Showing results: 331 - 345 of 5316 items found.
-
-
INA169 -
SparkFun Electronics
The INA169 is a “high-side current monitor,” which means that you place a resistor (a “shunt resistor”) on the positive power rail and the INA169 measures the voltage drop across that resistor. The INA169 outputs a small current based on the measured voltage drop. If you place a resistor from the output of the INA169 to ground, you can measure the voltage at the output.
-
Analog Devices Inc.
Analog Devices high speed (> 50 MHz) current feedback op amps enable you to operate at higher speeds. Current feedback op amps traditionally have wider bandwidths and higher slew rates than voltage feedback amplifiers and do not feature a gain bandwidth restriction associated with voltage feedback op amps.
-
Monitran Ltd.
Proximity sensors work on the eddy current principle. A proximity system consists of an eddy current probe, extension cable and driver. A high-frequency RF signal is generated by the driver, sent through the extension and probe cables and radiated from the probe tip. The tip consists of a precision wound copper coil inside a chemical and temperature resistant PEEK case.
-
228 -
Simpson Electric Company
Test for dangerous leakage current with the Simpson Model 228, designed to meet the latest UL, IEC, and ANSI specifications. The 228 detects both AC and DC leakage current and simulates human response at three different levels -- reaction, let-go, and burn hazard. Each Model 228 comes with test leads with alligator clips, manual, and batteries.
-
1625A -
Ballentine Laboratories, Inc.
The BLI 1625A is a multiranging, high accuracy, active current shunt, for use in making NIST traceable measurements of currents from 10 microamperes to 100 Amperes. Very high measurement stability has been achieved in our shunt design by using special alloys, compensated by a proprietary Ballantine process to minimize temperature coefficient effects.
-
HK Film Capacitor Ltd
HK Film Capacitors offer a selection of High AC Current Capacitors ( continuous duty) with Temperature up to +105C
-
DC Connect -
Listen Inc
DC Connect enables measurement of current consumption of battery operated and other low voltage devices such as hearing aids
-
Keysight Technologies
The dedicated Current Sensors measure from 100 pA level dynamic current up to 10 A with a maximum of 200 MHz bandwidth. The mainframe acquires the signal from the sensors by a maximum of 1 GSa/s sampling speed and 14-bit and 16-bit wide dynamic range. This combination allows you to measure quite wide range of dynamic current, for example, from standby/sleep state to active state, at a single measurement. In addition, the wide bandwidth and the high speed acquisition enable you to measure high speed pulse response even less than 100 ns previously very difficult with existing instruments.
-
HFCT Ø 140mm -
Techimp HQ S.r.L
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Unitech Scales And Measurements Pvt. Ltd
Pressure to Current (P to I ) Trainer:This setup comprises of pressure chamber fitted on a base board. A pressure transducer and bourdon pressure gauge are fitted to the chamber. Digital pressure indicator with transmitter output is provided to display the pressure sensor by the pressure transducer. Transmitter output 4 to 20mA can be measured by a current meter. Foot air pump is provided to build the pressure.
-
Unitech Scales And Measurements Pvt. Ltd
Current to Pressure Trainer. This setup comprises of a I to P converter fitted on a base. Two pressure gauges are fitted one at the input side and the other at the output of the I to P converter. A current source with digital display is provided to excite the I to P converter. A constant air supply should be provided to the system at 20 PsI Pressure from a standard compressor.
-
TCS -
RARA Electronics Corporation
These components are four-terminal. bus-bar, metal strip current shunts. Assembled using electron beam welding. These units can handle 15W of continuous power and a maximum current of 350A 90.1mohm). Also they can absorb a high pulse power rating and have very low inductance. They also feature excellent long term stability, less than 100ppm/C TCR, and have excellent frequency characteristics.
-
TGP-4810 -
Gemini Data Loggers Ltd.
A data logger, housed in a rugged case, supplied with a Chauvin Arnoux Current Clamp . This unit is ideal for mains and power consumption monitoring.
-
Iris Power LP
Shaft monitoring to indicate high voltage and current on the motor or generator from poor shaft grounding performance prior to bearing failures.