  • Precision Capacitance Meter

    TH2638A - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Battery Cell Testing Equipment

    Xiamen WinAck Battery Technology Co., Ltd.

    The battery cycle life tester is a high-precisionsystem designed specifically for the battery cell charge and discharge testing.It is suitable for the battery cell cycle test, battery cell charge anddischarge aging test, battery cell performance test, battery cell capacitydetection test, battery cell IR test, deep-discharging test, function test ofhigh-power lithium-ion battery cells, such as EV battery module, ES batterymodule, super capacitor…

  • Kvar Meter

    Ajinkya Electronic Systems

    Ajinkya's KVAR METER useful for testing and measuring capacitance and Kvar of Power factor correction capacitors. The capacitance measurement is done off line and Kvar is calculated at rated capacitor voltage. Rated capacitance voltage is displayed on power on and can be set with through keyboard. It is a handy and light instrument operating directly on single phase a.c. power. It is a table top instrument which can be used in laboratories as well as can be carried out on site easily.

  • Digital Insulation Mult-Meter

    8005 IN - Standard Electric Works Co., Ltd

    ● Microprocessor controlled.● Four insulation test voltages (DC) : 50V, 100V, 250V, 500V● The maximum insulation measurement range is 200G ohm @500V.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III

  • Magnetizer

    412B - Oersted Technology

    The Model 412B magnetizer provides many of the features of the Oersted Technology 300-series magnetizers in a small benchtop cabinet. This unit is designed for magnetizing parts which require lower energy levels due to their size or the magnetic material used. Like the 300-series magnetizers, the 412B is an ECS magnetizer, which allows the user to electronically vary the capacitance of the unit. The capacitor banks are internally discharged through a safety circuit in case of power failure or accidental power-down. When the 412B is connected to a properly equipped fixture, the front-panels can be inhibited through an overtemperature interlock circuit, preventing the magnetizer from being operated once the fixture begins to overheat. An external output is also provided for monitoring the magnetizing current pulse with an oscilliscope.

  • Variable Frequency Series Resonance Test Device

    WABP - Wuhan Sangao Electrical Test Installations Limit Co.

    The device mainly AC voltage withstand test design for 10kV, 35kV, 110kV, 220kV, substation and line of all electric main equipment.Reactor with multiple separate design, Not only can meet the requirements of equipment testing conditions high voltage, small current, and can meet the requirements of low voltage AC voltage withstand test, has a wider scope of application.The device is mainly composed of variable frequency control power supply, transformer, reactor, capacitor divider.

  • Reactor Loss Measurement Systems

    Measurements International Ltd.

    The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.

  • LCZ LCR Meter

    SS1063 - Sanshine Electronis Co., Ltd.

    This (SS1061 / SS1062 / SS1063) LCZ Meters are a test system for passive components designed for the use in electronic inspection or production process for quality control. They meet any demanding requirement on production speed and precision, discrimination of qualified products from unqualified ones, as well as internal setup, storing and calling function for up to 10 instrument groups, so they Like as: transformer, inductor, resistor, capacitor, relay, motor, generator, eletric valve, contactor,cable,wire,etc.

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

  • Digital Insulation Resistance Tester (CE)

    MIS-D - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *The big digital and bar graph LCD display with back light enabled easy observation. Especially useful when working in dark place.*Hand free and continuous measurements with custom made switch.*Safe design with built in automatic discharging function for any capacitors present in the circuit.*The voltage in the circuit or capacitor can be checked by warning lamp for safe insulation measurements.*Data hold and auto power off function.*Compact, light weight and heavy duty rugged case.

  • Surge Voltage Generator

    SSG 2100 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 2100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit

  • Surge Voltage Generator

    SSG 1100 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 1100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit

  • Surge Voltage Generator

    SSG 1500 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 1500. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit

  • Transformer Oil Tester

    GTD-81 - Kingrun Instrument Co., Ltd.

    GTD-81 Insulation Oil Dissipation Factor and Resistivity Measuring System DTL, is designed and manufactured based on international standards. It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. The instrument is characterized by integrated structure, and integrates test cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components.

  • AC/DC Power Capacitors

    ACF Series - HK Film Capacitor Ltd

    For 70Vac~400Vac / 100Vdc~700Vdc Pulse Current requirement, please refer to our DC Pulse Current Capacitors for Power Electronic applications.For continuous and High RMS Current requirement, please refer to our High AC Current Capacitors LC series, which support continuous duty even at +105C.We manufacture AC Filter Capacitors for a wide variety of applications with different Capacitances, Voltages, Discharge Energy ranges, dv/dt, Pulse Discharge Currents, RMS Currents, frequency ranges, size restriction and even capacitor mountings.