Filter Results By:

Products

Applications

Manufacturers

Showing recent results 211 - 225 of 247 products found.

  • PMR Power Meter

    COMM-connect

    The 3030 RF Power Meter is a modern version of the traditional Antenna Watt and VSWR instrument. The instrument cover communication bands from 30MHz to 500MHz. The 3030 RF Power Meter will measure forward and reflected power in the range from milliWatts up to 100Watts. Built in frequency counter. The counter will show the transmit frequency and will call the calibration table for the actual frequency. Outside the range of the counter the instrument can be set into manual mode giving a wider dynamic range. The 3030 RF Power Meter will calculate VSWR or Return Loss, and features Peak and Hold mode. Accessory kit with soft or hard carrying bag, car charger and coax adapters for standard types are available

  • Worksoft Analyze®

    Worksoft

    Worksoft Analyze is an easy-to-use solution that enables automation professionals to discover actual end-to-end business processes without having to ask someone how it’s done. Worksoft Analyze eliminates not only the need for user interviews but also all the resulting manual documentation. This drastically reduces manual labor and can cut weeks or even months from the overall project timeline. Best of all, because the business processes are now defined and documented within the system, you can use them to jump-start test automation efforts by importing them as test scripts into Worksoft Certify or even as business blueprints in SAP. We call this business-driven automation!

  • Residual Intensity Calibrator

    CAL291 - Larson Davis, Inc.

    Under IEC and ANSI standards, a sound intensity measuring system consists of a two microphone sound intensity probe and a dual channel processor. The accuracy of the intensity measurement is strongly dependent upon the phase accuracy between the two measurement channels, including the microphones. Sound intensity measurement systems are classified into Class 1 or 2 based upon the pressure-residual-intensity index which is measured using a residual intensity testing device. For direct calibration or verification of the accuracy of a sound intensity measurement system, IEC 1043 and ANSI S1.9 call for the use of a sound intensity calibrator which delivers to the probe microphones the simulated intensity at a specified temperature, atmospheric pressure and nominal microphone separation.

  • Axia Audio

    Linear Acoustics

    The foundational technology in all Axia products is Livewire plus AES67—we call it Livewire+—an AoIP protocol that enables high-reliability, low-delay uncompressed digital audio over Ethernet, including audio, logic, control, and program associated data (PAD). Devices connect together using standard Ethernet cables; audio and control routing is accomplished with off-the-shelf Ethernet switches. Axia Livewire+ has built-in compliance with the AES67 standard. That's because Axia and the Telos Alliance are committed proponents of AoIP interoperability—first as charter, supporting members of the X192 Working Group that defined AES67, and now as founding members of the Media Networking Alliance, a group of prominent equipment manufacturers formed to actively promote the adoption and implementation of the AES67 standard.

  • Portable Dynamometers

    Custom Portable Solutions - Mustang Dynamometer

    Mustang Dynamometer offers custom-designed portable solutions for customers looking for something unique and specific to their needs. We have made portable vehicle inspections stations for checking emissions and speedometers for many years and have designed and supplied portable systems for events and marketing campaigns. Our systems have been used to promote Harley Davidson Motorcycles, Ford’s F-150, GM’s Sierra pickup, Lexus sedans, the Toyota Tundra and many others. We have even been in a few car commercials. If you have an idea and would like Mustang’s help please call a sales specialist today at (330) 963-5400 or send us an email at sales@mustangdyne.com. We’re happy to help bring your ideas to life.

  • very fast DDoS analyzer / Open Source

    FastNetMon - Pavel Odintsov

    FastNetMon - A high performance DoS/DDoS load analyzer built on top of multiple packet capture engines (NetFlow, IPFIX, sFLOW, SnabbSwitch, netmap, PF_RING, PCAP). What can we do? We can detect hosts in our own network with a large amount of packets per second/bytes per second or flow per second incoming or outgoing from certain hosts. And we can call an external script which can notify you, switch off a server or blackhole the client.

  • Cells and Electrodes

    Bank Elektronik

    Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.

  • Coaxial Switches

    Dow-Key Microwave

    An electromechanical switch made primarily for routing microwave signals/RF energy from one point to another within a transmission line. Coaxial RF switches can be used in either an industrial environment or in the lab. These electromechanical devices are also used for RF testing equipment and in large RF communication systems and networks. Coaxial switches vary by port configuration, switch type, maximum frequency, isolation, insertion loss, voltage standing wave ratio (VSWR) and package type. Coaxial RF switches are able to route RF signals over a broad bandwidth from DC to 40 GHz, and are now offered with the Low PIM option which will improve Passive Inter modulation levels from -110dBc (standard switch) to -160dBc.Search Our Complete Line of Products – Call 805-650-0260 with any questions.

  • Digital Audio Analyzers

    WinTek s.a.s.

    As regards the activity carried out by those in the call center it is important to note that much of the noise under which a trader is directly applied to the outer ear (acoustic signal from the headphone) and not, as usually happens, is only widespread environmental noise . For this reason they are different measurement methodologies normalized been identified that provide for a correction of the measured noise spectrum waves bring the same extent equivalent to the diffuse sound field in the vicinity of the attache head. The measurement techniques normalized are two: the first requires the measuring the acoustic signal with a probe placed in the operator''s ear canal (MIRE technique) but attention difficult to enforce; the second requires the measurement of an acoustic signal to the eardrum equivalent to that to which the operator is subject by the use of a system similar to those used in headphones, powered by an equivalent electrical signal and applied to a normalized anthropometric mannequin.

  • WATOM

    KoCoS Messtechnik AG

    Wafer edge and notch profile measurementThe use of smaller and smaller patterns in the semiconductor industry calls for increasingly advanced materials of extremely high quality. In response to the steady improvements in the quality of wafers, KoCoS Automation has developed WATOM, a wafer edge and notch profile measurement tool which heralds a new era of extremely precise wafer geometry measurement.WATOM supports quality assurance throughout the wafer manufacturing process, starting at the very beginning and continuing on through to wafer reclaim.The WATOM Edge and Notch Wafer Geometry Analyser sets the worldwide benchmark for the quality assurance of geometrical measurements in semiconductor wafer manufacturing, combining the highest quality standards with top-class service. These high-precision, laser-based edge profile measurement tools are specially designed for optimum integration in manufacturing lines within the semiconductor industry.

  • LTE Emulation for End-to-End QOS Validation

    IxLoad-Wireless XAir2 - Keysight Network Applications and Security

    Ixia’s XAir2 load module provides LTE user equipment (UE) emulation that enables a powerful IxLoad eNodeB Layer 1 to 7 test solution. With complex UE modeling, it offers realistic and easily-configured traffic models and call patterns. Using IxLoad’s real-world subscriber modeling, testers do not need to be protocol experts to develop test realism. From a single tool, users can perform capacity tests, detail a cell throughput, measure voice and video quality, model a wide variety of mobility scenarios.

  • Custom Engineered Solutions

    Datum Electronics

    In many cases, it is better to use an existing shaft or test rig and convert this to be the torque sensor. This process reduces the cost of fitting a conventional torque transducer and it improves the measurements taken by maintaining the dynamics of the driveline. Datum Electronics are able to provide both modular and custom designed torque and rotary strain measurement solutions. The solutions range from an installation on a specific shaft or coupling on a test rig to the full design of an integral system for a drive system. Engineered solutions can be complete as one off or as fully integrated OEM solutions. Datum has completed over 1000 such designs and will probably have something close to what you need in our drawings library. If you would like to discuss an application where you think a custom design would be of benefit please call our technical sales team or email in a drawing or sketch of the shaft and its location.

  • DataLogger

    Hastest Solutions Inc.

    Memory capacity is 8100 lines of data per channel. (It is possible to store the data for about 506 days with log interval of 90 minutes.)The method of storing data can be selectable among four logging options. (Once, Repeatability, Ends at, By page)The date and time to start logging automatically can be specified by setting the preset start.The measurement data can be transmitted in realtime to a personal computer.USB transmission is adopted.The upper and lower thresholds for warning can be set. When the temperature or humidity threshold is triggered, the alarm mark (Hi or Lo) will light.Display Functions: TIME (display time), INT (log interval) REC (during logging). RES (during preset standby), OUT (during real-time tranmission), LCD bars (used memory) CALL (call for the current measurement data during logging) Current temperature, Current humidity, Current date and time, low battery mark, Temp. upper limit (Hi), Temp. lower limit (Lo), Humi. upper limit (Hi), Humi. lower limit (Lo), Temp. alarm ON (Alarm), Humi. alarm ON (Alarm), logging option, setting value of upper and lower limits. errer message, ID numberProbes are interchangeably used with main units.The storage memory can be varified with the memory indicator.The log interval can be selected from 14 options: 1 sec, 2 sec, 5 sec, 10 sec, 15 sec, 30 sec, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, 60 min. and 90 min.When the power is turned off, data stored in the EEPROM memory is retained.The datalogger ID can be set. This is useful to identify multiple dataloggers.By using data analysis software attached, acquired data can be evaluated easily and quickly, and also evaluated by using commercial spreadsheet software supporting the "CSV" extension such as Lotus 1-2-3 and Microsoft Excel.Software for data analysis and realtime transmission (CD-Rom)

  • PXI Strain Gauge Simulator Module 4-Channel, 1.5k

    40-265-404 - Pickering Interfaces Ltd.

    The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 4-channel, 1.5k) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions. Each simulator channel includes an independent input for the Excitation Voltage and a bridge output. The Excitation Voltage port can be driven by an AC or a DC source. The bridge circuit includes three fixed resistors and a fourth programmable resistor that can be adjusted over a narrow resistance range with fine adjustment capability and excellent accuracy. The adjustment range provided is sufficient to simulate quarter, half or full bridge circuits. The standard bridge impedances are 350, 1k, 1.5k, 2k and 3k. These modules are extremely simple to use, the variable resistor element can be programmed using a simple resistance call. The module supplies the user with the resistance value required to balance the bridge, and the resistance call to the simulator can be varied above and below this value to simulate extension and compression of the strain gauge resistor.

  • PXI Strain Gauge Simulator Module 2-Channel, 2K

    40-265-302 - Pickering Interfaces Ltd.

    The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 2-channel, 2k) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions. Each simulator channel includes an independent input for the Excitation Voltage and a bridge output. The Excitation Voltage port can be driven by an AC or a DC source. The bridge circuit includes three fixed resistors and a fourth programmable resistor that can be adjusted over a narrow resistance range with fine adjustment capability and excellent accuracy. The adjustment range provided is sufficient to simulate quarter, half or full bridge circuits. The standard bridge impedances are 350, 1k, 1.5k, 2k and 3k. These modules are extremely simple to use, the variable resistor element can be programmed using a simple resistance call. The module supplies the user with the resistance value required to balance the bridge, and the resistance call to the simulator can be varied above and below this value to simulate extension and compression of the strain gauge resistor.