIST or pure water buffer standards with ±0.01 pH accuracy
-
WK-8 -
ECO-TECH
Multichannel Acoustic Calibrator Type WK-8 is designed for calibration of multichannel acoustic measurement systems equipped with a half-inch measuring microphones in the field conditions.
-
Rhopoint Instruments
60 degree glossmeter for general gloss measuring applications such as print, packaging, paint. 2 year warranty, NIST traceable calibration standard.
-
ATAL
Robust temperature transducerWith integrated Pt1000 sensorOutput signal 0-10VTemperature range -30 to 80 CPower supply 15-30Vdc / 24VacSupplied with calibration certificate
-
C0111 -
COMET SYSTEM, s.r.o.
Audio and optical alarm of measured temperature. LCD backlight. Minimum/maximum memory. Memory of minimum and maximum temperature included traceable calibration certificate.
-
Ut4623 -
Bee Instruments
Programmable via detachable Programming Unit (UT4624), process calibration, signal and relay simulation, password protection, errordiagnostics and selection of help text