Showing results: 346 - 360 of 5270 items found.
-
KCTS-8000 -
The Eastern Specialty Company
The Knopp Current Transformer Testing System (Type KCTS-8000) is designed to measure the accuracy of instrument transformers having 1 or 5 ampere secondaries and primaries of up to 8000 amperes. The system uses a high accuracy multi-range current transformer as a reference standard. All ANSI standard burdens are included. The phase angle and ratio errors of the transformer-under-test (TUT) are measured by the built-in Knopp Automatic Transformer Comparator.
-
TV-4804 -
Gemini Data Loggers Ltd.
The TV-4804 measures current from 0 to 25mA DC and can be connected to a variety of industry standard sensors enabling the logging of a wide range of process parameters.
-
-
TH1778AS -
Changzhou Tonghui Electronic Co., Ltd.
■ Test Frequency: 0Hz - 2MHz ■ Provide 0~20A of constant current output, and must be controlled by TH1778A ■ Support 6 machines on line at most and
-
RCM Blue -
Aanderaa Data Instruments AS
A self-recording dedicated current meter with Bluetooth for communications and data retrieval - now with the possibility to integrate a pressure sensor!The RCM Blue is a self-recording Current Meter which also measures water temperature in salt or fresh water, and a battery container with battery capacity up to 70Ah. .The Doppler Current Sensor is an upgraded version of the proven SeaGuard ZPulse sensor. The RCM Blue instrument configuration and data retrieval is done via Bluetooth which eliminates the need to open the pressure case for repeated deployments.RCM Blue has now been upgraded with the possibility to integrate a pressure sensor with a 0,01% accuracy. This simplifies your work significantly as you will know exactly where you are in the water column.
-
P-5000 -
The Eastern Specialty Company
The P-5000 transformer is a laboratory standard. The unit’s excellent accuracy and the Knopp One-to-One calibrating feature make this precision transformer well-suited as a standard for calibration work. This transformer can provide a very accurate determination of the ratio and phase angle characteristics of current instrument transformers having ratios from 5 to 5,000 amperes. This transformer also can accurately extend the range of a 5 ampere ammeter or wattmeter to cover all current values up to 5,000 amperes.
-
ICMS -
Dr. Strauss Messtechnik GmbH
The Impulse Current Measuring Shunts ICMS are new designed tubular shunt types with best response behavior to match the high performance of the TR-AS digital recorder for comparative current measurements. A 1st partial response time less than 10ns and a settling times less than 20ns show the advantage of these shunts. They show no initial overshoot peak, no oscillations and do not need compensation box to optimize the transient behavior as known from e.g. cage shunts.
-
695 -
Electronic Specialties Inc.
Great tool for accurate measurement of low current. Use with your graphing meter or lab scope to view current waveforms on fuel injectors, fuel pumps, primary ignition coils and more. Also works very well with digital multimeters. Resolution of 10 milliamps is low enough for most parasitic drain testing. In addition, the clamp opening of 1/2 inch is large enough to clamp over most negative battery cables for those parasitic drain tests.
-
DC1000A -
Voltech
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.
-
DU2316/2317 -
Delta United Instrument Co., Ltd.
Leackage Current range display: 0.0001uA ~ 20.00mAAutomatic or Manual trigger with CHARGE/TEST/DISCHARGE100 sets of memory, can be saved test parameter and comparator setting, easy to use.Cover up free, system firmware upgrade can be update via RS-232, easy to maintenanceHi / Lo current limit setting & PASS/FAIL judgment240*64 Graphic LCD display, can be read the reading clearly and easier.User friendly programmable interface, easy to useProvided RS-232C and Handler combinatorial interface option, to meet your needed
-
Vanguard Instruments Company, Inc.
The EZCT-2000C is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C has the following outstanding features that can greatly increase productivity and save time during the commissioning stage:
-
MIZ-21B -
Zetec, Inc.
Our MIZ-21B handheld eddy current tester is a powerful handheld tester on the market for testing cracks, heat damage and corrosion. The MIZ-21B incorporates dual-frequency and digital conductivity testing with nonconductive coating thickness measurement.
-
JYQ -
Kingrun Instrument Co., Ltd.
Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.
-
LAD-1100 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Selectable measuring range 30mA~30A with CT ratio 10:1 and 30A~3000A with CT ratio 100:1.●φ110mm CT window, possible to measure from leakage to big current up to 3000A.
-
TGPR-0800 -
Gemini Data Loggers Ltd.
A current input data logger that is supplied uncased so that it can be built into custom applications.The TGPR-0800 can be used to record the output from a number of industry standard 4-20mA sensors. Common applications include pressure and flow rate monitoring.