Showing results: 646 - 660 of 2618 items found.
-
Toellner Electronic Instrumente GmbH
In electricity generation, a generator is a device that converts motion-based power (potential and kinetic energy) or fuel-based power (chemical energy) into electric power for use in an external circuit.
-
HSCH-9161 -
Keysight Technologies
The HSCH-9161 is suitable for medium-low barrier, zero bias detector applications. The HSCH-9161 is functional through W-band (110 GHz) and can be mounted in microstrip, finline, and coplanar circuits.
-
HSCH-9162 -
Keysight Technologies
The HSCH-9162 is suitable for medium-low barrier, zero bias detector applications. The HSCH-9162 is functional through W-band (110 GHz) and can be mounted in microstrip, finline, and coplanar circuits.
-
1669 -
Peaceful Thriving Enterprise Co Ltd
Check on 6 and 12V systems, test for circuit and spark plug.1. Check spark plug on secondary or high voltage. 2. Use as a continuity tester to check on low voltage circuits.
-
GT 3100GAM -
GAM Products, Inc.
Cable test monitors line continuity, shows completed circuits. Lamp test indicates the lamp and fixture continuity. Circuit tester checks if power is available, if polarity is correct, if wiring is correct.
-
KM 1520 -
Kusam Electrical Industries Limited
*Capable of measuring earth voltage(Vac).* 2 mA measuring current permits earth resistance to test without tripping earth leakage current circuit breakers in the circuit.* Battery operated.
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2710 is a residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE). RCD testers let a fault current flow and thus determine at which fault current the RCD triggers. The tripping time is also measured. These two parameters, tripping current and tripping time, are the safety-relevant parameters of an RCD. The various selectable test currents and characteristics that can be set with this device make the PeakTech 2710 the ideal companion for every electrician.
-
ELM -
Eclypse International
Circuit breakers are often overlooked during maintenance of electrical systems in aircraft, or often only verified for open and closed states. To test the true functional purpose of a circuit breaker it requires the application of current in excess of the rated trip value and then measure the time for the breaker to actually trip. This is the only way to verify that a circuit breaker will react as designed if an electrical failure occurs.
-
Eclypse International
Circuit breakers are often overlooked during maintenance of electrical systems in aircraft, or often only verified for open and closed states. To test the true functional purpose of a circuit breaker it requires the application of current in excess of the rated trip value and then measure the time for the breaker to actually trip. This is the only way to verify that a circuit breaker will react as designed if an electrical failure occurs.
-
72-7670 -
Tenma
High current switching mode DC regulated power supply for radio equipment and high power car stereo work.*3 digit LED display of voltage and current*Overload, overtemperature, overvoltage and short circuit protection*High efficiency with light weight and small size*Current fold back circuit with LED indicator prevents overloading*Variable speed thermally controlled fan*12-month limited warranty *view Terms & Conditions for details
-
FB305M -
Matco Tools
Can test circuit current up to 30 Amps - an easy way to check fuel pump amperage. Clever design allows for easy connection into fuse sockets. Fuse Buddy ends are molded into the shape of the fuse itself. During testing the fuse is removed and replaced into the Fuse Buddy. This way, the circuit being tested maintains fuse protection. Fuse Buddy stays put & won't fall out of the socket, like test probes do.
-
MIG1212CAP -
EMC Partner AG
MIG1212CAP is specially designed for high voltage test on X / Y capacitors with impulse voltage approximate 1,2/50 µs up to 12 kV in accordance with IEC 60384-14 Ed.4. The MIG1212CAP comprises two circuits with impulse capacitance 20 µF and 0,25 µF. Both circuits generate a voltage wave shape of approximate1,2/50 µs and are combined in an 8 unit high 19" rack. IEC 60384-14 and EN 132400 define the generator.
-
3282(280V,1875W / 3700VA ) -
PRODIGIT Electronics Co, Ltd.
3282 power Factor RLC Load built-in 16-bit A/D and DSP precision measurement circuit, provides accurate measurements, measurement items have Vrms, Arms, Watt, VA, CF, PF, THD, VTHD, ITHD, Ipeak, Amax, Amin, Vmax, and Vmin. In addition to these measurement functions, it also provides time measurement,products such as UPS, fuses and circuit breakers etc. trip or blow time and transfer time for Off-line UPS
-
Naprotek, LLC.
In order to minimize filter roll-off, we start with a quality, highly polished substrate and apply layers of metallization within tight tolerances. Our highly anisotropic ion beam etching process enables us to produce features down to 10 microns. Furthermore, the milling process yields a high consistency from circuit to circuit meaning that whether we produce 1 or 100,000 filters, each one will have consistent filter roll-off characteristics.
-
1851 IN -
Standard Electric Works Co., Ltd
● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 210mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● BS 16 edition