  • PXI BRIC8 FIBO Matrix Dual 12x2 3pin brkout

    40-595A-002 - Pickering Interfaces Ltd.

    The 40-595A is a matrix module based on the BRIC format that is designed for fault insertion applications in safety critical testing. As with other BRIC modules the matrix size can be scaled to suit the user application. The 40-595 has a very high current rating of 10 Amps, ideal for higher power systems, and can be used as a conventional matrix.

  • Low Noise Amplifier

    1010 - Dexter Research Center, Inc.

    A low noise, DC-coupled amplifier is packaged in a rugged, die-cast aluminum case with BNC connectors enabling input and output. Provides very low voltage noise and current noise in the critical region of 0.1 Hz to 10 Hz making this the ideal amplifier for thermopile detectors in sensitive systems design and laboratory experiments.

  • DC Power Supply, 0-120 V, 0-1.5 A, 180 W, GPIB

    N6700 - Keysight Technologies

    Keysight high performance DC power supplies offer speed and accuracy for test optimization. The single output, 200 W, GPIB 6641A-6645A provide fast, low-noise outputs; analog control of output voltage and current; fan-speed control to minimize acoustic noise; as well as parallel and series connections of multiple units.

  • IEC 61850 Solutions

    Megger Group Ltd.

    These IEC 61850 networks require specialised solutions to effectively verify that the substation is properly configurated and Megger has been providing such since 2009. For example, to capture the current data traffic and compare that with the specified and authorised data traffic helps to identify potential problems and in worst case, unauthorised data traffic by intruders.

  • Transformer Ratio Meters

    Handheld Turns Ratio & Winding Resistance Tester TWR-H - Amperis sl

    TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.

  • Multifunction Electrical Installations Meter

    MPI-502 - Sonel S.A.

    Short circuit loop parameters measurements:measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, *230 V/400 V, 240/415 V and frequency 45...65 Hz,*measurements of short circuit loop impedance with current 15 mA without tripping the circuit breaker.Testing the RCD breakers of AC, A types:*testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,*IA measurement*RE and UB measurement without tripping the circuit breaker,*extended RCD test function AUTO, with measurement of ZL-PE with current 15 mA - measurement of IA and tA during one RCD tripping.Detection of the replacement L and N in the socket and automatic conversion in the meter.Low voltage resistance measurements of protective circuits and junctions:*measurement of resistance with ±200 mA current*calibration of test leads - possibility of using any length of test leads,*low current resistance measurement with accoustic signalling

  • Single Phase AC Power Source

    APS51 Series - Twintex Electronics Co., Ltd

    ★ Full range adjustable output: Low 1-150V, High 150.1~300V, resolution 0.1V★ Output frequency: 45-250Hz★ Fast output key for 110V/220V and 50Hz/60Hz★ Panel lock function★ 3 sets memories for voltage and frequency settings★ Unlimited rotary knob for voltage and frequency adjustment, minimum step 0.001★ Strong overload capacity, overload 300% within 2s★ Withstand transient current 1.5 times of rated current within 0.1s★ Response time less than 20ms for 100% load and unload★ 5 digits high accuracy LED display for voltage, current, frequency, active power, power factor★ With soft-start function, set voltage rise time (0~99.999s), avoid damage by surge current during load start-up★ Over load, over current, over temperature and short circuit protections★ RS232 interface

  • Battery Tester

    G5.BT - Regatron AG

    The G5.BT series is bidirectional regenerative. It was developed specifically for testing energy storage devices and is suitable for use in laboratories and on test benches. The modular and finely graded G5.BT series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3. The G5.BT series has an outstanding current accuracy of <0.02% FS, an additional high-resolution current measurement range, and a fast current rise time in the 100 μs range. Ripple modulation, an integrated safety relay for PL c according to EN ISO 13849 and a powerful CAN multi-protocol interface (1 kHz, 16 bit) as well as functions to avoid reverse-polarity problems, current surges, and unwanted deep discharges make the G5.BT series the ideal, versatile battery module and battery pack tester.

  • Portable Electricity Meter Testers

    EE-120A-3S + EE-500V-3 - EMSYST Ltd

    The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. All types of electricity meters – mechanical or electronic, for active, reactive or apparent energy, single-phase or three-phase – can be tested with the Energy Standard. The following meter tests can be carried out with the EE Test System: Error Test, Register Test, No Load Test and Starting Current Test. Full analysis of the customer load can also be performed, if current clamps have been ordered. All test results ( maximum 3 Test Plans, 5 Manual Measurements and Customer Load Analysis) can be saved in one file. 100 saved files can be viewed on the LCD display or transferred to a PC via USB port.

  • Battery Charger-Analyzer for small battery systems (up to 10A-Hr)

    24-400xg - JFM Engineering

    The 24-400XG is an instrument designed to charge, trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.With its multiple modes of operation of Constant Current Charge (dual and single rate), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge (analysis), Resistance Discharge (analysis) and Full Discharge (deep cycle), the 24-400XG can satisfy the requirements of most small (0 to 10 A-hr) rechargeable battery systems.The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit (no load) and Overvoltage conditions.Two large LED digital meters permit the simultaneous monitoring of voltage and current, while eight indicator lights inform of the status of the operation.

  • Intelligent Battery Charger-Analyzer for Large Battery Systems

    SuperMasterCharger - JFM Engineering

    The SuperMasterCharger is an instrument designed to charge, trickle charge and analyze ( discharge ) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries. With its multiple modes of operation: Constant Current Charge ( dual and single rate ), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge ( analysis ), Resistance Discharge ( analysis ) and Full Discharge ( deep cycle ). The SuperMasterCharger can satisfy the requirements of most large ( 10 A-hr to 100 A-hr ) rechargeable battery systems. The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit ( no load ) and Over-voltage conditions. Two large LED digital meters permit the simultaneous monitoring of voltage and current, while eight indicator lights display the status of the operation.

  • Intelligent Battery Charger-Analyzer for Battery Systems

    SuperMini - JFM Engineering

    The SuperMini is an instrument designed to charge, trickle charge and analyze ( discharge ) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries. With its multiple modes of operation: Constant Current Charge ( dual and single rate ), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge ( analysis ), Resistance Discharge ( analysis ) and Full Discharge ( deep cycle ). The SuperMini can satisfy the requirements of most ( Up to 40 A-hr ) rechargeable battery systems. The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit ( no load ) and Over-voltage conditions. Two large LED digital meters permit the simultaneous monitoring of voltage and current, while eight indicator lights display the status of the operation.

  • 100 Watt Dynamic Measurement DC Source, 20V, 5A

    66332A - Keysight Technologies

    The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections. The Keysight 66332A Dynamic Measurement dc Source provides dynamic measurement and analysis of voltage and current waveforms. It is ideal for testing digital wireless communications products/components because it not only provides the power for testing, but also performs the peak current measurements required to characterize the pulsed current demands of these products.

  • General Purpose Low-side MOSFET Drivers

    Renesas Electronics Corp.

    Renesas' family of low-side FET drivers are very high-speed matched dual-drivers capable of delivering peak currents of 2.0 amps into highly capacitive loads and excellent at driving large capacitive loads with minimal delay and switching times. The high-speed performance is achieved by means of a proprietary "Turbo-Driver" circuit that speeds up input stages by tapping the wider voltage swing at the output. Improved speed and drive capability are enhanced by matched rise and fall delay times. These matched delays maintain the integrity of input-to-output pulse-widths to reduce timing errors and clock skew problems. This improved performance is accompanied by a 10 fold reduction in supply currents over bipolar drivers, yet without the delay time problems commonly associated with CMOS devices. Dynamic switching losses are minimized with non-overlapped drive techniques.

  • Ohmmeters

    GAO Tek Inc.

    GAOTek provides state of the art, professional grade Ohmmeters for sale to the United States, Canada and Globally. GAOTek Ohmmeters are portable instruments that accurately measure electrical resistance between two points on a circuit. The Ohmmeters have their own power supply through their own battery, and are needed when the two probes (red: positive side of circuit, black: negative side of circuit) are connected to the two points in the circuit where the desired measurement is to take place. The circuit is turned off, which is when the ohmmeter sends its own current through the circuit. Units of Ohms, symbolized by the Greek letter Ω (Omega), are used as a unit of measure when measuring electrical resistance. In accordance with Ohm’s law, when the current is passing through a circuit is at its maximum, the resistance is said to be the smallest.