Showing results: 1231 - 1245 of 1874 items found.
-
CLM-1000E -
Greenlee Tools
*Measures these metric wiresizes: 0.75, 1, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95,120, 150, 185, 240, 300, 400,500 mm2*Eight user-programmable settings for other sizes*Powered by (6) 1.5V AA batteries*Replacement calibration rods (pair) available as CLM-ROD, UPC 02721*Replacement Kelvin clips (pair) available as CLM-CLIPS, UPC 02722*Meters
-
RESON TC 4033 -
Teledyne Marine RESON B.V.
The TC4033 provides uniform omnidirectional characteristics within the full frequency range of 1Hz to 140kHz. The Typical sensitivity of -203dB re 1V/µPa and the capacitance of 7nF, ensure an excellent signal to noise ratio, thereby allowing TC4033 to be used with extension cables with only a limited reduction in sensitivity. The TC4033 offers excellent acoustic characteristics and durability, which makes it ideal for a wide range of applications and for calibration purposes.
-
HFM-301 / HFC-303 -
Teledyne OEM Solutions
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
FISCHERSCOPE X-RAY/XAN 500 -
Helmut Fischer AG
Mobile measurement of coatings on large parts such as housings, machine components or pipes Stationary measurement on small parts; the compact carrying case transforms the device into a complete desktop unitThree-point sample support ensures safe, and repeatable measuring, and accommodates curved surfacesTime-effective measurement even without calibration due to FISCHER's fundamental parameterEvaluation and presentation of measurement data on a tablet PC (via Bluetooth) using the proven software WinFTM
-
AQMS-1000 -
Focused Photonics Inc.
FPI’s ambient air monitoring system consists of a sampling subsystem, a gas dynamic calibration subsystem, a meteorological parameters monitoring subsystem, a standard parameters monitoring subsystem, and a data acquisition and processing subsystem. It can monitor conventional air pollutants such as SO2, NO, NOX, CO, O3, PM2.5, PM10, etc. FPI also provides compact AQMS, micro AQMS, and mobile stations applicable to various customer needs.
-
Brighton Electronics
Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available
-
MT-4617 -
Prokit's Industries Co., Ltd.
Measures the visible light produced by fluorescent lamp, metal-halide lamp, high voltage sodium lamp or electric incandescent lampBuilt-in precision photo diode sensor and color correction filterAutomatic and manual measured range switchingRelative and peak value measurementMeasures up to 200,000 lux / 20,000 FCExtra functions: Max./Min. value displayOver load indication/Low battery indicationAuto power offBacklightData hold, Zero calibration
-
DVTest Inc.
The DVTEST LD Positioner is a two-axis elevation over azimuth positioner, for precise angular positioning with full spherical coverage. The LD Positioner is designed for the precise characterization of lightweight devices. The positioner is constructed from a low-permittivity polymer, for minimal reflections and multipath. For increased accuracy, the motor is outfitted with an absolute encoder, and laser guided calibration. A USB controller is included, with the positioner operated via Python or Matlab software libraries.
-
137 -
Edgetech Instruments
The Edgetech Instruments Model 137 Vigilant Aircraft Hygrometer is a rugged, shock mounted military qualified instrument used for the primary measurement of dew point in flight or in installations with existing flow, such as wind tunnels.It features a miniature remote dew point sensor employing a platinum resistance thermometer, and has 15 feet of interconnecting cable to the control unit. Precision calibration units for the linear analog outputs are included.
-
HFM-301 / HFC-303 -
Teledyne Hastings Instruments
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
783740-01 -
NI
100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
779012-01 -
NI
100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The NI‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The NI‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
MS 1118 -
Meltronics Systemtech
Test Set-A calibration unit is a test jig is used to simulate parameters of Adour 804E and 811 engines of Jaguar aircrafts. It simulates current, voltage, speed, and turbine gas temperature. It performs NL Check, NH Check, TGT1 (Non T2 Compensated), TGT2 (T2 Compensated), Amp (Non T2 Compensated), Amp (T2 Compensated), Solenoid Volt, TGT Inject, NL Inject, and NL/TGT Redatum.
-
E9300B -
Keysight Technologies
Measure the average power of all modulation formats Wide dynamic range power measurements from -30 dBm to +44 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
E9300H -
Keysight Technologies
Measure the average power of all modulation formats Wide dynamic range power measurements from -50 dBm to +30 dBm Frequency range 10 MHz to 18 GHzLow SWR for reducing mismatch uncertainty Calibration factors, linearity and temperature compensation data stored in EEPROM Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters