Filter Results By:

Products

Applications

Manufacturers

Current Meters

Measure current using either "Average responding" meters reading linear loads or "True RMS" meters measuring non linear loads.


Showing results: 496 - 498 of 498 items found.

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TD Series - IBEKO Power AB

    Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options

  • Single-Phase Transformer Winding Resistance Meters

    RMO-TT Series - IBEKO Power AB

    RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.

Get Help