Showing results: 1246 - 1260 of 1906 items found.
-
RjP-600 Series -
Laser Probe Inc.
The RjP-600 Series energy probes integrate the detector and preamplifier in the same enclosure, thereby maximizing signal integrity between the detector and preamplifier. This permits longer cable runs between the probe and instrument, as is often necessary in production environments. Probe specific information, like calibration date and wavelength response curves, is stored in the probe for access by the instrument. Other features include interchangeable filter holders and ¼-20 mounting hole.
-
Smartech Inc.
Cannot measure pressure with fine precision by mechanical gauges, switch to Digital Pressure Gauges from SMARTECH INC and measure pressure more accurately & precisely. Get accuracy upto six times more compared to analog gauges and high resolution with least count upto 0.001 kg/cm2 / bar. Ideal for laboratory use, pressure gauge calibration and applications requiring high accuracy, precision and repeatability.
-
Applied Image, Inc.
The SM Series of Stage Micrometer Calibration Standards is ideally suited for calibrating optical, imaging, video as well as reticle based measurement systems. Designed for ease of use and manufactured for durability, the SM Series has both English and Metric scales in one or two axis configurations. Our SM series covers a range of low to high power systems, and can always be custom manufactured to perfectly fit your needs.
-
UltrapenX2™ PTBT4 -
Myron L Company
*Accuracy of up to ±0.3 ppm FCE*Calibration with pH and ORP Standard Solutions*Automatic Temperature Compensation*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Waterproof*Powered by One N Type Battery (Included)
-
DM393 -
UEi Test & Measurement Instruments
The DM393 is one of our safest Industrial Duty meters ever made. All inputs, ranges and functions protected to CATIII 1000 Volts. Perfect for HVAC and electrical technicians whose applications require higher accuracy measurements and True RMS precision. Built-in temperature means one less instrument to bring to the job. The DM393 has convenient access to battery and fuses without breaking calibration seals
-
CLM-1000E -
Greenlee Tools
*Measures these metric wiresizes: 0.75, 1, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95,120, 150, 185, 240, 300, 400,500 mm2*Eight user-programmable settings for other sizes*Powered by (6) 1.5V AA batteries*Replacement calibration rods (pair) available as CLM-ROD, UPC 02721*Replacement Kelvin clips (pair) available as CLM-CLIPS, UPC 02722*Meters
-
RESON TC 4033 -
Teledyne Marine RESON B.V.
The TC4033 provides uniform omnidirectional characteristics within the full frequency range of 1Hz to 140kHz. The Typical sensitivity of -203dB re 1V/µPa and the capacitance of 7nF, ensure an excellent signal to noise ratio, thereby allowing TC4033 to be used with extension cables with only a limited reduction in sensitivity. The TC4033 offers excellent acoustic characteristics and durability, which makes it ideal for a wide range of applications and for calibration purposes.
-
HFM-301 / HFC-303 -
Teledyne OEM Solutions
The HFM-301 / HFC-303 meters and controllers have flow ranges from 0-25 slm to flows of 0-1000 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. With a choice of elastomers and high pressure options, the HFM-301 / HFC-303 services a wide variety of applications. Cleaning for oxygen service is available.
-
FISCHERSCOPE X-RAY/XAN 500 -
Helmut Fischer AG
Mobile measurement of coatings on large parts such as housings, machine components or pipes Stationary measurement on small parts; the compact carrying case transforms the device into a complete desktop unitThree-point sample support ensures safe, and repeatable measuring, and accommodates curved surfacesTime-effective measurement even without calibration due to FISCHER's fundamental parameterEvaluation and presentation of measurement data on a tablet PC (via Bluetooth) using the proven software WinFTM
-
AQMS-1000 -
Focused Photonics Inc.
FPI’s ambient air monitoring system consists of a sampling subsystem, a gas dynamic calibration subsystem, a meteorological parameters monitoring subsystem, a standard parameters monitoring subsystem, and a data acquisition and processing subsystem. It can monitor conventional air pollutants such as SO2, NO, NOX, CO, O3, PM2.5, PM10, etc. FPI also provides compact AQMS, micro AQMS, and mobile stations applicable to various customer needs.
-
Brighton Electronics
Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available
-
MT-4617 -
Prokit's Industries Co., Ltd.
Measures the visible light produced by fluorescent lamp, metal-halide lamp, high voltage sodium lamp or electric incandescent lampBuilt-in precision photo diode sensor and color correction filterAutomatic and manual measured range switchingRelative and peak value measurementMeasures up to 200,000 lux / 20,000 FCExtra functions: Max./Min. value displayOver load indication/Low battery indicationAuto power offBacklightData hold, Zero calibration
-
DVTest Inc.
The DVTEST LD Positioner is a two-axis elevation over azimuth positioner, for precise angular positioning with full spherical coverage. The LD Positioner is designed for the precise characterization of lightweight devices. The positioner is constructed from a low-permittivity polymer, for minimal reflections and multipath. For increased accuracy, the motor is outfitted with an absolute encoder, and laser guided calibration. A USB controller is included, with the positioner operated via Python or Matlab software libraries.
-
SGS H & SGS V -
Shanghai Jiuzhi Electric Co., Ltd.
The sphere gap type SGS H or SGS V can be used for Impulse, AC and DC voltage calibration according to the IEC 60052 recommendation.The spheres are arranged vertically or horizontally, one being mobile. In the vertical version the mobile sphere is remotely adjusted by using an electrical drive. In the horizontal version, both spheres are mounted on columns of insulating materials, hence enabling to superimpose impulse AC and DC voltages.
-
137 -
Edgetech Instruments
The Edgetech Instruments Model 137 Vigilant Aircraft Hygrometer is a rugged, shock mounted military qualified instrument used for the primary measurement of dew point in flight or in installations with existing flow, such as wind tunnels.It features a miniature remote dew point sensor employing a platinum resistance thermometer, and has 15 feet of interconnecting cable to the control unit. Precision calibration units for the linear analog outputs are included.