Showing results: 1021 - 1035 of 2606 items found.
-
TP-S 1500W Series -
Twintex Electronics Co., Ltd
The TP-S series are high power output DC power supply with output range up to 6kW. The TP-S series can be made according to customer request, with output voltage up to 800V and output current up to 200A.
-
TP-S 6000W Series -
Twintex Electronics Co., Ltd
The TP-S series are high power output DC power supply with output range up to 6kW. The TP-S series can be made according to customer request, with output voltage up to 800V and output current up to 200A.
-
Testboy GmbH
The non-contact voltage tester detects live conductors on cable connections, cable drums, sockets, switches, junction boxes etc. Due to capacitive measurement procedures, no current flow is required and interruptions can be indicated quickly and accurately.
-
M-2100 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Wide current measurements with tear drop type 55mmφCT up to 2000A.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Conform to IEC safety requirements.
-
DBT-12+ -
DeltaTech Electronics
The tester enables safe measurement of voltage, current rating, state of charge and state of health for 12V and 6V batteries. The device is powered by an internal battery, so it can test even discharged batteries and can be conveniently used as a voltmeter.
-
700 -
Electronic Specialties Inc.
The #700 has an internal loading capacity of 100 amps. It is a great tool for finding batteries that can’t stand up to the load of today’s automotive accessories. It will also test relative starter current draw and charging voltage.
-
DA3 -
North Atlantic Industries
The DA3 module features 4 high-current D/A output channels with a full-scale range of ±40 VDC or ±100 mA (max). The DA3 provides either voltage or current control loop modes that are programmable for the particular application.
-
NI
Digital Multimeters measure voltage, resistance, current, capacitance, inductance, and temperature. Some models also have an isolated digitizer mode. Use these products to test consumer electronics, fuel cells, aerospace production, and more.
-
MPI-502 -
Sonel S.A.
Short circuit loop parameters measurements:measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, *230 V/400 V, 240/415 V and frequency 45...65 Hz,*measurements of short circuit loop impedance with current 15 mA without tripping the circuit breaker.Testing the RCD breakers of AC, A types:*testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,*IA measurement*RE and UB measurement without tripping the circuit breaker,*extended RCD test function AUTO, with measurement of ZL-PE with current 15 mA - measurement of IA and tA during one RCD tripping.Detection of the replacement L and N in the socket and automatic conversion in the meter.Low voltage resistance measurements of protective circuits and junctions:*measurement of resistance with ±200 mA current*calibration of test leads - possibility of using any length of test leads,*low current resistance measurement with accoustic signalling
-
Carl E. Holmes Company
- 12 Pulse SCR Controlled Power Supply, P/N 19435PS- Input: 480 VAC, 300 Amps, 3 PH, 60 Hz- Output: 0 to 3000 VDC ± 10%, 80 Amps max adjustable with potentiometers, and 4/20 mA input signals from the PLC- Output voltage and current are provided as 4/20 mA signals to PLC- Contactor and overload relay are installed for protection- Power ON Light- Start / Stop capability- EPO capability- Manual voltage control and current limit- PLC interface- Output voltage and current are displayed on the voltmeter and ammeter.- A selector switch is used to select between manual Control or PLC Control- The customer is responsible for the PLC controller and PLC programming- Power enclosure, 68″H x 65″W x 44″D- Control enclosure: 20″H x 16″W x 9″D- Weight: 5000 lbs. approximately- All input/output connections are inside the enclosure
-
Osborne Transformer Corp.
Osborne has developed a wide range of DC load simulation inductors that are known for the transients they produce. Osborne DC load simulation inductors are unique and innovative because they are engineered to produce a precise time constant current transient during the current charge cycle.Another distinguishing feature of our load simulation inductors is that they produce a precise voltage transient during the current discharge cycle. The resulting test circuit can be used to accurately replace real loads in a variety of circuit simulation applications.
-
Analog Devices Inc.
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
CTS Series -
Continental Control Systems LLC
The CTS series CTs are available with windows from 0.75 inch up to 2.0 inch. They have a removable section, so that they can be installed without interrupting the circuit. 0.333 Vac output at rated current Accuracy ±1% from 10% to 100% of rated current Phase angle <2° degrees at 50% of rated current (valid for 70 A or higher) 8 ft. twisted-pair wire, 600 Vac rated UL recognized for voltages up to 600 Vac, CE mark, RoHS
-
KT7193 -
Ketai instrument (kunshan) Ltd.
● 3 3/4 digits 3999 count● Extra high DC/AC current measurement● Data hold to capture measurements● Backlit display is easy to read under any light condition● AC current measurement up to 1500A● DC current measurement up to 1500A● DC/AC voltage, resistance, capacitance, frequency and temperature measurement● Diode and continuity test● Accessories included: 9V battery, carrying case, test leads, K typetemperature probe, English manual, gift box
-
Analog Devices Inc.
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.