  • ST Fully-auto BDV Dielectric Oil Tester Set

    Chongqing Assen Power Equipment Co., Ltd

    ST BDV Dielectric Oil Tester is ideal for speedy and accurate testing of dielectric strength of transformer and circuit breaker oil under-test room condition in accordance with international standard.

  • Electronics Failure Analysis (F/A)

    National Technical Systems

    NTS electronics failure analysis capabilities can be utilized to improve yield, determine root cause of failure, extrapolate life expectancy and improve reliability, and increase performance on integrated circuits (ICs), printed circuit boards (PCBs), and passive surface mount devices as well as materials and assemblies.Electronics F/A can provide detailed information regarding the performance of materials and devices in their intended end-use application. When a device or material does not meet its performance expectations, a F/A should be performed to identify the root cause of failure. The information presented in the root cause F/A will allow the product designer, manager, test and process engineers, or end-user to identify design, selection, test, and process deficiencies. Recommendations for corrective actions from the failure analysis report can then be evaluated and implemented to enhance product reliability and performance. By having an unbiased F/A performed by an independent test laboratory, the liability of a failed device or material can be converted into an asset, resulting in production of higher quality products.

  • High Speed DC Electronic Load

    6330A series - Chroma ATE Inc.

    The 6330A family offers 8 types of modular loads with power ranging from 30 watts to 1200 watts, current from 0.5mA to 240A, and voltage measurement from 0.5mV to 500V. Each load is isolated and floating, programmable in dual current range and measuring voltage range, and capable of synchronizing with other modules for control operating. The load can be operated in constant current, constant voltage, and constant resistance. With Synchronic parallel control capability, 6330A series loads allow users to parallel and synchronize more than one load together from an internal loading control signal. This feature provides synchronic dynamic loading test for multi-output power and high power test solution. Real time measurement of voltage, current, is integrated into each 6330A load module using a 16-bit precision measurement circuit. The user can perform on line voltage measurement and adjustment, or simulate short circuit test using the simple keypad on the front panel.

  • Microwave Frequency Counter (up to 40GHz)

    S4382 - Saluki Technology Inc.

    Saluki S4382 series microwave frequency counter adopts microwave sampling technology to realize microwave measurement. The function control, measurement sequence and data processing of the whole measurement process are completed by the internal microprocessor. It is a new generation of intelligent microwave frequency measurement instrument. The instrument adopts medium and large scale integrated circuits and some monolithic integrated circuits with excellent performance, which makes the design of the instrument more reasonable, with low power consumption and high reliability.

  • 10KV Insulation Resistance Testers

    DIT-915: - Neutronics Manufacturing Co.

    • A timer which shows the elapsed time when the test was "ON" and also shows the total time of the test• Displays a voltage warning and sound when AC or DC is present before injecting the test voltage.• A buzz will intermittently sound when high voltage is generated and continues until the circuit is fully discharged• Four voltages (1KV, 2.5KV, 5KV and 10KV)• Auto-ranging and menu-driven.• A bar-graph which displays the voltage decay during the discharge of the tested circuit and the voltage stressing the insulation while the test is in progress

  • 4.0 GHz, 0.6 pF, 1 MOhm Active Voltage Probe

    ZS4000 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.6 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.

  • 2.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe

    ZS2500 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS2500 is ideal for 2.5 GHz and lower oscilloscopes.

  • 1.5 GHz, 1 MΩ, 0.9 pF Active Probe

    ZS1500 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1500 is ideal for 1 GHz and lower oscilloscopes.

  • 1 GHz, 1 MΩ, 0.9 pF Active Probe

    ZS1000 - Teledyne LeCroy

    Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1000 is ideal for 200–600 MHz oscilloscopes.

  • Essential Instruments

    Digilent Inc.

    All Digilent test and measurement devices are multi-instrument electronics tools designed to bring the benchtop to you. Digilent's portable USB scopes, logic analyzers and signal generators allow you to measure, visualize, generate, record, and control mixed-signal circuits of all kinds. Combined with our free WaveForms software, detailed documentation, and a dedicated support community, our test and measurement hardware will turn your computer into a multi-instrument circuit analysis tool, all without the physical constraints of a lab.

  • Insulation & Multifunction Tester (OLED Display)

    1154 TMF-M - Standard Electric Works Co., Ltd

    ● High Contrast OLED display.● Designed for viewing in the dark, for mining industry.● Auto-range microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto-discharge on all tests and all ranges.● Leads auto-null key.● Test auto-stop.● Smart hold and stop on voltmeter AC/DC.● Ener-Save.● Continuity short circuit >220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● BS 16 edition.

  • Digital (1kV below) Insulation Tester

    2751 IN - Standard Electric Works Co., Ltd

    ● Timer for test function (count 3-5 minutes).● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338”) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● Data hold function● Auto power off function.● BS 16 edition.

  • Power Limiters

    Keysight Technologies

    Keysight's power limiters provide the best broadband input protection from excess RF power, DC transients and ESD, for a variety of RF and microwave instruments and components. For example, the input circuitry of spectrum analyzers, network analyzers, frequency counters or amplifiers can be protected from unintentional inputs up to 5 watts average power. At even greater power levels, failure mode for the limiter is either an open circuit or a short circuit to ground, thereby protecting the instrument from damage.

  • DC Measurements

    Daqarta

    Standard Windows sound cards do not respond to DC or frequencies lower than a few Hz. (See Why Sound Cards Block DC Signals below for explanation.)There are two general approaches to get true DC response from a standard sound card: Modify the card, or add an external circuit to convert the DC into an AC signal which can be easily measured by an unmodified card.

  • Gaussmeter

    DX-103 - Dexing Magnet Tech. Co., Ltd

    DX-103 Gaussmeter is a desktop gaussmeter.Which is based on he latest progress of the the Hall Effect magnetic field measuring instrument.Adapt the high stability constant current source circuit technology to design and manufacture. Test probes adapt imported GaAs linear Hall-chip, the difference between probes is small, which can be replaced directly when it is damaged, and is an ideal AC & DC magnetic field test instrument.