Filter Results By:

Products

Applications

Manufacturers

Calibration

maintains accuracy of test asset by correcting out of specification conditions.

See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References


Showing results: 1471 - 1485 of 1874 items found.

  • Fully Automatic Transformer Oil Test Set

    OTS-A series - The Motwane Manufacturing Company

    OTS-A series is fully automatic microprocessor based transformer oil test set designed with advanced features to measure breakdown voltage of insulation oil accurately. The OTS-A Series preprogrammed with worldwide acceptable standards.The user can define customized standards. The large LCD display with menbrane key pad for easy operation. It is provided with internal memory for 100 data storage & built-in thermal printer for onsite report. The kit is protected by automatic detection of poor input ground.The acrylic oil test vessel provided with adjustable electrode gap setting. The voltage calibrator for on site calibration saves cost & time of user.

  • Gas Analyzers

    PCE Instruments

    Here you will find gas analyzers that meet industry standards relating to personal safety and that are mainly used to detect and measure levels of methane, hydrogen sulphide, carbon monoxide, oxygen and 50 other gases. The auto-calibration function allows for easy calibration. Some of them also possess the ability to store values and can later transfer data to a computer. One accessory is the manual aspirator, with this device, you can draw gas directly into the analyzer via a 2 m long tube with which you will be able to measure gas levels without having to be in direct contact to the gas source or to be able to determine the levels of gas in places that are difficult to access.

  • Milk Analyzers

    MRC ltd.

    Measuring parameters: FAT 0.01% - 25%SNF 3% - 15%Density 1015 1040kg/m3Proteins 2% - 7%Lactose 0.01% - 6%Water content 0% - 70%Temp. of milk 1C 40CFreezing point - -0.400 0.700CSolids 0.4 1.5%1. Sample visualization onLCD display(green)2. Possibility to measure 1 sample 90 seconds(option 60 seconds)3. Adapter 220-110 V 4.Spare silicone tubes5. Syringe6. Plastic sample holder7. Calibrations Cow, Sheep, and UHT milk8. Operation Manual9. Cardboard transport case10. CD Service PackMeasuring time 30s

  • Primary Flow Elements

    WIKA Alexander Wiegand SE & Co. KG

    Orifice plates, meter runs, flow and Venturi nozzles, Venturi tubes, pitot tubes and restriction orifices are part of our portfolio of primary flow elements. All our primary flow elements are designed in accordance with the principles and requirements of international standards (ISO 5167/ISO TR 15377, ASME MFC, ASME PTC6, BS 1042, DIN 19206, UNI 10023). We offer calibration certificates in accordance with the ASME PTC6, ISPESL and IBR standards. With our extensive product range we are in a position to cover almost all industrial applications. Customised solutions can be developed to meet your specific needs.

  • 16-Channel RTD Signal Conditioning Card

    ProDAQ 5821 - Bustec Ltd.

    The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored on-board after calibration. In order to achieve the highest accuracy the output current may be automatically calibrated 'on-the-fly' using the ProDAQ 3416 24-bit Sigma-Delta ADC card and an on-board precision resistor.

  • Portable Gas Leak Detector

    Oxygas 500 - Teledyne Gas & Flame Detection

    The Oxygas 500 compliments the Gascoseeker 500 with a similar performance, measuring % LEL and % volume flamm​able hydrocarbons, but with the addition of oxygen for either gas/air or gas/nitrogen/air purging. The Oxygas 500 has the following additional features; automated zero during start-up, manually selectable purge mode.​The P-500 variant has an additional part per million (ppm) range of methane.​​​​​​The Oxygas 500 is easy to use with very simple training, as the operation of the instrument follows the operation of the purge cycle. The rugged design allows the Oxygas 500 to be used in harsh environments. The instrument is also fully compatible with our range of calibration software and equipment.​​

  • Portable 4-Gas Monitor

    PS200 - Teledyne Gas & Flame Detection

    The PS200 Series combines quality, ruggedness and advanced technology in a user friendly, portable gas monitor. It is compact, lightweight, water resistant, extremely robust, and is certified to multiple international and regional standards.The PS200 can measure any combination of LEL, ​O2, CO and H2S making it suitable for a wide range of personal monitoring and confined space applications.In addition to extensive datalogging capabilities, the PS200 is available with an optional internal pump and an extensive range of accessories to meet a wide variety of user applications.Importantly, the PS200 has been des​​igned to enable easier user maintenance which includes a fully automatic calibration station to simplify product compliance.

  • Shallow Water Multibeam Echosounder

    MB2 - Teledyne Marine RESON B.V.

    The MB2 Multibeam Echosounder is developed for fast mobilization on smaller vessels and is optimized for shallow water survey companies, Port and Harbour Authorities, dredging companies and other users looking for an easy to use, quick to deploy, high resolution system.As an option MB2 can be supplied with an integrated IMU and GPS heading system as well as an integrated real-time SVP sensor to simplify installation and calibration, making the MB2 perfect for use on vessels of opportunity, small survey launches and ASVs.MB2 features a dedicated cylindrical transmit array and broad range of sounding frequencies improving on the performance of the MB1 by offering a wider coverage and narrower acoustic beam.

  • Strip Tension Measurement

    ABB Ltd.

    ABB’s strip tension system is the perfect choice for measuring strip tension in hot rolling, cold rolling and process lines.Accurate strip tension measurement is a prerequisite for keeping the strip tension constant within the desired range, during both acceleration and deceleration. This allows for optimal strip quality, increasing process uptime and preventing strip breaks. The system is proven to be exceptionally robust and resilient to high forces as well as aggressive mill agents. The load cells are calibration free, can withstand overloads up to 10 times the nominal force, and have an impressive life length. The load cells come in different sizes up to 200 kN.

  • CORROSION GAUGE

    MMX-7 - Dakota Ultrasonics

    The MMX-7 has all features of the MX & MMX gauges with some additional features and advantages. Selectable Large Digits and B-Scan display options. An internal data logger that stores a total of 12,000 readings and waveforms, 64 user custom definable setups, selectable transducer table for improved linearity, thru paint mode with the single press of a button, multiple calibration and material selection options, and selectable low, medium or high gain options. This is all nicely packaged in a very mini portable aluminum extrusion for extra durability and portability! The MVX/PVXview or Java-based PC software makes this thing a complete kit and then some! 2-year limited warranty.

  • Digital Brix Refractometer - for Measuring Dissolved Sucrose in Liquids

    Extech RF153 - Extech Instruments Corporation

    Take quick and accurate % Brix or Refractive Index (RI) measurements of dissolved sucrose level in liquids for beverage and food production, determine maturity of fruits and plants, or control the concentration of industrial fluids (such as cutting coolants, hydraulic fluids, and antifreeze) to extend equipment life and prevent corrosion. Fast three second response time, the LCD displays %Brix or RI and Temperature. The RF153 fits in the palm of your hand and it features built-in ATC, single Zero calibration, prism cover, and auto memory storing 10 readings. Rugged low maintenance water resistant (IP65) housing with convenient side spouts for easy drainage.

  • Fast Response Flow Controller for Low Flow

    HFM-300 / HFC-302 - Teledyne Hastings Instruments

    The all metal HFM-300/HFC-302 is Teledyne Hastings' metal sealed, fast response series of mass flow meters and controllers. Featuring reliability and stability, the 300 Series is chosen by OEM's for its fast response under a wide range of conditions. .The HFM-300 / HFC-302 meters and controllers have flow ranges from 0-5 sccm to flows of 0-25 slm; provide analog outputs, are constructed of stainless steel and have normally closed valves. The full scale range is specified by the end user. A NIST traceable calibration certificate is standard. Corrosive gases and pressures up to 1000 psig are easily measured. Cleaning for oxygen service is available.

  • MIPI Receiver Test Solution

    M8085A - Keysight Technologies

    The M8085A is a software plug-in for M8070A Bit Error Ratio Test system software within the M8000 series of BER test solutions. The M8085A software plug-in controls either the M8190A or the M8195A Arbitrary Waveform Generators to create C-PHY or D-PHY standard compliant test signals. In addition it provides routines for calibration of all signal parameters and for all tests specified in the applicable Conformance Test Suite. Together with the additional available DUT control interface it is possible to read the BER of the receiver under test from the M8070A software and display the BER dependency from test parameters within the M8070A user interface.

  • Spectroscopic Reflectometer

    SR Series - Angstrom Sun Technologies, Inc.

    Spectroscopic reflectometer (SR) series are relative low cost and easy to use tools. To enusre accurate measurement on spectra, a long working distance and also adjustable working distance set up are professionaly desgined and considered. Since reflection spectra measurments require to use known reference to calibrate light intensity, it is hard to image user could get accurate spectra without optimizing signal step during such calibration because reference thickness is different from sample substrate's thickness in most of cases. Adjusting power output to lamp is our another consideration in ensuring a good measurement by reducing non-linearity effect of the detector

  • Meter Test System

    MTS-50 - Kongter Test & Measurement Co., Limited

    This meter test equipment features state-of-art designing with high accuracy. It is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 50A). This system is particularly designed with modular structure for calibration and test of different single phase/3 phase electronic/inductive active and reactive energy meters.

Get Help