  • PXI Dual 32x4 Matrix 1-Pole Screened

    40-534A-021-S - Pickering Interfaces Ltd.

    Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.

  • PXI Dual 32x4 Matrix 2-Pole Switching

    40-534A-022 - Pickering Interfaces Ltd.

    Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.

  • Non-contact Ultra-High Range Sheet Resistance Measurement System

    CRN-100 - NAPSON Corp.

    *Ultra-High range sheet resistance measurement for 10E+9 ~ 10E+15 ohm/sq without contacting*Mapping program software;*1. Arranged in a multipoint pattern measurement is programmed*2. 2-D & 3-D mapping software*Easy operation by Windows 7 system software*Measurement data base link with Excel via CSV format file*Unaffected by contact resistance

  • Resistivity and Hall Effect

    Cryogenic Ltd.

    The Resistivity System allows the user to make Resistivity and Hall Effect measurements in the range of to M. Samples are mounted on special platforms inside the VTI with contacts made to the sample according to the customer's requirements. Connections at the top of the probe are made via Fischer Connectors or Coaxial Cables. Keithley source and measurement electronics are provided with the system. These are fully controlled using the Measurement System Software.

  • Wristat Tester

    WT25 - Walter G. Legge Company Inc.

    The WT25 WRISTAT Tester is designed to test the integrity of our WRISTAT in a fast, efficient and simple manner. All of the elements of the WRISTAT - continuity of the strap, integrity of the protective resistor, and satisfactory strap to skin contact are easily confirmed by pressing the top cover of the WT25. The operator (wearer) is tested for a resistance to ground of greater than 750K ohms and less than 10M (switchable to 100M ohms).

  • Standalone Bench Test System for FCT, ICT, ISP and Boundary Scan

    LEON Bench - Konrad Technologies GmbH

    The LEONBench test system is a flexible and scalable test system that features an excellent signal integrity and a high-quality fixture interface. This is achieved by combining a cableless connection from ABex modules to Virginia panel interface connectors. The system is optimized for high pin count test applications. Furthermore, it can be equipped with vacuum and pneumatic. Support for multi-level contact fixtures enables separate contact levels for FCT and ICT. The Konrad ITA (Interchangeable Test Adapter) frame allows various fixture houses all over the world to build custom fixtures for the LEONBench. Up to 15U additional rack space allows adding a bunch of high-performance measurement devices from various manufactures. An integrated power distribution unit takes care about power on and off sequencing.As part of the LEON Family, LEONBench is based on the ABex platform which directly incorporates Konrad analog bus technology and PXI/PXIe in one chassis.

  • Controllers

    BKM93KIO - Techna-Tool Inc.

    Clockwise and/or counter-clockwise rotation of the wand is programmable allowing an optimum adaptation to the machine.The scanning intensity is adjustable in 8 steps. Even rotating drills with small diameters can be checked.The scanning results are display as "OK" or "KO" and signalled by LEDs on the front side of the device.The PROFIBUS is a standard Sub-D 9 pin connection; the USB connection is a USB-mini plug / type B and meets the 2.0 specification.Three digital inputs serve to activate the functions "Teach-in" to learn the position to be scanned, "Start" to initialize the scanning process and "Configurable" for receiving a stop command.Two digital outputs provide the signals for the message "OK" or "KO".The relay contacts are configurable as N/C or N/O connections. They can be set as momentary (valid with start or timed) or latching.Convenient configuration software for programming and setting of tool data is available at no cost.

  • Signal Conditioners

    General Purpose - Encore Electronics, Inc.

    Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.

  • Battery Impedance Meter

    Alpha Lab, Inc.

    Operation is fast and simple. Just press the spring-loaded probes onto the two poles of the battery. After 1.5 seconds, the unit beeps (indicating good contact) and displays the battery voltage and either the number of siemens or milliohms, depending on the knob setting. The display continues to show these numbers after the probes are removed; it resets only when the probes are pressed onto the next battery. The impedance and voltage of any battery between 1.2 and 60 volts can be read. Because of the wide range of voltages, even single low-voltage cells, such as NiMH, can be measured. The manufacturers of some batteries specify impedance in milliohms while other specify in siemens (one divided by the resistance in ohms). This meter will display both types of impedance for any given battery. Accuracy is +/- 2% of the value.

  • Power Amplifiers for Radio Amateurs

    Kuhne electronic GmbH

    From classic equipment for simple QSOs to high performance modules for contests, EME-operations and satellite radio: Our products provide absolute top performance. When choosing their equipment many radio amateurs and club-stations don't compromise and trust in the proven quality of Kuhne electronic amplifiers. Numerous contest victories, records and first contacts with a country were and are achieved with Kuhne products. Our amplifiers are remarkable for high gain and high linearity. LD-MOSFET and GaAs-FET-systems are the state-of-the-art technology in the amateur sector and enable the perfect use for all analog and digital modes (e.g. SSB, CW, WSJT, ATV, DATV). Small mechanical measurements and milled aluminum cases enable high temperature stability and tower mounting. Don't compromise and get technology from Kuhne electronic!

  • Milliohm Meter

    16502 - Chroma Systems Solutions, Inc.

    Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface

  • SSMA Connectors

    Pasternack Enterprises, Inc.

    Pasternack SSMA connector category includes 52 part numbers, most are RoHS and REACH compliant. SSMA connector series in this category will terminate to coax, PCB (printed circuit board) or terminal. Pasternack SSMA connectors are built to precise microwave and RF industry specifications. Connectors in SSMA series are manufactured in male or female gender with 50 Ohm impedance. SSMA connector items are available in straight or right angle versions, as well as, bulkhead, 2 hole panel, 4 hole panel or mountless options. These SSMA connector designs include crimp/solder, solder, solder (without contact) or solder/solder attachment methods. Like the other over 40,000 RF, microwave and millimeter wave products from Pasternack, this SSMA connector series is in-stock. Not just in stock, but these connectors will ship the same day as they are purchased.

  • Programmable Step Attenuator, DC to 4 GHz, 0 to 11 dB, 1 dB steps

    8494G - Keysight Technologies

    The Keysight 8494G dc to 4 GHz programmable step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 1 dB steps from 0 to 11 dB. Precision gold-plated leaf springs ensure long-life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option UK6. A maximum switching time of 20 ms (including contact settling) speeds automatic testing. Custom step attenuator/switch combinations are possible. The Keysight 11716A/B/C interconnect kits provide quick connection of Keysight 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.

  • PXI Single 55x8 Matrix 1-Pole Switching

    40-538-021 - Pickering Interfaces Ltd.

    The 40-538 ultra high density matrix module is configured as a Single 55x8 reed relay matrix with 1-pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering >10e8 operations to give maximum switching confidence with long life and stable contact resistance.

  • PM&C Services

    Testing Machines, Inc.

    TMI has a wealth of knowledge in instrumentation covering a variety of industries. Our Global PM&C (Preventative Maintenance and Calibration) Group is capable of providing calibration services for most laboratory instruments including Tensile Strength, Thickness, Elmendorf Tear, COF (Coefficient of Friction), Smoothness, Porosity, Parker Print Surf, Contact Angle, Compression, Burst Strength, Melt Flow, Impact Strength (IZOD/Charpy).