40-614D-004 -
Pickering Interfaces Ltd.
The 40-614D-004 (PXI) and 42-614D-004 (PXIe) 8-bank, 8-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Magnicon GmbH
The SQUID series arrays are ideal for readout of TES sensors or as amplifier stage for discrete two-stage applications. Integrated bias resistors for TES or two-stage applications reduce wiring complexity. Various arrays with input inductances of 3 to 6 nH, input sensitivities of 17 to 23 µA/Phi0, and a current noise between 5 and 10 pA/sqrt(Hz) @ 4 K are available.
-
iTrans2 -
Teledyne Gas & Flame Detection
The iTrans2 infrared gas detector employs an intelligent electronics platform to provide one or two points of detection from a single head for maximum flexibility, superior performance and lower installation costs. With the optional HART Communication Protocol, the iTrans2 offers remote diagnostics, set-up or calibration by superimposing a high-frequency current across the industry standard 4-20mA analog line.
-
40-614D-003 -
Pickering Interfaces Ltd.
The 40-614D-003 (PXI) and 42-614D-003 (PXIe) 8-bank, 16-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
MD79 -
Matco Tools
*Provides readings for volts, amps and ohms required for automotive electrical system tests*Handy 35mm AmpTip clamp jaws ergonomically measure at jaw tip for small sized conductors up to 60A and regular current, and Hz measures at jaw center for regular conductors up to 600A*Records max, min and calculates average readings over time
-
RMS-1000 -
ECOPIA
Accurate and powerful performance. - Possible to get much accurate resistivity value by taking 8 raw data. - Good to check ohmic contact by flowing forward and reverse current.2. We provide various sample mounting board and probe head and tips.3. We have an optional item which can measure in variable temperature. - Room Temperature ~ 300dC.
-
Osborne Transformer Corp.
Osborne Potential Transformers (PT’s) are used to reduce higher system voltages to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when potential transformers are to be used for power measuring applications.
-
4014 -
Red Phase Instruments Australia Pty Ltd.
The Model 4014 integrates four ammeters for the direct and simultaneous reading of C.T. secondaries up to 10A during the setting up or checking of protection systems while they are in service with normal 50/60Hz primary currents flowing. The two terminals of each channel of the Model 4014 are connected in series with the C.T. secondary with all other equipment in the loop or directly across the C.T. secondary.
-
MT-2018 -
Prokit's Industries Co., Ltd.
Complied with 2008 CE safety standardMirrored Aluminum dial plate20k/V DC & 9,k/V AC input sensitivityOverload and mis-used protectionAdjustable back tilt device with hook-up designRobust protective holster alongsideResistance, Current & Voltage measurementsTransistor hFE TestBattery TestTest leads, batteries, fuse and user's manual includedIdeal for using in the fields of lab, school, home applications and more
-
openQCM
The sensor is a surface sensitive quartz crystal capable of measuring phenomena at molecular scale. It works in vacuum, air and liquid environments. The QCM sensor is based on the piezoelectric properties of the quartz crystal. The application of an alternating current causes the mechanical vibration of the quartz crystal in the MHz range. The QCM technique measures the variations in quartz frequency for measuring the mass variations on its surface.
-
ViTec Co. Ltd
The acceptance test station consists of a personal computer - the workstation of the operator of the testing station, contact mechanisms, as well as current and voltage sensors. The station allows to test up to 10 electric motors of various types simultaneously. The operator of the testing station indicates the test sites at which the engine tests will be conducted, their type (from the database), serial numbers and a set of tests.
-
SCR ELEKTRONIKS
The HWI test indicates a materials resistance to ignition when exposed to abnormally high temperatures resulting from a component failure such as a conductor carrying far more than its rated current. HWI performance is expressed as the mean number of seconds required to ignite a specimen when wrapped with an energized non-chrome resistive wire that dissipates a specified level of energy.
-
CSM Products, Inc.
The HV Breakout Modules (BM) are specifically designed for safely measuring directly from HV voltage power cables. Currents and voltages are measured directly and the raw data is acquired at up to 2 MHz per channel. With the Vector eMobilityAnalyzer software, which is optimally paired to the CSM HV Breakout Modules, real time power analysis is also possible.
-
PS-200 -
CoolMax Technology Inc.
It is important to keep your graphic cards powered, but you want to make sure that your graphic cards aren’t overpowered. Not all power supply units have power surge protection, so your graphic cards may be vulnerable to damages from over voltage or over current. Protect your graphic cards now with the new PS-200.
-
40-614D-023 -
Pickering Interfaces Ltd.
The 40-614D-023 (PXI) and 42-614D-023 (PXIe) 26-bank, 4-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.