Showing results: 3451 - 3465 of 5323 items found.
-
cPCIS-2632 Series -
ADLINK Technology Inc.
*3U CompactPCI® backplane with seven peripheral slots and one system slot*Temperature, voltage, and fan monitoring LEDs*Supports current sharing on +5 V, +3.3 V, and +12 V*1 + 1 hot swappable 250 W + 250 W CompactPCI® power supplies*PICMG® 2.11 47-pin power interface*Hot-swappable cooling fans & filter
-
ATHENA IV -
Diamond Systems Corp
Each generation of Athena maintained the same physical shape and most of the I/O connectors and features of the previous generations, while updating key features to stay current with the state of the art. In this way the Athena platform has maintained a low-impact migration path for customers with extended product lifecycles that outstrip the lifetimes of the CPU. Many customers have been able to maintain their products for up to 16 years as a result.
-
RS-8K -
Taylor Dynamometer, Inc.
Taylor Dynamometer’s RS-8K Towing Dynamometer is designed fortesting today’s mid-sized cars and SUVs. The RS-8K is built with an allaluminum frame, an aerodynamic body and rides on an independent,air ride suspension and uses an eddy current absorber with specialhigh temperature coils to absorb energy. The RS-8K is poweredby an industrial generator, so unlike battery/alternator TowingDynamometers, there are no lead-acid batteries to charge and testingtime is unlimited at low speeds.
-
Maxi-Burn -
MaxiTest LLC
The MaxiBurn Tube Preheater is a 2U rack mountable or bench top unit for heating 30 Octal Base Tubes. Designed for continuous use heating standard power pentodes to normalize their characteristics before testing or matching the MaxiBurn powers the tube filaments and drives a nominal plate current through each tube. Normal function of each tube is indicated by a glowing LED associated with the tube.
-
Loc3 5W -
Vivax-Metrotech Corp
The 5-Watt broadband transmitter has selectable induction and direct connection frequencies from 98Hz to 200kHz, SD mode (Signal Direction), fault find and true resistance measurement up to 1 Mohm. The two inch by one-inch dot matrix display with LED backlight shows output current, connection type, volts, resistance, frequency, volume, battery condition and high voltage warnings.
-
Loc3 10W -
Vivax-Metrotech Corp
The 10-Watt broadband transmitter has selectable induction and direct connection frequencies from 98Hz to 200kHz, SD mode (Signal Direction), fault find and true resistance measurement up to 1 Mohm. The two inch by one-inch dot matrix display with LED backlight shows output current, connection type, volts, resistance, frequency, volume, battery condition and high voltage warnings.
-
5000AG -
KestrelMeters.com
The Kestrel 5000AG is designed to meet the needs of livestock, agriculture and animal health professionals. Producers, growers, veterinarians, and consultants in every field of agriculture will gain vital information regarding micro-climate conditions needed to maximize performance and profitability. This lightweight, handheld, multi-function meter can be used inside and out for spot measurement of current conditions and also tracks and logs over 10,000 sets of time-stamped data.
-
Traceable Products
Ideal for recording ambient changes in lab, monitoring conditions affecting sample analysis, and assisting in prediction of weather changesUnit includes a barometer, thermometer, clock, altitude adjustment, and weather symbol forecasting symbolsAdjustable altitude compensation from –900 to 3600 feet (–300 to 1200 meters)Barometric trend shows current reading, previous 1, 3, 6, and 12-hour readings in bar chart f
-
mks Ophir
Photodiode sensors have a high degree of linearity over a large range of light power levels: from fractions of a nanowatt to about 2 mW. Above that light level, corresponding to a current of about 1 mA, the sensor saturates and reads erroneously low. Therefore, most Ophir PD sensors have a built-in and removable attenuator allows measurement of up to 3 W without saturation.
-
DATASTICK2 -
Com-Ten Industries
The system DATASTICK allows you to save you data on a USB stick in one click, whether you are doing your measurement indoor or outdoor on the field, we propose you a complete mobile solution. All data, results and curve are saved on your USB stick, no more needs of a computer. Connect the DATASTICK to your current gauge CENTOR TOUCH through a dedicated cable.
-
MT1000 And MT2000 Series -
Maury Microwave Corporation
The MT1000 and MT2000 mixed-signal active load pull systems are the best commercially proven solutions capable of performing load pull at high speeds of up to 1000 impedance/power states per minute with no limitation on Smith Chart coverage, under the following conditions:Single-tone CW and pulsed-CW RF signalDC and pulsed-DC biasTime-domain NVNA voltage and current waveforms and load linesFrequencies between 1 MHz and 40 GH
-
ficonTEC Service GmbH
An important aspect of the development and manufacture of laser diodes is the so-called laser diode characterization, or laser IV curve. By applying increasing current to the laser diode so it that emits light, the optical output is measured together with the voltage drop across the diode element. The resulting LIV curve reveals important clues about the quality of manufacture and the performance of the laser diode, enabling a pass/fail decision to be met.
-
Chroma Systems Solutions, Inc.
The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enable the Chroma 16502 can be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.
-
WERA -
ASL Environmental Sciences
The WERA system (WavE RAdar) is a shore based remote sensing system using the over the horizon radar technology to monitor ocean surface currents, waves and wind direction (Gurgel, 1999). This long range, high resolution monitoring system operates with radio frequencies between 4 and 50 MHz. A vertical polarized electromagnetic wave is coupled to the conductive ocean surface and follows the curvature of the earth.
-
Equip-Test Kft.
40 POL low resistance pylon, 40 POL signal pylon, 85 POL signal pylon, 102 POL Signal Pylon, 136 POL signal pylon, 170 POL low resistance pylon, 170 POL signal pylon, high current pylon blocks, optical pylon blocks, pneumatic pylon blocks, radio-frequency pylon block, & usb pylon blocks