Filter Results By:

Products

Applications

Manufacturers

Showing results: 3376 - 3390 of 5270 items found.

  • 256 Channel Power Supply

    IDPS750 - Salland Engineering

    Salland Engineering’s Independent Device Power Supply (IDPS) can expand your existing Automated Test Equipment (ATE) with up to 256 independent DPS sources to increase parallel testing. It offers Force Voltage (FV) and Measure Current (MI) that can be used for continuity tests, parametric supply current (IDD) and quiescent supply current (IDDQ) measurements or simply for powering devices under test. The IDPS750 is targeted to reduce test costs for a wide range of applications including smart cards, memory, microprocessors and FPGA’s. Its design makes it useful in applications where many resources are required, or were the original ATE supplies do not meet your required specifications.

  • LED Test Programmable DC Electronic Load

    IT8912E Series - I-TECH Electronic Co., Ltd

    IT8900 series high accuracy LED specific testing electronic loads can simulate the real output of LED lights with different characteristics.Their specific circuit can realize CR-LED mode, adjustable frequency, duty ratio PWM dimming output port (frequency: 20Hz-2KHz), I-pp/I-max measurement function can test current ripple and start up surge current of LED constant flow source. Voltage and current testing speed can reach 50KHz. IT8900 series provides CR-LED / CC / CV + CC / CR /CW and other working modes, built-in USB / RS232 / GPIB communication interface. Widely used in LED driver power dimming test.

  • HMM+™ Tester

    Model 4702 - Barth Electronics, Inc

    The Model 4702 HMM+™ is a completely new tester primarily intended for device level testing and produces a current waveform as specified in the IEC-61000-4-2, from a 50 ohm source impedance system.*This tester provides device level test data that allows users to evaluate the IEC current waveform protection level of their devices. We included failure identification by leakage current increases in the 4702 tester so precise pass/failure levels can be closely measured.*The 4702 HMM+™ provides a new and improved test connection method for making quantifiable and repeatable device level HMM measurements.*Convenient, precise, repeatable operation*Computer controlled for automated testing

  • TOV Test System

    Shanghai Guantu Technology Co., Ltd.

    1. Safety protection: traffic light indication status, emergency stop and interlocking of the test product door2. Equipped with a computer, set the TOV power supply parameters through the software interface, and automatically test3. Equipped with alarm function, equipped with emergency brake switch, equipped with safety cover and door switch4. The computer interface displays real-time voltage and current data5. Automatically draw voltage and current waveforms, and can save the waveforms as BMP format pictures, which is convenient for editing experiment reports.6. Automatically record test time, test current, test voltage, etc., and save the recorded data to files7. Installation method: cabinet installation.

  • Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.

    72-2985 - Tenma

    The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.

  • DC Power Supply

    62000H Series - Chroma ATE Inc.

    The 62000H Series includes 14 different models ranging from 5KW to 15KW, with current range up to 375A and voltage range up to 1000V. The 62000H can easily parallel up to ten units capable of 150KW with current sharing for bulk power applications, for example, battery bank simulation of 450V/150A/67.5KW for electric vehicle and military use. There are 100 user programmable input status on the front panel for automated test application and life cycle ON/OFF test. In addition, the 62000H has a 16 bit digital control with bright vacuum fluorescent display readout. The 62000H series DC power supplies are very easy to operate either from the front panel keypad or from the remote controller via USB / RS232 / RS485 / APG (Standard) and GPIB & Ethernet (optional). Its compact size with 3U only can be stacked on a bench in a standard rack without any difficulty.

  • 16 Thermocouples/RTD Ch

    APCI-3200-16 - TEAM SOLUTIONS, INC.

    18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel16 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 8 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated

  • 4 Thermocouples/RTD Ch

    APCI-3200-4 - TEAM SOLUTIONS, INC.

    18-bit resolution, 16-bit accuracyEach channel can be configured either for thermocouples/RTD or as an analog voltage input channel4 analog input channels for thermocouple typesJ, K, T, E, R, S, B, N - or 2 diff. analog input channels for the acquisition of resistance temperature detectors (Pt100)- or 16 SE/8 differential analog voltage input channels, ± 2.5 V8 independent current sources for resistance temperature detectors (RTD) and one current source for cold junction compensationCold junction compensation (on separate screw terminal board PX 3200)Gain and offset calibrationLinearisation through table and calculation for the thermocouple types J, K, T, E, R, S, B, N and RTDsProgrammable gain16-bit accuracy with sample rates of 20, 40, 80 or 160 Hz (other rates on request)4 digital input channels, 24 V and 3 digital output channels, open collector, isolated

  • 50Hz-100kHz LCR Meter

    11022/11025 - Chroma Systems Solutions, Inc.

    0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver

  • High Voltage Probes To Measure Primary Waveforms With A Power Analyzer

    Volt Litewire - SensorLink

    The Litewire is a true RMS meter designed for use by electric utilities to sense currents or voltage waveforms from the primary side of their distribution networks.

  • Circuit Breaker Test System

    TDR900 - Manta Test Systems

    It operates and records a circuit breaker’s contact timing, motion, velocity, main contact engagement & synchronization, trip and close coil initiation and currents.

  • Measurement

    Power Meter - ZETLAB Company

    Power Meter is used for determining the power of the electrical current coming to the input channels of ADC modules and FFT spectrum analyzers, or that of the electromagnetic signal.

  • Digital Electrical Network Analyzer

    1826 NA - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.

  • CDNs

    M Series - Com-Power Corporation

    Coupling Decoupling Networks are recommenced for all power supplies connections. The distubance signals are coupled to each conductor in the supply lines according to EN 61000-4-6 standard. The standard M series CDNs have a current rating of 25 Amps. Com-Power CDNs are available for power supplies from 1 to 5 conductors. These CDNs cover the frequency range of 150 kHz - 230 MHz.

  • CT/PT Analyzer

    KINGSINE Electric Automation Co., Ltd.

    1, Consisting of Function modularization design and plug-in frame, each module contains self-calibration function, plug and play when change module, easy to maintain for customer.2, Adopt TFT LCD display screen with clear and beautiful software interface design, user can operate easily3, AC/DC current input for wide range only, satisfy all power supply standard requested.

Get Help