Filter Results By:

Products

Applications

Manufacturers

Current Meters

Measure current using either "Average responding" meters reading linear loads or "True RMS" meters measuring non linear loads.


Showing results: 331 - 345 of 498 items found.

  • Multi-Meter

    Talon-Curve - Talon Meters

    A portable instrument that enables you to troubleshoot electronic equipment in a powered down state. Simply place the leads across a component and the meter will display a graph allowing you to identify the type and range of each component tested. A helpful capture feature allows you to quickly compare the current component in test to a like component that was previously tested.

  • Primary Cable Fault Locating

    Directional Impulse Detector - Timco Instruments, LLC

    The Directional Impulse Detector ( D.I.D.) is a compact handheld detector used to locate primary cable faults by sensing the magnetic field generated by the current pulse from a high voltage discharge device (thumper). A meter deflection indicates the intensity of the received signal. No deflection indicates that you have walked beyond the fault or away from the cable.

  • Fully Automatic Non-contact Sheet Resistance Measurement System For Flatpanel Display

    NC-60F/RS-1300N - NAPSON Corp.

    *Global standard for non-contact measurement of ITO film, Metal thin films on flat panel*Automatic X-Y and Z (eddy current probe head) axis moving mechanism*Compatible with Loading robot for fully automatic measurementOption :*Integlate to combined system (film thickness meter, etc)*Add 4 point probe measurement unit : RT-3000

  • AC Power Measurement and Logging

    WattNode® Logger for LonWorks® - Continental Control Systems LLC

    The WattNode Logger is a kilowatt hour (kWh) energy meter that communicates on a LonWorks network, and can log 24,000+ measurement records in non-volatile memory. The WattNode Logger measures 1, 2, or 3 phases with voltages from 120 to 600 volts alternating current (Vac) and 5 to 6,000 amps in delta (phase to phase) and wye (phase to neutral) configurations.

  • Electrometer / High Resistance Meter, 0.01fA, Battery

    B2987B - Keysight Technologies

    The B2987B Electrometer/High Resistance Meter is the world’s only graphical electrometer that allows you to confidently measure small currents with 0.01 fA (0.01 x 10-15 A) resolution and large resistances of up to 10 PΩ (10 x 1015 Ω). In addition, battery operation eliminates AC line noise from your critical measurements.

  • Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit

    72-7770 CAL - Tenma

    The 72-7770 CAL from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.

  • Calometric Power Meter

    M1-25M/XXE - Elmika

    The M1-25M/XXE series instruments are high precision broadband Calorimetric Sensors operating in millimeter and sub-millimeter wave range on a principle of substitution of microwave power by direct current power, using an autocompensating transistor transducer. Calorimetric Sensor is supplied with Calorimetric Power Meter M1-25M (measurement and indicator block), which provides PC connection via USB interface.Calorimetric Power Meter with Calorimetric Sensor provides accurate absolute power measurements in single mode and multimode waveguides (Metal Dielectric Waveguide) which could be a priority for terahertz physics and technology.

  • Static Measurement

    Nex Flow Air Products Corp.

    electrofield meter is a small hand-held field strength meter with a digital display for measuring electrostatic charges in Volts. It perfectly combines easy operation with an accurate measuring technique. The Static Meter measures charges according to the field influence principle C: The influenced charges, caused by the electrical field, generate an alternating current proportional to the electrical field strength. The selective amplifier converts this value into the corresponding field strength or electrical potential – without withdrawing energy from the electric field over the averaged time.

  • Microohmmeter

    MMR-6500 - Sonel S.A.

    The MMR-6500 digital meter is designed for measuring low resistances with a stabilised current of up to 100 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6500 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.

  • Microohmmeter

    MMR-6700 - Sonel S.A.

    The MMR-6700 digital meter is designed for measuring low resistances with a stabilised current of up to 200 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6700 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.

  • 500 AMP Carbon Pile Load Tester

    710 - Electronic Specialties Inc.

    The #710 will perform variable load testing on 12 volt batteries rated as high as 1000 Cold Cranking Amps. Use this battery tester to simulate actual cranking loads. Also tests alternator charging voltage and relative starter current draw. The #710 features large dual meters to display the battery voltage and load current simultaneously, during the test.

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • Ampere Hour Meter Module

    TE2504 - Ajinkya Electronic Systems

    Ampere Hour Meter Module- Model TE 2504 is basically managed for ready setup or the usage can be seen in where the current requirement are low. This one is used which is ready to be applied in the stand alone panel and advanced from all the former models, IM2501, IM2502 and IM2503. These are basically panel mount instruments which are required to rectified in the rectifier or in an independent panel.

  • Auto-Ranging Digital Clamp Meter

    DCM401 - Draper Tools Ltd

    Expert Quality, auto and manual ranging clamp meter capable of voltage, current, resistance, diode, continuity, capacitance, frequency, duty cycle and temperature testing. Maximum jaw - opening diameter of 36mm, backlit LCD screen, auto power off and a useful inspection light. Supplied with test leads, temp probe, case and 3 x AAA batteries.

  • sbRIO-9227, Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module

    781118-01 - NI

    Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The sbRIO‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a C Series Voltage Input Module, the sbRIO‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics. Non-enclosed modules are designed for OEM applications.

Get Help