Showing results: 1711 - 1725 of 5270 items found.
-
N5748A -
Keysight Technologies
The single output, 760W N5748A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
N5749A -
Keysight Technologies
The single output, 750W N5749A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
N5771A -
Keysight Technologies
The single output, 1500W N5771A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
QA Technology Company, Inc.
In-Circuit / Functional Probes, Socketless X Probes®, High Current Probes, Double Ended Probes, ATE Interface Probes, integraMate®
-
HG 200 -
Dr. Brockhaus Messtechnik GmbH & Co. KG
This process runs with constant flux alteration d/dt and avoids interference caused by eddy currents and phase displacement between the field strength and polarization measurements.
-
Milwaukee Electric Tool Corporation
A clamp meter is an electrical tester that combines a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.
-
Shenzhen Graigar Technology Co.,Ltd.
A clamp meter is an electrical tester that combines a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.
-
GPSL15 -
INSTOCK Wireless Components, Inc
GPSL15 is a two way, passive, GPS signal splitter ideal for splitting a GPS antenna signal between two receivers while providing a DC current path to power a remotely located active GPS antenna from one receiver while blocking the DC path from the other. Max voltage rating at the DC blocked port is 10 VDC; maximum current rating is 50 mA. Maximum voltage rating at the DC pass port is 50 VDC; max current rating is 1000 mA. Furnished with SMA female connectors all ports. Being a "micro-sized" splitter, GPSL10 weighs only 21 grams and is suitable for applications requiring low-weight parts.
-
Edmund Optics Inc.
Through the photovoltaic effect, detectors provide a means of transforming light energy to an electrical current. The root of the theory behind this phenomenon is a small energy gap between the valence and conduction bands of the detector. When light, with enough energy to excite an electron from the valence to the conduction band, is incident upon the detector, the resulting accumulation of charge leads to a flow of current in an external circuit. Since light is not the only source of energy that can excite an electron, detectors will have some amount of current that is not representative of incident light. For example, fluctuations in thermal energy can easily be mistaken for light intensity changes. A variety of these "non-light" contributions are present and, when summed up, make up the total noise within the detector.
-
CX-L19 -
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
UHPS -
RARA Electronics Corporation
*Max. current limit 707A*Excellent short term stability*Low temperature coefficient of resistance (T.C.R.)*High current sensing & reference resistors in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
CAEN S.p.A.
- From 12 to 48 independently controllable High Voltage channels- 0 ÷ 500 V output voltage (0 ÷ 250 V, A1519B and A1619 only)- Maximum Current 0.5, 1, 10 mA or 1 mA/100 μA (dual range boards)- Individual Enable (A151x only)- Either DB37, DB25, Radiall Multipin or SHV connectors- Available with either positive, negative or mixed polarity- Up to 20 nA, 100 pA current set / monitor resolution- Up to 10 mV / 1 mV voltage set / monitor resolution- Very Low ripple, down to < 5 mVpp- 3 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx) - Full Floating (A151x, A1612, A1619)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down - TRIP parameter- Current generator operation in overcurrent condition- Specific design for double side silicon detector (A151x)
-
FT6380 -
HIOKI E.E. Corp
The FT6380 measures grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A.
-
785659-03 -
NI
The TriaxM-TriaxM Triaxial Cable connects your system to PXI Source Measure Units and other devices that have a triaxial connector. It uses guarding to remove the effects of leakage current and parasitic capacitance when … measuring very low current signals. The cable offers 300 V DC maximum voltage, 3 A maximum continuous current, 10 A maximum pulsed current, and different lengths.
-
785659-01 -
NI
The TriaxM-TriaxM Triaxial Cable connects your system to PXI Source Measure Units and other devices that have a triaxial connector. It uses guarding to remove the effects of leakage current and parasitic capacitance when … measuring very low current signals. The cable offers 300 V DC maximum voltage, 3 A maximum continuous current, 10 A maximum pulsed current, and different lengths.