Showing results: 151 - 165 of 5323 items found.
-
100 / 101 -
Lake Shore Cryotronics, Inc.
The Models 100 and 101 are battery-powered DC current sources which provide a very stable output current without the noise commonly associated with AC line-powered instruments. They are well-suited for field maintenance and periodic monitoring of sensors, as well as operation in a highly noise-sensitive environment.
-
CTT -
ndb Technologies Inc.
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
CTS Series -
Continental Control Systems LLC
The CTS series CTs are available with windows from 0.75 inch up to 2.0 inch. They have a removable section, so that they can be installed without interrupting the circuit. 0.333 Vac output at rated current Accuracy ±1% from 10% to 100% of rated current Phase angle <2° degrees at 50% of rated current (valid for 70 A or higher) 8 ft. twisted-pair wire, 600 Vac rated UL recognized for voltages up to 600 Vac, CE mark, RoHS
-
TOS3200 -
Kikusui Electronics Corp.
The Leakage Current Tester TOS3200 is designed to perform leakage current (touch current and protective conductor current) tests on general electrical equipment but not medical electrical equipment.It enables you to conduct tests that conform to the requirements of the applicable IEC, UL, JIS, and other standards, as well as the Electrical Appliance and Material Safety Law. The memory in the main unit stores the 51 types of test conditions laid down in the IEC/JIS standards for information technology equipment, household electrical appliances, audio, video electronic apparatus, luminaires, motor-operated electric tools, and electrical equipment for measurement and control and in the Electrical Appliance and Material Safety Law, thereby enabling you to conduct standard tests with simple panel operation.
-
EE301-DCM-xx -
Executive Engineering
LCD Current Readings:0-80.0 / 40.0 / 20.0. LCD Voltage Readings:0-50.0 / 150.0
-
-
RCTi and RCTi 3ph -
Powertek LLC
The RCTi & RCTrms sensors convert ac current to an isolated 0-5V voltage or 4-20mA current loop. TA5V-5A allows compatibility with existing 1A or 5A CT metering circuits. Both offer a choice of proportional (rms) and instantaneous outputs. The available RCT current ranges are 0-100A to 0-50,000Apk. Both RCTi and RCTrms provide accurate measurement over a wide bandwidth ensuring precise measurement even with harmonically distorted wave shapes - using a flexible clip-on sensing coil. The RCTs are available as single and three phase models.
-
34330A -
Keysight Technologies
Measure current safely with this precision 0.001 ohm resistor housed in a plastic case surrounded by epoxy.
-
B-1002 -
Ruetz Technologies GmbH
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
B-1002 -
ROSS ENGINEERING CORPORATION
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
Qualitrol
The Iris Power MDSP3 uses the Current Signature Analysis technology which relies on the concept that faults in the induction motor rotor or driven components result in changes to the rotor magnetic field pattern. Unique magnetic rotating fields are produced due to the faults which induce detectable stator current components indicative of the fault.
-
RCT -
Power Electronic Measurments Ltd
The RCT range of AC current transducers are designed for permanent or semi-permanent installation and are available with industry standard outputs.
-
G. E. Motors (Pvt.) Ltd.
We are counted amongst the leading names in the industry, offering wide range of Field Current Regulator. Our entire product line ensures easy operations and is performance based. Field Current Regulator are quality tested and are delivered in standard configurations. Our entire product range has high strength and is delivered at most affordable rates.
-
-