Showing results: 811 - 825 of 6936 items found.
-
WDC -
Seismic Source Co.
The WDC unit consists of the following: *Weight Drop Relay Control System *Radio Trigger Module (RTM) *Remote Control Box *Radio*Hammer Switch The WDC provides following features: *Automatic cycling with user entered number of hits*Time Delay Display (Time from fire command to hit)*GPS interface for position and timing*Remote Control Box
-
Macintyre Electronic Design Associa
he MEDA turnkey closed loop magnetic field sources cancel the local ambient field as well as generate accurate and uniform magnetic fields in a control volume. The sources use Helmholtz coils driven by control currents to produce stable magnetic fields from 1 nT to 100,000 nT. The accuracy of the field in the control volume is better than 0.05% of the setting.
-
CXAR/128-MF -
Cytec Corp.
These Chassis controls up to sixteen 8x1 modules, thirty two 4x1 modules or any combination or configuration of 8x1's, 4x1's, 2x1's and 2x2 modules. LEDs on the front panel show switch and power status. Add Switch Modules, CP8 Driver Modules and a Control Module to complete the system. Keypad Manual manual control with LCD display is optional.
-
Alicat Scientific, Incorporated
use Coriolis or laminar flow technology to accurately control liquid flows across a wide range of applications. Coriolis flow controllers can accurately control liquid flow rates up to 100 kg/h, including for aggressive liquids and unknown compositions. For water and other non-corrosive liquids, our laminar liquid flow controllers provide real-time control of process flow and pressure.
-
DeFelsko Corp.
Coating thickness or dry film thickness (DFT) is an important variable that plays a role in product quality, process control, and cost control. Measurement of film thickness can be accomplished by selecting the best mil gage for the particular application.
-
Sharp Shooter II -
Bounty Hunter
Microprocessor-Controlled ElectronicsTouch pad selection control panel4 Modes of operationAutomatic ground balance3-Tone Audio DiscriminationMotion Discrimination systemNo-Motion All Metal ModeAuto Notch & Variable Notch control system8" Concentric, open-face waterproof searchcoil
-
8004 -
April Instrument
5 digit BCD, 1 latch control line, 25 pin female, D type connector. 5 digit BCD, 1 latch control line, 25 pin female, D type connector
-
FS-3000 -
HORIBA, Ltd.
FS-3000 combines HORIBA STEC’s mass flow controller (MFC) and MuCube (Master controller). By controlling MFC from MuCube equipped with the HORIBA STEC’s proprietary control algorithm, FS-3000 achieves stable splitting control.
-
SKZ101 -
SKZ Industrial Co., Ltd
Its precise auto control and data acquisition system allow it to automatically acquire data and control the procedures. It can measure tensile strength, elongation, deformation, equipped with printer, the test results can be printed. And also equipped with the extensometer.
-
Holding Informtest
Informtest QtRegistrator is software for creating telemetric information and control systems. Informtest QtRegistrator allows you to create and deploy multichannel measurement and control systems using modern developments of measuring equipment standards VXI, LXI.
-
ComEth4590a -
ELMA Electronic, Inc.
The ComEth 4590a is a high-performance layer 3 switch with2 Ethernet switch matrices to control and physically separate the Control and Data Planes for highly secure network communications. In 10GbE and 40GbE Ethernet copper and fiber configurations.
-
ElectroStatics, Inc.
Ionization or anti static blowers are the most versatile ionizer to control or remove static electricity from plastic, paper, glass and other non conductive materials. This static control blower offers the ability to cover a large area cost effectively. This static control equipment is an excellent choice to reduce static electricity and reduce operator static shocks and production applications needing large area coverage.
-
Nippen Electrical Instruments Co.
NIPPEN Maximum Demand Controller offer demand monitoring with date and time of occurrence. The present and predictive demand are displayed separately. The Maximum Demand Controller (MDC) has 4 relays to facilitate tripping of non essential loads.The trip setting is done according to the contract demand offered by the Electricity Board. Demand control is done by 1) Step Demand Control 2) Forecast Demand Control
-
Ametek Scientific Instruments
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
PCI-8144 -
ADLINK Technology Inc.
The ADLINK PCI-8144 is a pulse train motion controller ideal for stepper motor control. This controller provides T/S curve control, on-the-fly speed change, non-symmetric acceleration and deceleration profile control, and simultaneous start/stop functions. This controller also offers card index settings for multiple cards in one IPC system and a hardware security function to prevent unauthorized use of in-house developed applications.