6450 -
The Eastern Specialty Company
The TESCO CT/PT Bus-Bar Safety Protector (Catalog No. 6450) has been developed to assist in the safe disconnect of a hot sequenced current transformer. After service is disconnected, the TESCO CT/PT Bus-Bar Safety Protector is slid over the bus-bar of the load side of the transformer and prevents accidental connection and/or arcing.
-
DB62X Series -
Danbridge a/s
The Danbridge Megohmmeter program is designed for fast measurement of leakage currents and insulation resistance (IR) of various components, cables, materials, etc. The fast and powerful measurement cycles, the high accuracy, and the broad measurement range make the Danbridge Megohmmeters to one of the most versatile insulation measurement instruments on the market today.
-
PM-10,PM-15 -
Standard Electric Works Co., Ltd
● Determine the running cost your appliances.● Make informed decisions when purchasing appliances and equipment.● Reduce your electricity bill.● Measure Voltage, Current, Power, Volts, Amps, Power Factor, and Greenhouse Gas Emissions.● Calculate electrical expenses by day, week, month, and even an entire year.
-
880 AT -
Standard Electric Works Co., Ltd
● The 880 AT is a simplified Version of an appliance tester which use low voltage and low current to perform it's checks.● Application Example The appliance is plugged into the mini appliance checker, then the probe make contact with the protective conductor.● Other appliance checking Washing Machine Toaster Iron Dish Washer Stove
-
SY 2100 -
Hong Kong Songyang Industrial Ltd.
Anthropomorphize design, Large size LCD display, easy operation. High stability, good reliability. Reasonable internal structure. Compliance with IEC736.ISO9001 certificate. Automatic switchover of voltage or current output to protect equipment when voltage circuit short or current circuit open and alarm display on LCD
-
TURNS-TTPT -
Vasavi Electronics
Digital TURNS TESTER for Counting Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity and DC Resistance.Turns Measurement ( through Toroidal Turns Test Platform) : -> TTPT-100 : 5 Turns ~ 1000Turns-> TTPT-1000 : 500 Turns ~ 10,000Turns
-
UFTS-CM_20Ch/ 20Ch -
Misum Systech Co., Ltd.
All of the lithium batteries need protection circuit module to prevent any loss of battery function capacity and explosion during over charge , over current or short to cause increased temperatures. This equipment is used to test and inspect a battery's voltage, current, charge, discharge PCM status, IR, and others.
-
DEM60C -
IBEKO Power AB
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
-
Applied Meters, a.s.
Three-phase static electricity meters AMT B1x-S(D)xxTE are determined for single-rate or double-rate active energy measurement in direct and indirect connection, displaying results on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio.
-
STATOGRAPH® Product Family -
Foerster Instruments, Incorporated
The STATOGRAPH product family is used for testing surface cracks with the help of eddy current sensors. Eddy current testing for material cracks requires the appropriate evaluation electronics and probes adapted to the testing task. Depending on the test situation and test object, the STATOGRAPH family of test instruments offers the right system for this purpose.
-
ST-1520 -
MRC ltd.
Capable of measuring earth voltage.2mA measuring current permits the testing of earth resistance without tripping earth leakage current circuit breakers in the circuit.Auto power off function.The timer operates automatically for approximately three to five minutes when the "push button switch" and "timer on button" are pressed together.
-
LM Series -
Koyo Electronics Industries co., ltd
Models in LM-2100 series equipped with LCR meter are designed to measure inductance and dissipation factor of the coil to which DC current is superimposed. Special circuit is built in to protect the LCR meter from surge voltage. Applied current can be step by step in the remote mode. Voltage application is impossible with the safety cover open.
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
PPX -
CKD Corporation
30mm compact 2-screen/3-color display pressure sensor.It is a digital pressure sensor packed with ease of use and high functionality such as a dual screen display that allows you to check the (current value) and (set value) of pressure at the same time, a three-color display, a setting content copy function, and three mode settings.