Showing results: 196 - 210 of 2578 items found.
-
32900 -
Lisle Corp.
Heavy-duty circuit tester for checking low voltage up to 12 volts. By depressing the red button the tester becomes a jumper for powering electrical components or a ground. The probe, handle, cord and clamp are reinforced for durability. Comes with a strain relief spring on the cord.
-
AMZC-305 -
Amperis sl
Loop impedance measurement with resolution 0,01Ω ; Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01Ω (100...440V) ; Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
-
1668 -
Peaceful Thriving Enterprise Co Ltd
Check on 6 and 12V systems. To indicate whether there is an electrical potential at any low voltage point in the system. By using the pointed contact tip to pierce insulation on cables, it will also indicate if current is present. This can be helpful when tracing faults or add cable to a circuit.
-
1668E -
Peaceful Thriving Enterprise Co Ltd
Check on 6 , 12V and 24V systems. To indicate whether there is an electrical potential at any low voltage point in the system. By using the pointed contact tip to pierce insulation on cables, it will also indicate if current is present. This can be helpful when tracing faults or add cable to a circuit.
-
1671 -
Peaceful Thriving Enterprise Co Ltd
Check on 6 and 12V systems.1. Locate short, ground or open circuit.2. Make it easy to find out where current is present.3. The most essential for troubleshooting automotive electrical systems.4. Checks series-parallel switch and solenoid on tractor-trailer start system.
-
EM-SUPREME® -
PedaSoft LLC
Time-domain Field-Device-Circuit coupled simulator for modeling of passive structures, active components, and complete RF & millimeter-wave modules. EM-Supreme is used for EM modeling of power amplifiers, switches, filters, active antennas, and complete RF modules such as antenna-switch, switch-filter, switch-filter-amplifier, and front-end modules with no approximations.
-
1672 -
Peaceful Thriving Enterprise Co Ltd
Check on 6, 12 and 24V systems.1. Locate short, ground and open circuit.2. Make it easy to find out where current is present.3. The most essential for troubleshooting automotive electrical systems.4. Checks series-parallel switch and solenoid on tractor-trailer start systems.
-
IES Systems, Inc.
IES Systems is a turnkey test systems solution provider with 10 years of proven experience in printed circuit board testing solutions. Our experienced engineers design electro/mechanical solutions to interface between your product and our custom designed test instrumentation. We provide a complete solution to your PC board testing needs.
-
Vanguard Instruments Company, Inc.
The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field.
-
61-035 -
IDEAL Industries, Inc.
*Tests for correct wiring, open ground, reverse polarity, open hot, open neutral, hot on neutral, hot and ground reversed with open hot in 3 wire, 120 VAC circuits*Simulates ground fault for testing GFCIs*No-slip ergonomic design maximizes comfort*Premium neon lamps prevent false readings*Tough, impact-resistant case*2-year warranty
-
ACTAS C160 -
KoCoS Messtechnik AG
Stationary test system for carrying out fully automatic final factory tests, type and function tests on all kinds of switchgear devices, such as circuit breakers, disconnectors or earthing switches, regardless of the type of drive unit. All the electrical and mechanical parameters needed for the assessment of switching performance are measured in real time and evaluated without either the main contact chambers or the drive unit having to be opened. The system has analog and incremental input channels for the acquisition of analog quantities.
-
PI-800 -
ETI Precision
The PI-800 Circuit Breaker Test System incorporates modular design and flexibility to provide unequaled capability in a portable package. The PI-800 generates continuous current of 800 amps at 4.2 kVA, with peak output to over 10x, on 120 or 240 VAC supplies. The units are housed in rugged interlocking suitcase sized enclosures. Each piece weighs no more than 125 pounds, allowing one person hand truck mobility. Basic operation is very simple, and the proven MAC-21 instrumentation provides optimal output control and measurement.
-
ACCAT -
Huntron
The ACCAT is designed to support diagnostic and acceptance test requirements across a wide spectrum of testing parameters. ACCAT provides a suite of core parametric test instruments, advanced GUI based software, Huntron Access Robotic probing and Huntron Analog Signature Analysis (ASA). ACCAT provides stimulus and asurement capabilities necessary for full functional and parametric testing of circuit card assemblies along with robotic guided probes for fault verification and debug. The Huntron ASA test is ideal for pretest or safe to power up procedures protecting the integrity of the test system.
-
A910 -
AGM Elettronica
The A910 is a short circuit locator designed for fault location in power cables. The instrument measures the ratio of the resistances of the two sections of failed conductor using a four-wire "Kelvin" connection, thus eliminating errors associated with contact resistances of the test leads. With the A910 you can determine if the cable has more than a short and locate the first and the last fault. The instrument locates fault with an insulation resistance up to 5 Mohms in cables that have a total resistance greater than 5mohm (approximately 90 m of 300 sqmm cable) and less than 30 kohms. The distance to fault is measured as a percentage of the total length of cable and is displayed on a large LCD display.
-
CAT-H Series -
Amperis sl
The operation of the breaker can be initiated in different ways (e.g. from a control room, by a local breaker or externally by a test device) depending on the test conditions. Various time measurement triggers are available to record a measurement under a different test condition:*Coil control channel*Continuous current clamping channel*DC voltage channel