Showing results: 331 - 345 of 5270 items found.
-
HK Film Capacitor Ltd
HK Film Capacitors offer a selection of High AC Current Capacitors ( continuous duty) with Temperature up to +105C
-
DC Connect -
Listen Inc
DC Connect enables measurement of current consumption of battery operated and other low voltage devices such as hearing aids
-
Keysight Technologies
The dedicated Current Sensors measure from 100 pA level dynamic current up to 10 A with a maximum of 200 MHz bandwidth. The mainframe acquires the signal from the sensors by a maximum of 1 GSa/s sampling speed and 14-bit and 16-bit wide dynamic range. This combination allows you to measure quite wide range of dynamic current, for example, from standby/sleep state to active state, at a single measurement. In addition, the wide bandwidth and the high speed acquisition enable you to measure high speed pulse response even less than 100 ns previously very difficult with existing instruments.
-
HFCT Ø 140mm -
Techimp HQ S.r.L
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
TCS -
RARA Electronics Corporation
These components are four-terminal. bus-bar, metal strip current shunts. Assembled using electron beam welding. These units can handle 15W of continuous power and a maximum current of 350A 90.1mohm). Also they can absorb a high pulse power rating and have very low inductance. They also feature excellent long term stability, less than 100ppm/C TCR, and have excellent frequency characteristics.
-
TGP-4810 -
Gemini Data Loggers Ltd.
A data logger, housed in a rugged case, supplied with a Chauvin Arnoux Current Clamp . This unit is ideal for mains and power consumption monitoring.
-
Iris Power LP
Shaft monitoring to indicate high voltage and current on the motor or generator from poor shaft grounding performance prior to bearing failures.
-
Model 65A -
Telebyte, Inc.
FEATURES: Active/Passive Loops; 20 or 60 mA. Operation; DC To 19.2 KBPS; Half/Full Duplex; Optically Isolated; DTE/DCE Selectable. The Model 65A is a small, versatile, RS-232 to Current Loop Converters for use with teletypes or computers providing local terminal input via a 20mA. (or 60 ma.) current loop. The Model 65 includes a wall mounted transformer and internal power supply circuitry.
-
Fivestar HV Testing Equipment Co., Ltd.
Impulse current test systems are mainly used for testing transmission and distribution systems against the effects of direct or indirect lightning strokes or against electromagnetic interference effects. Primary application of impulse current test systems is the testing of surge arresters, nowadays mainly of the metal-oxide type (MOA) and surge protection devices (SPD). Now they are also widely used to test vehicles, aircrafts, and military applications.
-
Teledyne Marine Webb Research
Only Teledyne Webb Research offers the APEX - EM, a spinning float that directly measures water motion through induced electromagnetic currents.
-
GPTN -
Holding Informtest
The module is intended for use as part of information measuring systems based on the VXI-bus trunk. The module is designed to generate constant current or constant voltage.
-
LC-2R -
Lumetronics
The test for leakage current in mains operated equipmentis one of the most primary & important tests to verify thequality & electrical safety characteristics of products.
-
HK Film Capacitor Ltd
Both series can be customized as Low Voltage High Capacitance High Current Capacitors.We can customize Snubber Capacitor as Box type and support other parameters.For 250Vac~900Vac / 400Vdc~1,350Vdc and with higher Current requirement, please refer to our AC/DC Power Capacitors.Different applications can have very different capacitor electrical and mechanical profile requirements.Please feel free to send your application details for a suggestion and quotation.
-
LCT 2 -
Shanghai Powoo Industry Develop Group Limited
- suitable for a wide range of current (1.5A~120A); - there are standard holes on the primary lead wire; therefore, can be fixed at the terminal of the electricity meters with standard bolts, which makes it both firm and convenient; - the primary lead wire is highly customer-tailored with more than 300 specifications; - encapsulated with epoxy resin to ensure strong insulation ability; - linear output current, high precision; - AMB anti-combustion plastic casing.
-
KCTS-8000 -
Knopp Incorporated
The Knopp Current Transformer Testing System (Type KCTS-8000) is designed to measure the accuracy of instrument transformers having 1 or 5 ampere secondaries and primaries of up to 8000 amperes. The system uses a high accuracy multi-range current transformer as a reference standard. All ANSI standard burdens are included. The phase angle and ratio errors of the transformer-under-test (TUT) are measured by the built-in Knopp Automatic Transformer Comparator.