Filter Results By:

Products

Applications

Manufacturers

Showing results: 1996 - 2010 of 2641 items found.

  • NI-9485, 8-Channel, SSR Relay, 60 VDC/30 Vrms, 750 mA C Series Relay Output Module

    779600-02 - NI

    The NI-9485 allows for direct connection to a wide array of industrial devices such as motors, actuators, and DC devices. Each channel provides access to a solid state relay (SSR) for switching voltages up to 60 VDC/30 Vrms with switching current up to 750 mA per channel or up to 1.2 A on four channels. Each channel also features channel-to-channel isolation.

  • NI-9485 , 8-Channel, SSR Relay, 60 VDC/30 Vrms, 750 mA C Series Relay Output Module

    779600-01 - NI

    The NI-9485 allows for direct connection to a wide array of industrial devices such as motors, actuators, and DC devices. Each channel provides access to a solid state relay (SSR) for switching voltages up to 60 VDC/30 Vrms with switching current up to 750 mA per channel or up to 1.2 A on four channels. Each channel also features channel-to-channel isolation.

  • Multi-Operational Surge Tester

    MB Model - PJ Electronics, Inc.

    Bench all-in-one versatile Multi-Operational Surge Tester that you need for all of your electrical insulation testing. The Hi-Pot tester has separate L.E.D. panel meters for direct readout (voltage and leakage current) so that no interpolation on the scopes display is ever needed. This MOST can surge test extremely low inductance windings, DC armatures, etc.

  • PXI SPST Power Relay: 20-ch, 5A, 300W

    M9135A - Keysight Technologies

    The M9135A is a general purpose switch with 20 independent, single-pole, single-throw (Form A) switches in a single PXI module. This module is ideal for switching heavy loads or power supplies including voltages mains or DC current. The heavy-duty armature relays are rated for up to 5A and 300W, enough for inductive or capacitive loads. Choose from the heavy-duty power connector or an unterminated power cable.

  • Load Module for SLSC

    Bloomy Controls, Inc.

    Bloomy's 8-Channel Load Module provides isolated current and voltage measurements for eight on-board 5W loads or for eight off-board 120W loads. With built-in switching for calibration and fault injection, the module provides unsurpassed capability for Mil/Aero applications. The module also provides switching and connections to allow switching between a real load (e.g., actuator, valve, etc.) and the simulated load.

  • 3-Phase Power & Harmonics Analyzer

    Extech PQ3350 - Extech Instruments Corporation

    Power measurements and analysis + datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case. Current Probes sold separately.

  • Digital Panel Meter

    Nippen Electrical Instruments Co.

    To be supplied with the right meter, simply furnish the following details in your order: Model Number, Description of the Meter. Accuracy Class. Voltage Input (110 Volts from PT, 240 Volts line to neutral or 415 Volts Line to Line). PT Ratio specifies the High Voltage Primary first ( 33 kV.110V). Current input (5Amps or 1 Amp secondary ) CT ratio (e.g. 100/5 Amps. etc.). Aux. Supply : 50/60 Hz (240VAC of 110/VAC). Dimension : 96 x 96mm or 48 x 96 mm or 144 x 144 mm.

  • Rail Traction Inverter Test System

    Electromechanica, Inc.

    The rail inverter test system uses a pulse test methodology to verify proper operation of the IGBT switching elements in a subway car motor control. The system is designed to verify proper commutation of the switching elements. A large capacitor bank allows testing at DC voltages up to 1kV and peak currents of up to 3kA into reactive loads.The system also integrates self test capabilities and safe-to-turn-on (STTO) diagnostics to ensure no gross faults are present prior to the application of high voltages. Further the system includes dielectric withstand (hi-pot) test capability to ensure electrical safety.

  • EIS Battery Analyzer

    BA8100 - B&K Precision Corporation

    The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.

  • Battery Discharge and Capacity Testers

    HD Power Test Equipment Co.ltd

    HDFD Battery Discharge Tester can be used as the discharge load in the battery off-line state to realize the constant discharge at the set value by regulating continuously the discharge current. When discharging, the tester will automatically stop discharging when the voltage on the battery group terminal or the cell falls to the set lower limit value, or when the set discharging time is out, or when it reaches the set discharging capacity. Battery Discharge Tester can records all valuable and continuous real-time data during the discharge process.This tester system is simple, safe and accurate for monitoring voltage of cells adopting wireless connection.

  • Digital Insulation Mult-Meter

    8010 IN - Standard Electric Works Co., Ltd

    ● Microprocessor controlled.● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V● The maximum insulation measurement range is 200G ohm @1000V.● 1mA test current on insulation test at nominal voltage.● With a hand strap for easier holding.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III 600V IEC 61557-1 IEC 61557-2 EN 61326-1

  • IVTS In-Vehicle Test Set

    LXinstruments GmbH

    The in-vehicle test set was developed to successively measure several active RF amplifiers installed in the vehicle as well as different antenna structures. It offers the possibility to connect 12 DUTs. The DUTs can be connected to an external spectrum analyser via a 1 to 12 RF multiplexer. Each DUT can be individually switched and supplied with an adjustable voltage via a bias-tee integrated in the system. The individual bias voltages and currents are recorded by the IVTS and can be called up on an interactive control panel or via Ethernet and SCPI commands. The complete system can be powered by rechargeable battery and can be operated either via Ethernet, fibre optics or WLAN.

  • Electronic Ballast Automatic Test Equipment

    ATE-1 - Lisun Electronics Inc.

    Test series connection, parallel connection and series/parallel connections of the electronic ballast (about 15 kinds of connections), available for various electronic ballast. • With a precise resistance box, tube is substituted for the resistance, can act as many as 6 tubes. Resistance value: 1-4095Ω adjustable. • Measure input parameters (vrms, irms, w, pf, harmonics, etc), output parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory frequency), can also test the ballast efficiency, abnormity protection, and power symmetry of partial rectifier effect and etc. • Program controlled AC power source to guarantee the smart choice of input voltage and the frequency. • Equipped with 17 inch LCD controlled machine, specially designed A/D combined with special CPU, has the two left and right testing interfaces to achieve stability of data and high- speed testing. • We can make the special-designed product for you and promise to upgrade the software for free.

  • Coupling Decoupling Network for Communication Lines

    CDN61000-5C - Lisun Electronics Inc.

    • Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP) • Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.) • Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode) • Input and output interface: RJ45 connector • Terminal layout (RJ45 connector): First pair of lines: pins 1/2 Second pair of lines: pins3/6 Third pair of lines: pins 4/5 Fourth pair of lines: pins 7/8 • Max. operating speed: 1000MBit/s • Max operating voltage: Max 50V DC • Max operating current: Max 1A Related Instruments

  • Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.

    72-2985 - Tenma

    The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.

Get Help