  • Coaxial Fixed Attenuator, DC to 12.4 GHz

    8493A - Keysight Technologies

    The Keysight 8493A coaxial fixed attenuator provides precision attenuation, flat frequency response, low SWR over broad frequency range at a low price. The attenuator is available in nominal attenuations of 3 dB and 6 dB, also 10 dB increments from 10 dB to 30 dB. This attenuator is swept-frequency tested to ensure it meets specifications at all frequencies. Calibration points are provided on a nameplate chart attached to each unit.

  • Single Phase Meter Test Bench

    Supreme Instrument Laboratories

    Single phase meter test bench suitable for calibration & testing of AC Ammeters, AC Volt Meters, AC Single phase Energy Meters, Power Factor Meters & Watt Meters. Other Technical Specifications are as under

  • Frequency Generation

    Quartzlock (UK) Ltd.

    Quartzlock time and frequency generators offer a complete range of cost effective and low noise sources for a variety of applications. These acurate time and frequency generators are used in telecoms, aviation, nautical and precision test and calibration measurement enviroments.

  • Portable Accelerometer Test System

    AT-2050 - Agate Technology

    AT-2050 was designed as a next generation portable vibration calibrator and shaker table. It is capable of providing precision calibration of a wide variety of vibration and motion sensors without the external power or meter requirements that are commonly found on other models.

  • Cross Voltage Testers

    Compliance West USA, Inc

    designed to perform the 60 Hz power line cross test/AC power fault tests required in GR 1089 issue 6 table 4.5 surge test 3,4, 4.3,and 6, and for UL 1950 section 6.4 paragraph 3 and 4.. Preset and Adjustable Time Settings Measuring Terminals including Voltage Sense and Current Shunt portals provide a safe location for users to accurately measure test voltages and output current while setting up tests. Calibration of the Mini_PT-600 is designed to be performed with a simple handheld multi-meter and the removable Currents Shunts can be easily sent to a calibration laboratory if required.

  • Geo Analyzer

    ElvaX Geo - Elvatech Ltd.

    Instant on-site elemental analysis is one of the necessities of the modern mining industry. ElvaX Geo offers you accurate data and ease of operation during geo exploration or quality assurance. The instrument is designed specifically for long non-stop convenient operation. The unique 800 mm2 analytical spot analysis increases averaging of inhomogeneous samples. A composite pole helps you keep a comfortable body position during operation and enables you to analyze hard-toreach places. This form factor allows for uninterrupted measurement during slow walking while measurement results are communicated to the operator through headphones. ElvaX Geo is operated through a PDA in a protective enclosure, which can be put underneath outer garment in case of extreme climatic conditions. The Li-Ion Battery can be hidden as well. ElvaX Geo software uses both the Fundamental Parameters and the Empirical Calibration Methods. Fundamental parameters analysis of unknown samples without empirical calibration is remarkably accurate. However every instrument is calibrated for the basic mineral types with NIST or NIST traceable samples. ElvaX Geo demonstrates excellent limits of detection and repeatability.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Ion 700 Benchtop Meters

    OAKTON Instruments

    Oakton benchtop 700-series meters are designed for use in crowded laboratory settings. Compact footprint of less that 6" x 7" (16 x 18 cm) conserves valuable space, while the large, dual-display LCD provides excellent visibility—even from a distance. Ion 700 meter measures pH, mV, relative mV, ion concentration and temperature. Automatic temperature compensation (ATC) maintains reading accuracy even with fluctuating temperatures. Models feature five-point pH calibration with automatic buffer recognition for both USA (pH 1.68, 4.01, 7.00, 10.01, 12.45) and NIST (pH 1.68, 4.01, 6.86, 9.18, 12.45) pH buffers. Meters additionally feature ion concentration calibration of up to 5 points. Meter features include Auto-Hold, selectable °F or °C measurement, and easy recall of electrode slope or offset. The convenient pull-out quick reference card keeps procedures handy at all times. Use 700-series meters with any pH, ORP, or ISE electrodes with a BNC connector.

  • CO Monitor

    AI-1200 - Airspace Monitoring Systems

    AGS with Snif technology, and now with a backlit LCD display, the 1200 monitor will accurately measure and display CO levels from 12 ppm to 250 ppm. It also includes alarms like the 1100 with a panel of flashing lights and 92 decibel audio that begins at 30 ppm and grows in intensity to 120 ppm. The Snif technology provides an update every 4 seconds when in alarm to help you find the source, see the trend and otherwise manage the CO event. Like all of our V2 models, it now has a motion switch option built into it. When motion switch management is chosen, the monitor will turn itself on by any movement and if it doesn't sense CO or hasn't moved in 45 minutes, it will shut itself off. The motion switch allows passive screening capability that can dramatically stretch your battery life without risk of forgetting to turn the monitor on or off. Like all of our monitors, there is no routine bump testing or calibration required and the monitor is warranted for five years, even the sensor and its calibration is included in the warranty.

  • Handheld Optical Power Meter

    X5001 - Shinho Company

    Optical power meter X-5001 is designed to meet the high demand. It intergrades the handheld optical power meter and the intelligent optical power meter in one unit. It can be used for the absolute power measurement and relative measurement of the link loss in dB. Its compact size, friendly operation interface, broad power measurement range, high precision and brand-new user automatic calibration function and high performance in application makes it an ideal tool for optical fiber network.

  • Intelligent Pressure Calibrator

    Huaxin instrument (Beijing) Co., Ltd

    Here at Huaxin, we offer a selection of HS602 and HX601B intelligent pressure calibrators. They are high pressure, single range digital pressure calibrators with HART communication capability. Composed of high precision measurement chip, 24V DC power supply, battery charging protection circuit, HART communication module and intelligent digital pressure module, these two pressure calibrators provide a pressure calibration solution for gauges, transmitters, and switches over a wide pressure range.

  • Mobile sound Level Meter

    SoundMeter - Faber Acoustical, LLC

    SoundMeter turns your iOS device into a handheld sound level meter (SLM) with support for exponential-time-weighted sound level (Lp) and equivalent sound level (Leq) measurements with various time and frequency weightings. The built-in signal generator tool can be used for generating calibration test tones, noise, chirps, or other periodic signals. SoundMeter also offers additional tools via in-app purchase, including a Noise Dosimeter and a whole or 1/3-octave real-time analyzer.

  • Power Probes

    RkP-400 Series - Laser Probe Inc.

    The RkP-400 Series probes consist of a compact head containing the detector and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1” (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.

  • Propeller Meters

    Sparling Instruments

    Measures accurately over a flow range of 10:1 or greater.± 2% of rate accuracy, guaranteed by certified wet calibration at three test points in.Sparling’s National Institute of Standards and Technology (NIST) traceable hydraulic flow lab.Sturdy cast or fabricated steel construction.Operating temperatures are over 100° F(unless higher temperature construction is specified).Suspended solids are over 0.5% of volume.Easily maintained with standard tools.Registration can be furnished in any standard Engineering Unit.