Filter Results By:

Products

Applications

Manufacturers

Characterization

is defining an objects attributes and make up.

See Also: Qualification


Showing results: 376 - 390 of 435 items found.

  • Modulation Distortion Up To 26.5 GHz

    S930702B - Keysight Technologies

    S930702B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 26.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930702B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 50 GHz

    S930705B - Keysight Technologies

    S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 90 GHz

    S930709B - Keysight Technologies

    S930709B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 90 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930709B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Digital Wideband Transceiver Analysis

    S94610B - Keysight Technologies

    Digital Wideband Transceiver Analysis is an add-on software to Device Measurement eXpert (DMX) that adds cross-domain stimulus response measurements for digital/RF mixed-signal device characterization. Included Waveform Creator helps define digital IQ test stimulus waveforms that are used in the RF signal generators for receiver tests or downloaded to the digital-to-analog converters for transmitter tests. The DUT control is customizable to accommodate various data converters and transceiver types by defining device operation settings, transmit/receive switching, reading and writing digital IQ waveform from and to DUTs. Acquired RF or digital data is processed in the VNA’s applications for faster, accurate measurements and analysis.

  • Modulation Distortion Up To 13.5 GHz

    S930701B - Keysight Technologies

    S930701B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 13.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930701B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 125 GHz

    S930712B - Keysight Technologies

    S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 43.5 GHz

    S930704B - Keysight Technologies

    S930704B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 43.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To And Beyond 125 GHz

    S930713B - Keysight Technologies

    S930713B enables fast and accurate active-device modulation distortion characterization under modulated stimulus conditions up to and beyond 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930713B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • PXIe-5650, 1.3 GHz RF Signal Generator

    781215-01 - NI

    The PXIe‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXIe‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • Modulation Distortion Up To 70 GHz

    S930707B - Keysight Technologies

    S930707B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 70 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930707B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • Modulation Distortion Up To 8.5 GHz

    S930700B - Keysight Technologies

    S930700B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 8.5 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930700B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.

  • PXI-5650, 1.3 GHz RF Signal Generator

    779670-00 - NI

    The PXI‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXI‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

  • Antenna Test Chamber for Automotive Radar

    ATS1500C - Rohde & Schwarz GmbH & Co. KG

    The R&S®ATS1500C radar test chamber is a compact antenna test range (CATR), consisting of a gold-plated parabolic reflector and a two-axis positioner for 3D movements of the radar module. Combined with the R&S®AREG800A target simulator and other Rohde & Schwarz test and measuring instruments, it can be used for a variety of applications, including antenna characterization, module calibration, RF performance validation, interference testing or in-band compliance testing. The chamber is equipped with a universal feed antenna which gives access to both polarizations in parallel. Automated temperature testing over the range of -40 to 85°C is possible with an optional enclosure.

  • Soft Front Panel for NI RF Analyzers

    NI RFSA Soft Front Panel - NI

    The NI RFSA Soft Front Panel helps you quickly view and analyze RF signals using PXI hardware from National Instruments. The soft front panel features built-in measurements such as third-order intercept (TOI), complementary cumulative distribution function (CCDF), adjacent channel power ratio (ACPR), occupied bandwidth (OBW), channel power, and transmit power. With these one-button measurements, you can quickly measure, display, and store results, which makes NI PXI instruments ideal for characterization and validation environments. You can also use the NI RFSG Soft Front Panel for generating continuous waveform (CW) or modulated RF signals.

  • Test Data Investment Services

    PDF Solutions

    PDF Solutions Professional Services offerings cover every major project phase. Available for a specific phase of your project needing a custom solution, or an end-to-end implementation, PDF Solutions Professional Services produces results fast.Realize quicker ROI from your semiconductor test data investmentOffering a broad range of planning, education, design engineering, implementation and support, our team of highly trained semiconductor data integration engineers and analytics consultants can help you build your solution with confidence. These experts can assist your team with:Business Practices AssessmentsBest Practices ImplementationYield AnalysisProduct Characterization SetupSystem DeploymentSite PlanningFlow AnalysisCustom Parser Development

Get Help