  • Portable Digital Manometer

    PS309 - Validyne Engineering

    Featured are an integral variable reluctance transducer, solid state electronics module, 3 digit liquid crystal display (LCD)* and battery pack with six 1.5V penlight cells for truly portable operation. The units can also be powered from an external DC power supply or AC battery eliminator (converter) module. The transducer features all corrosion resistant materials in contact with the pressure media (both ports in differential units), very low internal cavity volumes and ultra-low volumetric displacement with full-scale pressure excursion. Transducer calibration is unaffected by dielectric properties of the sensed fluid. Gauge and differential transducers may be disassembled and range changed by simple diaphragm replacement.

  • Non-Contact Resistance Online Tester

    MEWOI Electronics Co.,ltd

    Non-Contact Resistance Online Tester is our company devotes ourselves to Grounding resistance test technical research’s another new high-tech product for more than ten years. Detector adopts weather fastness material manufacture, temperature resistance, cold-resistant, corrosion prevention, fire prevention. Detector’s structure is rigorous and firm, against rain, dustproof, installation and use outdoors. Non-contact measurement, safe and reliable, Ease of installation. Grounding down lead is directly through the detector perforation, Will not affect lightning protection grounding effect and the normal operation of the facilities. Ensure high-accuracy, high stability and high reliability of long time on-line monitoring outdoors, underground mine and indoors.

  • Clora Online

    XOS

    Chlorine is often present in crude oils and the concentration can vary greatly depending on the origin. If not removed, Chlorine can react to form highly corrosive hydrochloric acid in areas such as crude tower overheads, leading to serious operational issues, economic loss and safety concerns. The need for a reliable online chlorine analyzer for refining process control is more important than ever. Clora Online complies with ASTM D7536 method, and delivers continuous chlorine analysis to monitor plant equipment corrosion. By monitoring desalted crude, a plant can optimize performance and immediately see impacts of crude changes (including organic chloride). Additionally, monitoring overhead water can provide the necessary feedback for chemical feed.

  • Materials And Chemical Analysis

    Anderson Materials Evaluation, Inc.

    Materials characterization, failure analysis, quality control, and materials and process development services are offered.  Our analytical techniques allow us to assess elemental and chemical material composition, thermal properties, coating thickness, electrochemical properties, surface chemistry, surface wetting, corrosion rates and pitting potentials, contamination and degradation problems, metallography, fractography, phase transitions, static coefficient of friction, adhesive bonding strength and causes of adhesive bonding failures, surface tension and surface energy, tensile and compressive strength, bend deflection, lapshear strength, elasticity properties, UV and visible light absorption and reflection, density and porosity, and many other material properties integral to improving your products.

  • Digital Tank Test Kit

    4109 - M. C. Miller Company

    The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `

  • Roughness Testers

    PCE Instruments

    Roughness is an important parameter when trying to find out whether a surface is suitable for a certain purpose. Rough surfaces often wear out more quickly than smoother surfaces. Rougher surfaces are normally more vulnerable to corrosion and cracks, but they can also aid in adhesion. A roughness tester is used to quickly and accurately determine the surface texture or surface roughness of a material. A roughness tester shows the measured roughness depth (Rz) as well as the mean roughness value (Ra) in micrometers or microns (µm). Measuring the roughness of a surface involves applying a roughness filter. Different international standards and surface texture or surface finish specifications recommend the use of different roughness filters. For example, a Gaussian filter often is recommended in ISO standards.

  • Analog Tank Test Kit

    4108 - M. C. Miller Company

    The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.

  • Dissolved Ammonia Delivery System

    DI-NH3 - MKS Instruments

    MKS' DI-NH3 is a compact, stand-alone system providing dissolved ammonia water. With Semiconductor 3D IC architectures using new materials like Cu-Co and Si-SiGe, the ability to wet clean with precise alkaline chemistries is growing in frequency and importance. The DI-NH3 delivers dissolved ammonia, providing optimal cleaning capability in an alkaline chemistry, minimizing material loss and contamination and inhibiting Electrostatic Discharge (ESD). Using closed-loop control, conductivity and pressure are kept stable under changing flow conditions. The dissolved ammonia concentration is monitored and adjusted, delivering the specific NH4OH concentration needed. Dissolved ammonia’s alkaline chemistry provides ESD protection during rinsing, particle lift-off, and residual photoresist removal in middle-of-line (MOL) and prevents corrosion of cobalt/copper interfaces.

  • High-Temperature and High-PressurepH Electrodes

    UltraDeg - Corr Instruments, llc

    Corr Instruments offers a full range of exceptionally high performance, high-temperature and/or high-pressure UltraDeg probes, including pH electrodes, reference electrodes, platinum conductivity probes, and ORP(redox) electrodes, for temperatures up to 650F (343C) and pressures up to 5100 psi (35 MPa). These probes are ideal tools for corrosion monitoring, thermodynamic or electrochemical studies in harsh environments such as steam generators, nuclear power reactors, geothermal systems, deep oil/gas wells, and super critical water systems. Many of these UltraDeg probes are built upon our innovative sealing compound, Queon, which is the only known material in the world for sealing electrical conductors in metal sealing glands or compression feedthroughs that are operable at temperatures between 400F (200C) and 650F (343C).

  • Analytical Techniques

    Anderson Materials Evaluation, Inc.

    Our numerous analytical techniques, we tackle a wide range of materials challenges and commonly combines several analytical techniques to fully address complex and multi-dimensional materials issues.  Our materials analysis laboratory provides XPS surface analysis, thermal analysis (TGA, DSC, TMA), FTIR infrared spectroscopy, UV-Vis spectrophotometry and reflectivity measurements, gas chromatography – mass spectroscopy (GC-MS), SEM/EDX, optical microscopy, mechanical testing, electrochemistry and corrosion analyses, residual gas mass spectroscopy, contact angle measurements, surface contamination measurements, adhesive bonding failure analysis, facility testing for silicone contamination, mechanical testing, metallography and fractography, density and porosity measurements, volatile organic component testing, friction, and other analytical capabilities.  We continue to upgrade and expand our arsenal of analytical techniques and custom analytical methods to support our customers’ needs.

  • Level System

    Universal II - AMETEK Drexelbrook

    The Universal II level transmitter offers increased reliability, low maintenance and an intrinsically safe design for dependable level measurements in all kinds of process liquids, slurries, granulars and interfaces.Universal IIThe Universal II is a two wire level transmitter that eliminates the need for line power in the field and saves costs for additional hardware. It provides reliable level measurements in all kinds of process liquids, slurries, granulars and interfaces.When powered from an approved source this level transmitter can be made intrinsically safe. Its rugged contruction resists corrosion and abraision. The no moving parts design eliminates break downs.The Universal II level transmitter utilizes RF Admittance technology with manual calibration and a 4 – 20 mA output signal. The patented Cote-Shield circuitry ensures accuracy and reliability regardless of product build-up on the level transmitter.This level system is unaffected by changes in the process material density, pressure, or temperature variations.

  • Harness Design and Manufacture

    Teledyne Marine Impulse-PDM

    When designing an underwater cable harness, there are some factors which need to be considered, and we have produced the following list as a guide for customer information:Component considerations:- Electrical requirements- Mechanical considerations- Quality requirements- Reliability- Design redundancy (contact count)- Connector selection (type and form)- Locking requirements- Backpotting requirements- Waterblocking in moldings- Cable specification- Cable jacket material and compatibility with elastomers- Abrasion resistance- Stiffness profile at termination- Connector format (straight or right angle)- Molding format (straight or at an angle)- Clearance allowance for molding and cable routing- Elastomer compatibility (eg oil filled units)- Metalwork selection re: corrosion and cathodic delamination- Surface finish for metalwork as appropriateOperational considerations:- Operating depth profile (not just max. depth)- Tensile loads- Torsional loads- Bending loads- Bend control requirements (to limit bending at termination)- Deployment and recovery loads- Dynamic loading-Flow turbulence effects.

  • Connector Board for Cable and Harness Tester

    CB49 - CAMI Research Inc. (CableEye®)

    Populated with solder pads to accept a suite of TE-Connectivity Micro-MaTch connectors, this board addresses markets plagued by vibration and fretting corrosion, and requiring "miniaturized connectivity". Rated to 500Vdc/350Vac, the CB49 may be used on all CableEye models. The CB49, sold without connectors, contains nine sets of 20 solder pads accommodating numerous configurations of Micro-MaTch connectors. There are nine preset locations for automatic detection & display of 4, 6, 8, 10, 12, 14, 16, 18, and 20-pin connectors. Yet, any single set may be fitted with any combination of lower pin count connectors that total to 20 or less (e.g. a 14-pin with a 4-pin). Connectors soldered in non-preset positions will also appear graphically correct once they are mapped with PinMap (optional software). Sold as a set of two boards, each Micro-MaTch test board may be paired with other CableEye adapter boards to accommodate any combination of connectors.

  • pH & ORP Sensors

    Barben Analytical

    The Barben Analytical Performance Series products are 3rd generation combination pH/ORP electrodes targeted at harsh, industrial measurement applications. High pressures, strong chemicals, and elevated temperatures typically shorten the lifespan of conventional double-junction pH probes. In these applications the Performance Series sensor offers extended sensor lifespan, as well as decreased drift, and longer calibration intervals. Each sensor is manufactured with our patented Axial Ion Path® reference technology, proprietary Low-Noise & High-Temp Signal Cable along with proprietary ruggedized, high temp and coat resistant glass formulations. A wide selection of sensor body styles and process fittings in a variety of corrosion resistant materials allow direct replacement of short-lived OEM pH/ORP sensors. Barben Performance Series sensors are compatible with all major manufacturers of pH analyzers and transmitters. Upgrade your analytical measurement without the hassle and expense of replacing costly field instruments.

  • Toxic Gas Sensor

    Model 100 - Teledyne Gas & Flame Detection

    Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.