Showing results: 3346 - 3360 of 5366 items found.
-
1820 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
4120 ER -
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.
-
ECLIPSE -
HT Italia Srl
ECLIPSE has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/EN61010-1. The clamp is provided with a display with 6000 measuring spots with backlight and bargraph to allow for a simple reading even in poorly lit environments.
-
LAB / SLR -
ET System Electronic GmbH
*Linear laboratory power supply*Integrated electronic load*Automatic range selection*Linear regulated DC source with automatic range selection*Built-in electronic load*Short-term peak load operation 240 or 480 watts*Protection against short circuit, overload and overtemperature*Double current / double voltage through "autoranging"*Fast control times approx. 250µ
-
GNATcoverage -
AdaCore Technologies, Inc.
GNATcoverage performs coverage analysis on both object code instruction and branch coverage and Ada and C language source code statement, decision and Modified Condition/Decision Coverage (MC/DC). Unlike most current technologies, the tool works without requiring instrumentation of the executable. Instead, it runs directly on an instrumented version of GNATemulator, a lightweight and efficient emulator tool. GNAT Pro add-on.
-
Trialon Corp.
PCBs are constructed of a variety of materials such as glass, ceramic, copper, solder and Teflon. Trialon has the equipment and experienced staff to perform this difficult analysis. Our state-of-the-art materials analysis lab located in Auburn Hills, MI is managed by a Ph.D with over 20 years of hands-on experience in root cause failure analysis of design, material and process for current and future products.
-
Edmund Optics Inc.
Detectors are used to measure the illumination of a light source for a number of optical or spectrometry applications. Detectors consist of arrays of photodiodes or photodetectors that transmit electrical current when excited by collision from photons. Detectors enable the measurement of important light characteristics that are not conveniently acquired in other ways. A selection of photodiodes is also available with linked amplifier capabilities for easier, more precise measurement capacities.Detectors
-
DMT 2004 -
Monacor International GmbH & Co. KG
*2000 digit resolution*Voltage measurement up to DC/˜ 250 V*Current measurement up to DC/˜ 10 A*Resistance measurement up to 2 MΩ*Battery test for 9V block and 1.5V cells*Acoustic continuity test*diode test*Data hold (measured value memory)*LC display with switchable background lighting*overload protection*Supplied with test leads
-
STHVP/STHVE -
HK Film Capacitor Ltd
High Voltage Pulse Current for medium frequency applicationHigh Voltage DC / AC Voltage applicationCapacitor can be discharged at rated voltage directly without any protective component and with ambient Temperature up to +105CHigh Voltage Decoupling and SnubberingVoltage MultiplierInduction heatingAct as discharge capacitor to trigger laser, X-Ray and Tesla CoilFor high voltage capacitor bank or arrayHigh Voltage Power Supplies
-
Model PZD2000A -
TREK, INC.
The Trek Model PZD2000A is a wide bandwidth high-voltage power amplifier used for precision high power applications. This new addition to the Trek power amplifier product line is designed to provide precise control of output voltages in the range of 0 to ±2 kV DC. Features include an output current range of 0 to ±400 mA and an excellent large signal bandwidth capability.
-
MS3112 -
Metal Samples Company
The Hydrogen Penetration Monitoring System™ provides a method for directly measuring the rate of hydrogen migration through a vessel or pipe wall. This method actually measures the penetration current set up by the hydrogen as it moves through the steel. By sensing and recording this data directly from the pipe wall, this system offers valuable data which can only be indirectly inferred by other methods.
-
Bee Instruments
Inductive Proximity Switches, self contained, depend on the output of an oscillator for their operation. The oscillator resonant circuit uses an open core coil to produce a concentrated high frequency electromagnetic (RF) field, which emerges from the active surface of the sensor. If a metal target (or other electrically conductive material) enters this field, eddy currents will be induced in it, causing the resonating oscillator to be damped.
-
HH2107 -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.5%). Jumbo LCD display 2000 count, 21.8mm figure height. Manual Ranging at your choice (30 Range). High Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 20MΩ. Diode test, audible continuity check and transistor test
-
HH2108 -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.8%). Jumbo LCD display 2000 count, 26mm figure height. Manual Ranging at your choice (30 Range). High Voltage test up to AC 500V and DC 500V. Higher Current test up to 20A AC/DC. Resistance test up to 20MΩ. Erequency test range from 10Hz to 1999Hz
-
8012H -
Sealevel Systems, Inc.
Optimized for sensing 24V inputs, the 8012H Low Profile PCI digital interface provides eight Reed relay outputs (SPST) and eight optically isolated inputs supporting 10-30V. Reed relays are well suited for low current applications. The relays are normally open, and close when energized. The board is MD1 Low Profile and Universal Bus (3.3V and 5V) compatible.